Surface analysis of study models generated from OrthoCAD and cone-beam computed tomography imaging

被引:38
|
作者
Lightheart, Kurtis G. [1 ]
English, Jeryl D. [1 ]
Kau, Chung H. [2 ]
Akyalcin, Sercan [1 ]
Bussa, Harry I., Jr. [1 ]
McGrory, Kathleen R. [1 ]
McGrory, Kevin J. [1 ]
机构
[1] Univ Texas Houston, Hlth Sci Ctr, Sch Dent, Dept Orthodont, Houston, TX 77030 USA
[2] Univ Alabama Birmingham, Sch Dent, Dept Orthodont, Birmingham, AL USA
关键词
DIGITAL MODELS; PLASTER MODELS; SPACE ANALYSIS; ACCURACY; RELIABILITY; INDEX; VALIDITY; TOOTH;
D O I
10.1016/j.ajodo.2011.12.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this research was to determine the accuracy of digital models generated by cone-beam computed tomography and compare it with that of OrthoCAD models (Cadent, Carlstadt, NJ) for orthodontic diagnosis and treatment planning by using surface area analysis. Materials: Two sets of maxillary and mandibular digital models of 30 subjects were obtained. The models were made from impressions scanned with OrthoCAD and by conversion of related cone-beam computed tomography files. Each patient's matched pairs of maxillary and mandibular models were superimposed by using a software program and a best-fit algorithm; surface-to-surface analysis was then performed. The average linear differences between the 2 files at all points on the surfaces were measured, and tolerance levels of 0.25, 0.5, 0.75, 1.0, 1.25, and 1.5 mm were set to determine the surface correlation amounts between the 2 files. Additionally, 6 linear measurements from predetermined landmarks were also measured and analyzed. Results: The average maxillary model linear difference was 0.28 to 0.60 mm, whereas the average mandibular model linear difference ranged between 0.34 and 0.61 mm. Greater than a 90% surface correlation was obtained on average at 1.00 mm in the maxillary models and at 1.25 mm in the mandibular models. The mean differences obtained from the linear measurements of the maxillary and mandibular models were 0.071 and 0.018 mm, respectively. Conclusions: Surface-to-surface analysis of OrthoCAD and digital models generated by cone-beam computed tomography pointed to a fair overlap between the protocols. The accuracy of digital models generated by cone-beam computed tomography is adequate for initial diagnosis and treatment planning in orthodontics. (Am J Orthod Dentofacial Orthop 2012;141:686-93)
引用
收藏
页码:686 / 693
页数:8
相关论文
共 50 条
  • [41] Prevalence of Artifacts in Cone-Beam Computed Tomography: A Retrospective Study
    Mahesh, K. P.
    Deshpande, Prasannasrinivas
    Viveka, S.
    JOURNAL OF INDIAN ACADEMY OF ORAL MEDICINE AND RADIOLOGY, 2022, 34 (04) : 428 - 431
  • [42] Cone-Beam Computed Tomography Study of Mandibular Condylar Morphology
    Yalcin, Eda Didem
    Ararat, Emine
    JOURNAL OF CRANIOFACIAL SURGERY, 2019, 30 (08) : 2621 - 2624
  • [43] General surface reconstruction for cone-beam multislice spiral computed tomography
    Chen, LG
    Liang, Y
    Heuscher, DJ
    MEDICAL PHYSICS, 2003, 30 (10) : 2804 - 2821
  • [45] Evaluating the mandible with cone-beam computed tomography
    Stratemann, Scott A.
    Huang, John C.
    Maki, Koutaro
    Hatcher, David C.
    Miller, Arthur J.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (04) : S58 - S70
  • [46] Simple ROI Cone-Beam Computed Tomography
    Maass, Clemens
    Knaup, Michael
    Sawall, Stefan
    Kachelriess, Marc
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3161 - 3168
  • [47] Operational principles for cone-beam computed tomography
    Hatcher, David C.
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (10): : 3S - 6S
  • [48] Cone-Beam Computed Tomography: Beyond Diagnostics
    Perel, Morton L.
    IMPLANT DENTISTRY, 2015, 24 (04) : 367 - 367
  • [49] High-Biofidelity Biomodel Generated from Three-Dimensional Imaging (Cone-Beam Computed Tomography): A Methodological Proposal
    Hernandez-Vazquez, Rosa Alicia
    Urriolagoitia-Sosa, Guillermo
    Marquet-Rivera, Rodrigo Arturo
    Romero-Angeles, Beatriz
    Mastache-Miranda, Octavio Alejandro
    Vazquez-Feijoo, Juan Alejandro
    Urriolagoitia-Calderon, Guillermo
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2020, 2020 (2020)
  • [50] Cone-Beam Computed Tomography (CBCT) to Computed Tomography (CT) Image Translation with Perceptual Loss to Eliminate Cone-Beam Artifacts
    Yoo, S.
    Choi, B.
    Park, I.
    Kim, J.
    Kim, H.
    MEDICAL PHYSICS, 2021, 48 (06)