Comparing the levels of ssHCG, progesterone and estradiol between ectopic pregnancy and normal intrauterine pregnancy

被引:0
|
作者
Gharabaghi, Parvin [1 ]
Abdollahifard, Seddighe [1 ]
Gharabaghi, Manizheh [2 ]
Nouri, Mohammad [3 ]
机构
[1] Tabriz Univ Med Sci, Alzahra Hosp, Dept Obstet & Gynecol, Tabriz, Iran
[2] Tabriz Univ Med Sci, Alzahra Hosp, Dept Pediat, Tabriz, Iran
[3] Tabriz Univ Med Sci, Alzahra Hosp, Dept Biochem, Tabriz, Iran
关键词
beta subunit of human chorionic gonadotropin (ssHCG); estradiol; progesterone; ectopic pregnancy; normal intrauterine pregnancy;
D O I
暂无
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Background: The value of serial measurement of serum ss subunit of human chorionic gonadotropin (ssHCG) and ultrasonography in the early diagnosis of ectopic pregnancy has well established. Objective: The objective of this study was to explore the diagnostic value of raising level of serum ssHCG, single measurement of progesterone (P) and estradiol (E-2) in early diagnosis of ectopic pregnancy. Materials and Methods: Serum levels of ssHCG and estradiol were measured by Radio Immuno Sorbent Assay (RIA) and progesterone level was measured by Enzyme Linked Immuno Sorbent Assay (ELISA) techniques in 43 symptomatic women with ectopic pregnancy and 42 women with normal intrauterine pregnancy in Alzahra Hospital, Tabriz, Iran. These values were compared by T-test. By determining cut-off levels of these parameters the efficiency and sensitivity of them in prediction of ectopic pregnancy was estimated. Results: The mean serum levels of ssHCG, estradiol and progesterone in patients with ectopic pregnancies (940 +/- 552 mlu/ml, 593 +/- 237 pg/ml, 5.83 +/- 3.41 ng/ml, respectively) were significantly lower than these levels in normal intrauterine pregnancies (4620 +/- 2030 mlu/ml, 1627 +/- 435 pg/ml, 24.8 +/- 6.08 ng/ml, respectively). The average rate of ssHCG rising was 8.2% for 24 hours in patients with ectopic pregnancy (EP) and 32.8% in normal intrauterine pregnancies (NIUP). Conclusions In this study single measurement of serum progesterone level has the greatest sensitivity (100%) and specificity (98%) in the diagnosis of ectopic pregnancy.
引用
收藏
页码:187 / 190
页数:4
相关论文
共 50 条
  • [21] Heterotopic pregnancy: Tubal ectopic pregnancy with a viable IVF intrauterine pregnancy
    Melendez, J.
    Paraskevopolou, S. M.
    Foo, X.
    Yoong, W.
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2010, 30 (07) : 742 - 743
  • [22] PLASMA-LEVELS OF PROGESTERONE, ESTRADIOL AND ESTRIOL IN HUMAN PREGNANCY
    TUNGSUBUTRA, V
    FRANCE, JT
    NEW ZEALAND MEDICAL JOURNAL, 1977, 86 (597) : 351 - 351
  • [23] ECTOPIC PREGNANCY AND INTRAUTERINE CONTRACEPTIVE DEVICE
    PORGES, RF
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1974, 118 (08) : 1155 - 1155
  • [24] SIMULTANEOUS RUPTURED ECTOPIC AND INTRAUTERINE PREGNANCY
    KAZMANN, HA
    BARNETT, LA
    PARK, A
    SURGERY, 1953, 33 (03) : 391 - 393
  • [25] INTRAUTERINE-DEVICE AND ECTOPIC PREGNANCY
    BURKE, M
    BRITISH MEDICAL JOURNAL, 1977, 1 (6054): : 169 - 169
  • [26] COMBINED INTRAUTERINE AND TUBAL ECTOPIC PREGNANCY
    WONG, WSF
    MAO, K
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 1989, 29 (01): : 76 - 77
  • [27] COEXISTENT INTRAUTERINE AND ECTOPIC PREGNANCY - A REEVALUATION
    HANN, LE
    BACHMAN, DM
    MCARDLE, CR
    RADIOLOGY, 1984, 152 (01) : 151 - 154
  • [28] Intrauterine Fluid With Ectopic Pregnancy A Reappraisal
    Benson, Carol B.
    Doubilet, Peter M.
    Peters, Hope E.
    Frates, Mary C.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2013, 32 (03) : 389 - 393
  • [29] INTRAUTERINE-DEVICE AND ECTOPIC PREGNANCY
    ERKKOLA, R
    LIUKKO, P
    CONTRACEPTION, 1977, 16 (06) : 569 - 574
  • [30] THE INTRAUTERINE-DEVICE AND ECTOPIC PREGNANCY
    EDELMAN, DA
    PORTER, CW
    CONTRACEPTION, 1987, 36 (01) : 85 - 96