Reproducibility of measuring amniotic fluid index and single deepest vertical pool throughout gestation

被引:14
|
作者
Sande, J. A. [1 ,2 ,3 ]
Ioannou, C. [2 ,3 ]
Sarris, I. [2 ,3 ]
Ohuma, E. O. [2 ,3 ,4 ]
Papageorghiou, A. T. [2 ,3 ]
机构
[1] Aga Khan Univ Hosp, Dept Radiol, Nairobi, Kenya
[2] Univ Oxford, Green Templeton Coll, Oxford Maternal & Perinatal Hlth Inst OMPHI, Oxford, England
[3] Univ Oxford, John Radcliffe Hosp, Nuffield Dept Obstet & Gynecol, Oxford OX3 9DU, England
[4] Univ Oxford, Botnar Res Ctr, Ctr Stat Med, Oxford, England
基金
比尔及梅琳达.盖茨基金会;
关键词
RANDOMIZED CLINICAL-TRIAL; INTERGROWTH-21(ST) PROJECT; INTRAOBSERVER VARIATION; 4-QUADRANT ASSESSMENT; BIOPHYSICAL PROFILE; POCKET TECHNIQUE; VOLUME; INTEROBSERVER; OLIGOHYDRAMNIOS; PREGNANCIES;
D O I
10.1002/pd.4504
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
ObjectiveThe aim of this study is to assess the intraobserver and interobserver reproducibility of measurement of amniotic fluid index (AFI) and single deepest vertical pool (SDVP), also known as the maximal vertical pocket. MethodsA total of 175 fetuses were evaluated. For each fetus, two observers acquired duplicate sets of AFI and SDVP. Measurement differences were expressed as actual and percentage values. For all comparisons, Bland-Altman plots were used to compare differences, and limits of agreement were calculated. ResultsIntraobserver and interobserver agreement remained fairly constant with gestation, both for AFI and SDVP. The intraobserver limits of agreement for AFI were -5.2 to 5cm or -39% to 37%; whereas for SDVP, these were -2.6 to 2.4cm or -52% to 48%. The interobserver limits of agreement for AFI measurement were -7.3 to 7.1cm or -54% to 53% and for SDVP measurement were -2.5 to 2.5cm or -51% to 52%. Intraobserver coefficient of variation for SDVP was 14% and for AFI was 19%; the interobserver coefficient was 19% for both AFI and SDVP. ConclusionLimits of agreement for both methods are wide. The choice of method should be dictated by clinical considerations other than method reproducibility. (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:434 / 439
页数:6
相关论文
共 50 条
  • [41] Single Deepest Vertical Pocket or Amniotic Fluid Index as Evaluation Test for Predicting Adverse Pregnancy Outcome (SAFE Trial): A Multicenter, Open-Label, Randomized Controlled Trial EDITORIAL COMMENT
    Kehl, S.
    Schelkle, A.
    Thomas, A.
    Puhl, A.
    Meqdad, K.
    Tuschy, B.
    Berlit, S.
    Weiss, C.
    Bayer, C.
    Heimrich, J.
    Dammer, U.
    Raabe, E.
    Winkler, M.
    Faschingbauer, F.
    Beckmann, M. W.
    Suetterlin, M.
    OBSTETRICAL & GYNECOLOGICAL SURVEY, 2016, 71 (10) : 578 - 580
  • [42] INTRAOBSERVER RELIABILITY OF AMNIOTIC-FLUID VOLUME ESTIMATION BY 2 TECHNIQUES - AMNIOTIC-FLUID INDEX VS MAXIMUM VERTICAL POCKET
    WILLIAMS, K
    WITTMANN, B
    DANSEREAU, J
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1993, 3 (05) : 346 - 349
  • [43] Effect of Maternal Body Mass Index and Amniotic Fluid Index on the Accuracy of Sonographic Estimation of Fetal Weight in Late Gestation
    Blitz, Matthew J.
    Rochelson, Burton
    Stork, Leah B.
    Augustine, Stephanie
    Greenberg, Meir
    Sison, Cristina P.
    Vohra, Nidhi
    AMERICAN JOURNAL OF PERINATOLOGY, 2018, 35 (13) : 1235 - 1240
  • [44] The maximal vertical pocket and amniotic fluid index in predicting fetal distress in prolonged pregnancy
    Dasari, P.
    Niveditta, G.
    Raghavan, S.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2007, 96 (02) : 89 - 93
  • [45] Amniotic fluid index in normal pregnancy: An assessment of gestation specific reference values among Indian women
    Khadilkar, SS
    Desai, SS
    Tayade, SM
    Purandare, CN
    JOURNAL OF OBSTETRICS AND GYNAECOLOGY RESEARCH, 2003, 29 (03) : 136 - 141
  • [46] Amniotic fluid index and labor length of pregnancies induced beyond 41 weeks of gestation with unfavorable cervix
    Rizzo, N
    Farina, A
    Santarsiero, G
    Di Luzio, L
    Vitarelli, M
    Bovicelli, A
    Carinci, P
    Bovicelli, L
    GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 2000, 49 (04) : 244 - 248
  • [47] STUDIES ON HUMAN SEXUAL DEVELOPMENT .6. CONCENTRATIONS OF UNCONJUGATED DEHYDROEPIANDROSTERONE, ESTRADIOL, AND ESTRIOL IN AMNIOTIC-FLUID THROUGHOUT GESTATION
    WARNE, GL
    REYES, FI
    FAIMAN, C
    WINTER, JSD
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 1978, 47 (06): : 1363 - 1367
  • [48] Chinese Population Reference Curves for Ultrasound-Measured Amniotic Fluid Deepest Vertical Pocket in Dichorionic Twin Pregnancies, and Their Associations With Pregnancy Outcomes
    Lyu, Zhengxin
    Wu, Tianchen
    Lu, Shan
    Yuan, Pengbo
    Zhao, Yangyu
    Wei, Yuan
    MATERNAL-FETAL MEDICINE, 2024, 6 (01) : 29 - 36
  • [49] A randomised comparison between amniotic fluid index and maximum pool depth in the monitoring of post-term pregnancy
    Alfirevic, Z
    Luckas, M
    Walkinshaw, SA
    McFarlane, M
    Curran, R
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1997, 104 (02): : 207 - 211
  • [50] Chinese Population Reference Curves for Ultrasound-Measured Amniotic Fluid Deepest Vertical Pocket in Dichorionic Twin Pregnancies, and Their Associations With Pregnancy Outcomes
    Lyu Zhengxin
    Wu Tianchen
    Lu Shan
    Yuan Pengbo
    Zhao Yangyu
    Wei Yuan
    母胎医学杂志(英文), 2024, 06 (01)