Reproducibility of measuring amniotic fluid index and single deepest vertical pool throughout gestation

被引:14
|
作者
Sande, J. A. [1 ,2 ,3 ]
Ioannou, C. [2 ,3 ]
Sarris, I. [2 ,3 ]
Ohuma, E. O. [2 ,3 ,4 ]
Papageorghiou, A. T. [2 ,3 ]
机构
[1] Aga Khan Univ Hosp, Dept Radiol, Nairobi, Kenya
[2] Univ Oxford, Green Templeton Coll, Oxford Maternal & Perinatal Hlth Inst OMPHI, Oxford, England
[3] Univ Oxford, John Radcliffe Hosp, Nuffield Dept Obstet & Gynecol, Oxford OX3 9DU, England
[4] Univ Oxford, Botnar Res Ctr, Ctr Stat Med, Oxford, England
基金
比尔及梅琳达.盖茨基金会;
关键词
RANDOMIZED CLINICAL-TRIAL; INTERGROWTH-21(ST) PROJECT; INTRAOBSERVER VARIATION; 4-QUADRANT ASSESSMENT; BIOPHYSICAL PROFILE; POCKET TECHNIQUE; VOLUME; INTEROBSERVER; OLIGOHYDRAMNIOS; PREGNANCIES;
D O I
10.1002/pd.4504
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
ObjectiveThe aim of this study is to assess the intraobserver and interobserver reproducibility of measurement of amniotic fluid index (AFI) and single deepest vertical pool (SDVP), also known as the maximal vertical pocket. MethodsA total of 175 fetuses were evaluated. For each fetus, two observers acquired duplicate sets of AFI and SDVP. Measurement differences were expressed as actual and percentage values. For all comparisons, Bland-Altman plots were used to compare differences, and limits of agreement were calculated. ResultsIntraobserver and interobserver agreement remained fairly constant with gestation, both for AFI and SDVP. The intraobserver limits of agreement for AFI were -5.2 to 5cm or -39% to 37%; whereas for SDVP, these were -2.6 to 2.4cm or -52% to 48%. The interobserver limits of agreement for AFI measurement were -7.3 to 7.1cm or -54% to 53% and for SDVP measurement were -2.5 to 2.5cm or -51% to 52%. Intraobserver coefficient of variation for SDVP was 14% and for AFI was 19%; the interobserver coefficient was 19% for both AFI and SDVP. ConclusionLimits of agreement for both methods are wide. The choice of method should be dictated by clinical considerations other than method reproducibility. (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:434 / 439
页数:6
相关论文
共 50 条
  • [1] Comparison of Amniotic Fluid Index and Single Deepest Vertical Pocket
    Shivananda, Roopa Padavagodu
    Anbu, Rekha
    Rao, Shubha
    Hegde, Nivedita
    Mundkur, Anjali Suneel
    Hebbar, Shripad
    CURRENT WOMENS HEALTH REVIEWS, 2022, 18 (02) : 93 - 99
  • [2] A Survey of Perinatologists Amniotic Fluid Index or Deepest Vertical Pocket?
    Quinones, Joanne N.
    Reynolds, R. Melody
    Rochon, Meredith L.
    Brown, Katie Karabasz
    Smulian, John C.
    OBSTETRICS AND GYNECOLOGY, 2014, 123 : 194S - 196S
  • [3] ULTRASOUND ASSESSMENT OF AMNIOTIC-FLUID VOLUME - A COMPARISON OF THE SINGLE DEEPEST POOL AND AMNIOTIC-FLUID INDEX TO PREDICT PERINATAL MORBIDITY
    AJAYI, RA
    SOOTHILL, PW
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1991, 1 (06) : 401 - 404
  • [4] Value of the amniotic fluid index compared with the single deepest pocket
    Ross, MG
    OBSTETRICS AND GYNECOLOGY, 2005, 105 (02): : 439 - 440
  • [5] Amniotic fluid index and single deepest pocket: Weak indicators of abnormal amniotic volumes
    Magann, EF
    Chauhan, SP
    Barrilleaux, PS
    Whitworh, NS
    Martin, JN
    OBSTETRICS AND GYNECOLOGY, 2000, 96 (05): : 737 - 740
  • [6] The influence of fetal position on amniotic fluid index and single deepest pocket
    Fok, W. Y.
    Chan, L. Y.
    Lau, T. K.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2006, 28 (02) : 162 - 165
  • [7] The evidence for abandoning the amniotic fluid index in favor of the single deepest pocket
    Magann, Everett F.
    Chauhan, Suneet P.
    Doherty, Dorota A.
    Magann, Marcia I.
    Morrison, John C.
    AMERICAN JOURNAL OF PERINATOLOGY, 2007, 24 (09) : 549 - 555
  • [8] Value of the amniotic fluid index compared with the single deepest pocket - In reply
    Magann, EF
    Chauhan, SP
    Morrison, JC
    OBSTETRICS AND GYNECOLOGY, 2005, 105 (02): : 440 - 441
  • [9] Amniotic fluid index versus single deepest vertical pocket: A meta-analysis of randomized controlled trials
    Nabhan, Ashraf F.
    Abdelmoula, Yasser A.
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2009, 104 (03) : 184 - 188
  • [10] Amniotic fluid index versus single deepest vertical pocket as a screening test for preventing adverse pregnancy outcome
    Nabhan, Ashraf F.
    Abdelmoula, Yaser A.
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2008, (03):