Surface analysis of study models generated from OrthoCAD and cone-beam computed tomography imaging

被引:38
|
作者
Lightheart, Kurtis G. [1 ]
English, Jeryl D. [1 ]
Kau, Chung H. [2 ]
Akyalcin, Sercan [1 ]
Bussa, Harry I., Jr. [1 ]
McGrory, Kathleen R. [1 ]
McGrory, Kevin J. [1 ]
机构
[1] Univ Texas Houston, Hlth Sci Ctr, Sch Dent, Dept Orthodont, Houston, TX 77030 USA
[2] Univ Alabama Birmingham, Sch Dent, Dept Orthodont, Birmingham, AL USA
关键词
DIGITAL MODELS; PLASTER MODELS; SPACE ANALYSIS; ACCURACY; RELIABILITY; INDEX; VALIDITY; TOOTH;
D O I
10.1016/j.ajodo.2011.12.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The purpose of this research was to determine the accuracy of digital models generated by cone-beam computed tomography and compare it with that of OrthoCAD models (Cadent, Carlstadt, NJ) for orthodontic diagnosis and treatment planning by using surface area analysis. Materials: Two sets of maxillary and mandibular digital models of 30 subjects were obtained. The models were made from impressions scanned with OrthoCAD and by conversion of related cone-beam computed tomography files. Each patient's matched pairs of maxillary and mandibular models were superimposed by using a software program and a best-fit algorithm; surface-to-surface analysis was then performed. The average linear differences between the 2 files at all points on the surfaces were measured, and tolerance levels of 0.25, 0.5, 0.75, 1.0, 1.25, and 1.5 mm were set to determine the surface correlation amounts between the 2 files. Additionally, 6 linear measurements from predetermined landmarks were also measured and analyzed. Results: The average maxillary model linear difference was 0.28 to 0.60 mm, whereas the average mandibular model linear difference ranged between 0.34 and 0.61 mm. Greater than a 90% surface correlation was obtained on average at 1.00 mm in the maxillary models and at 1.25 mm in the mandibular models. The mean differences obtained from the linear measurements of the maxillary and mandibular models were 0.071 and 0.018 mm, respectively. Conclusions: Surface-to-surface analysis of OrthoCAD and digital models generated by cone-beam computed tomography pointed to a fair overlap between the protocols. The accuracy of digital models generated by cone-beam computed tomography is adequate for initial diagnosis and treatment planning in orthodontics. (Am J Orthod Dentofacial Orthop 2012;141:686-93)
引用
收藏
页码:686 / 693
页数:8
相关论文
共 50 条
  • [1] Imaging Analysis of Onodi Cells on Cone-Beam Computed Tomography
    Ali, Ibrahim K.
    Sansare, Kaustubh
    Karjodkar, Freny
    Saalim, Mohd
    INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2020, 24 (03) : 319 - 322
  • [2] Kilovoltage cone-beam computed tomography imaging dose estimation and optimization: Need of daily cone-beam computed tomography
    Trivedi, Gaurav
    Dixit, Chandra K.
    Oinam, Arun S.
    Kapoor, Rakesh
    Bahl, Amit
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (03) : 470 - 474
  • [3] Cone-Beam Computed Tomography for Temporomandibular Joint Imaging
    Dhabale, Gunjan S.
    Bhowate, Rahul R.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (11)
  • [4] Concrescence: Cone-Beam Computed Tomography Imaging Perspective
    Syed, Ali Zakir
    Alluri, LeelaSubhashini Choudary
    Mallela, Dhiraj
    Frazee, Troy
    CASE REPORTS IN DENTISTRY, 2016, 2016
  • [5] Measurement of skin dose from cone-beam computed tomography imaging
    Sercan Akyalcin
    Jeryl D English
    Kenneth M Abramovitch
    Xiujiang J Rong
    Head & Face Medicine, 9
  • [6] Measurement of skin dose from cone-beam computed tomography imaging
    Akyalcin, Sercan
    English, Jeryl D.
    Abramovitch, Kenneth M.
    Rong, Xiujiang J.
    HEAD & FACE MEDICINE, 2013, 9
  • [7] History of imaging in orthodontics from Broadbent to cone-beam computed tomography
    Hans, Mark G.
    Palomo, J. Martin
    Valiathan, Manish
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2015, 148 (06) : 914 - 921
  • [8] The validity, reliability, and time requirement of study model analysis using cone-beam computed tomography-generated virtual study models
    Luu, N. S.
    Mandich, M-A.
    Flores-Mir, C.
    El-Bialy, T.
    Heo, G.
    Carey, J. P.
    Major, P. W.
    ORTHODONTICS & CRANIOFACIAL RESEARCH, 2014, 17 (01) : 14 - 26
  • [9] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Faccioli, Niccolo
    Foti, Giovanni
    Barillari, Marco
    Atzei, Andrea
    Mucelli, Roberto Pozzi
    SKELETAL RADIOLOGY, 2010, 39 (11) : 1087 - 1095
  • [10] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Niccolò Faccioli
    Giovanni Foti
    Marco Barillari
    Andrea Atzei
    Roberto Pozzi Mucelli
    Skeletal Radiology, 2010, 39 : 1087 - 1095