Rapid phenotype hemoglobin screening by high-resolution mass spectrometry on intact proteins

被引:8
|
作者
Helmich, Floris [1 ,3 ]
van Dongen, Joost L. J. [1 ]
Kuijper, Philip H. M. [3 ]
Scharnhorst, Volkher [2 ]
Brunsveld, Luc [1 ]
Broeren, Maarten A. C. [3 ]
机构
[1] Eindhoven Univ Technol, Biol Chem Lab, Dept Biomed Engn, Inst Complex Mol Syst,Expert Ctr Clin Chem Eindho, NL-5600 MB Eindhoven, Netherlands
[2] Catharina Hosp, Expert Ctr Clin Chem Eindhoven, Clin Lab, Eindhoven, Netherlands
[3] Expert Ctr Clin Chem Eindhoven, Maxima Medisch Ctr, Lab Clin Chem & Hematol, Veldhoven, Netherlands
关键词
Hemoglobin; Globulin; Hemoglobinopathy; Siclde cell; Thalassemia; Newborn screening; Mass spectrometry; Q-ToF; Macromolecular; SICKLE-CELL-DISEASE; VARIANTS; BLOOD; IDENTIFICATION; DISORDERS; DIAGNOSIS;
D O I
10.1016/j.cca.2016.07.006
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: Given the excellent performance of modern mass spectrometers, their clinical application for the analysis of macromolecules is a growing field of interest. This principle is explored by hemoglobin analysis, which is a representative example by its molecular weight and clinical relevance in e.g. screening programs for thalassemia and hemoglobin variants. Considering its abundance and cellular containment, pre-analysis is significantly reduced allowing for essential rapid acquisitions. Methods: By parallel analysis of routine diagnostics for hemoglobin variants and thalassemia, we acquired samples of adults who were consented for hemoglobinopathy screening in our clinical laboratory. The pre-analytical process comprised of red cell lysis only; without further digestion and purification steps, the samples were directly injected in an electrospray ionization quadrupole time-of-flight setup and the intact proteins were analyzed by flow injection analysis. After optimization of process parameters, the deconvoluted mass spectra revealed the presence of alpha- and beta-globulins. The reference ranges for the average mass of both globulins and their intensity ratio (alpha/beta-ratio) were deduced from a disease-free subgroup and patients with a hemoglobinopathy were compared. Results: The alpha/beta-ratio is a poor marker for thalassemia patients, yet deviant alpha/beta-ratios are found for patients with a hemoglobin variant. Mass deviations down to 1 Da can be resolved; even if the patient suffers from a heterozygotic disorder, the average mass is found outside the established reference interval. Conclusions: Although subjects with mild thalassemia were not detected, all patients with a hemoglobin variant were resolved by top-down mass spectrometry using the average globulin mass and the alpha/beta-ratio as screening parameters. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:220 / 226
页数:7
相关论文
共 50 条
  • [21] Screening the life cycle of Schistosoma mansoni using high-resolution mass spectrometry
    Ferreira, Monica Siqueira
    de Oliveira, Diogo Noin
    de Oliveira, Rosimeire Nunes
    Allegretti, Silmara Marques
    Catharino, Rodrigo Ramos
    [J]. ANALYTICA CHIMICA ACTA, 2014, 845 : 62 - 69
  • [22] Screening and Confirmation of Opioids, Amphetamines and Benzodiazepines in Wastewater by High-Resolution Mass Spectrometry
    Yuan S.
    Yu Z.-G.
    Wang H.-F.
    Xiang P.
    Shi Y.
    Yang H.
    Liu M.-X.
    Luo R.-X.
    Shen B.-H.
    [J]. Journal of Chinese Mass Spectrometry Society, 2021, 42 (06) : 1080 - 1090
  • [23] Automated de novo sequencing of proteins by tandem high-resolution mass spectrometry
    Horn, DM
    Zubarev, RA
    McLafferty, FW
    [J]. PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (19) : 10313 - 10317
  • [24] Mass microscopy: high-resolution imaging mass spectrometry
    Setou, Mitsutoshi
    Kurabe, Nobuya
    [J]. JOURNAL OF ELECTRON MICROSCOPY, 2011, 60 (01): : 47 - 56
  • [25] Rapid quantitative screening of cyanobacteria for production of anatoxins using direct analysis in real time high-resolution mass spectrometry
    Beach, Daniel G.
    Rafuse, Cheryl
    Melanson, Jeremy E.
    McCarron, Pearse
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2021, 35 (01)
  • [26] Rapid screening of new organic sulfates and alkaloids in single plant cells using nanospray high-resolution mass spectrometry
    Chang, Qing
    Peng, Yue'e
    Shi, Bin
    Hu, Shenghong
    Shuai, Qin
    [J]. ANALYTICAL METHODS, 2019, 11 (42) : 5359 - 5365
  • [27] Application of quadrupole-Orbitrap high-resolution mass spectrometry in rapid screening and identification of synthetic dyes in herbal medicines
    Guo, Changchuan
    Li, Ke
    Xing, Sheng
    Sun, Hua
    Shi, Feng
    Zhang, Guifang
    Sun, Haiyan
    [J]. EUROPEAN JOURNAL OF MASS SPECTROMETRY, 2019, 25 (05) : 419 - 427
  • [28] Surface swabbing technique for the rapid screening for pesticides using ambient pressure desorption ionization with high-resolution mass spectrometry
    Edison, Sara. E.
    Lin, Lora A.
    Gamble, Bryan M.
    Wong, Jon
    Zhang, Kai
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (01) : 127 - 139
  • [29] HIGH-RESOLUTION LASER MASS-SPECTROMETRY
    NEUSSER, HJ
    BOESL, U
    WEINKAUF, R
    SCHLAG, EW
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1984, 60 (SEP): : 147 - 156
  • [30] Highlight report: high-resolution mass spectrometry
    Blaszkewicz, Meinolf
    [J]. ARCHIVES OF TOXICOLOGY, 2016, 90 (12) : 3149 - 3150