Correlation between frequency doubling technology perimetry and temporal frequency characteristics in early glaucoma

被引:4
|
作者
Yu, JJH
Kiyosawa, M
Nemoto, N
Momose, K
Mori, H
Mochizuki, M
机构
[1] Taipei Ho Ping Hosp, Dept Ophthalmol, Taipei, Taiwan
[2] Kanagawa Inst Technol, Dept Informat Network Engn, Atsugi, Kanagawa, Japan
关键词
frequency doubling technology; pseudorandom stimulation; temporal frequency characteristics; VEP;
D O I
10.1023/A:1026270726285
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To assess the effectiveness of the temporal frequency characteristics (TFC) as an indicator of visual damage in patients with early open-angle glaucoma, TFC obtained from VEPs elicited by a pseudorandom binary sequence (PRBS) stimulus was compared with the frequency doubling technology (FDT) thresholds. Cross power spectrum between the PRBS stimulus as the input and the PRBS-VEPs as the output was calculated, and was used as the TFC. The normalized amplitude of the TFC at 2-4, 6-8, 10-12, 14-16, 18-20, 22-24, 26-28, and 30-32 Hz was calculated, and a coefficient of correlation between these values and the FDT thresholds was determined. The coefficients of correlation between the FDT thresholds and the TFC at 18-20 Hz for the central, 10degrees, 20degrees, and 30degrees were r = 0.03,0.31,0.2 1, and 0.16, respectively in non-glaucomatous normal control eyes, and those for the same regions of eyes with early glaucoma were r = 0.66, 0.46, 0.38, and 0.35, respectively. The coefficients of correlation between the FDT thresholds and TFC at temporal frequencies were relatively high at 18-20 and 26-32 Hz. The time required to obtain the PRBS-VEP data was approximately the same as that for the FDT thresholds. The strong correlation between the two tests indicates that the FDT values and the high temporal frequency segments of the TFC may be useful as a preliminary indicator of visual damage in patients with early open-angle glaucoma. In addition, the strong correlation suggests that there was a preferential damage to the magnocellular system in glaucomatous eyes.
引用
收藏
页码:93 / 99
页数:7
相关论文
共 50 条
  • [1] Correlation between frequency doubling technology perimetry and temporal frequency characteristics in early glaucoma*
    Joseph Jy-Haw Yu
    Motohiro Kiyosawa
    Nobuyuki Nemoto
    Keiko Momose
    Hiroshi Mori
    Manabu Mochizuki
    [J]. Documenta Ophthalmologica, 2003, 107 : 93 - 99
  • [2] Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
    Seong Ah Kim
    Chan Kee Park
    Hae-Young Lopilly Park
    [J]. Scientific Reports, 12
  • [3] Comparison between frequency-doubling technology perimetry and standard automated perimetry in early glaucoma
    Kim, Seong Ah
    Park, Chan Kee
    Park, Hae-Young Lopilly
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)
  • [4] Relationship between indices of Humphrey perimetry and Frequency Doubling Technology perimetry in glaucoma
    Fukushima, A
    Shirakashi, M
    Yaoeda, K
    Funaki, S
    Funaki, H
    Ofuchi, N
    Abe, H
    [J]. JOURNAL OF GLAUCOMA, 2004, 13 (02) : 114 - 119
  • [5] Frequency doubling perimetry in glaucoma early diagnosis
    Brusini, P
    Busatto, P
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 : 23 - 24
  • [6] Frequency doubling perimetry in glaucoma early diagnosis
    De Gregorio, F
    Trani, M
    Sedran, L
    Virno, M
    Pannarale, MR
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1999, 40 (04) : S69 - S69
  • [7] Frequency doubling perimetry in glaucoma
    Thomas, R
    Bhat, S
    Muliyil, JP
    Parikh, R
    George, R
    [J]. JOURNAL OF GLAUCOMA, 2002, 11 (01) : 46 - 50
  • [8] The ability of frequency doubling technology perimetry in the diagnosis of glaucoma
    Zhao, X
    Xu, L
    Zhang, R
    Ma, Y
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U491 - U491
  • [9] Topographical correlation between frequency doubling perimetry findings and structural changes in glaucoma
    Anton, A
    Sobas, EM
    Sebastián, MA
    de Quiros, PB
    Ioba, MA
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U494 - U494
  • [10] Ibopamine test and frequency doubling perimetry in early glaucoma diagnosis
    Virno, M
    Gregorio, FDE
    Saccucci, S
    Angelini, MJ
    Palmieri, M
    [J]. ACTA OPHTHALMOLOGICA SCANDINAVICA, 2002, 80 : 31 - 31