Right Ventricle to Pulmonary Artery Conduit With Tricuspid Expanded Polytetrafluoroethylene Valves

被引:3
|
作者
Kobayashi, Kei [1 ]
Shinkawa, Takeshi [1 ]
Yamagishi, Masaaki [1 ]
Saito, Satoshi [1 ]
Nakayama, Yuki [1 ]
Hoki, Ryogo [1 ]
Yoshida, Hisashi [1 ]
Niinami, Hiroshi [1 ]
机构
[1] Tokyo Womens Med Univ, Heart Inst Japan, Dept Cardiovasc Surg, Tokyo, Japan
来源
ANNALS OF THORACIC SURGERY | 2021年 / 112卷 / 03期
关键词
OUTFLOW TRACT RECONSTRUCTION; MONOCUSP VALVE;
D O I
10.1016/j.athoracsur.2020.06.119
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Excellent outcomes of right ventricle to pulmonary artery conduits with expanded polytetra-fluoroethylene (ePTFE) valves have been reported. The purpose of this study was to evaluate the outcomes of the different material conduits with tricuspid ePTFE valves. Methods. Forty-one consecutive patients who received right ventricle to pulmonary artery conduit with tricuspid ePTFE valves for biventricular repair between April 2004 and December 2016 were studied. The conduits made of autologous pericardial roll or xenograft roll were used in 22 patients (group P) and the conduits made of ePTFE tube were used in 19 patients (group G). The conduit reoperation and the conduit dysfunction were analyzed. Results. During the median follow-up of 5.8 years, no death related to the conduit was observed. There were four reoperations (three in group P and one in group G). Freedom from conduit reoperation at 5 years was 100% in both groups (P = .30). Freedom from more than moderate conduit stenosis at 5 years after operation was not significantly different between groups (46.9% in group P vs 76.3% in group G, P = .23) even though the group G conduits were significantly smaller and freedom from more than moderate conduit regurgitation at 5 years was significantly better in group G (63.3% in group P vs 94.1% in group G, P = .04). Conclusions. The conduit with ePTFE valves in the ePTFE tubes had better conduit function compared with the conduit with autologous pericardial or xenograft roll, especially in terms of conduit regurgitation. (C) 2021 by The Society of Thoracic Surgeons
引用
收藏
页码:831 / 837
页数:7
相关论文
共 50 条
  • [21] Homograft valved right ventricle to pulmonary artery conduit as a modification of the norwood procedure
    Reinhartz, O
    Reddy, VM
    MacDonald, MJ
    Lamberti, JJ
    Petrossian, E
    Perry, SB
    Suleman, S
    Hanley, FL
    CIRCULATION, 2005, 112 (17) : U577 - U577
  • [22] Right ventricle-pulmonary artery conduit with intake port in the Norwood procedure
    Aeba, Ryo
    Yozu, Ryohei
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2012, 144 (05): : 1260 - 1262
  • [23] Impact of right ventricle to pulmonary artery conduit on outcome of the modified norwood procedure
    Azakie, A
    Martinez, D
    Sapru, A
    Fineman, J
    Teitel, D
    Karl, TR
    ANNALS OF THORACIC SURGERY, 2004, 77 (05): : 1727 - 1733
  • [24] Porcine stentless valve/bovine pericardial conduit for right ventricle to pulmonary artery
    Vrandecic, MOP
    Fantini, FA
    Gontijo, BF
    Martins, CN
    Vrandecic, E
    ANNALS OF THORACIC SURGERY, 1998, 66 (06): : S179 - S182
  • [25] Relief of Right Ventricle to Pulmonary Artery Conduit Compression by Chest Wall Resection
    Kogon, Brian E.
    Jain, Ashish
    McGuinness, Jonathan
    Lutz, Jerre
    Jokhadar, Maan
    McConnell, Michael
    Book, Wendy
    CONGENITAL HEART DISEASE, 2011, 6 (06) : 634 - 637
  • [26] CONSTRUCTION OF AN AORTIC HOMOGRAFT CONDUIT FOR RIGHT VENTRICLE TO PULMONARY-ARTERY CONTINUITY
    HOOTS, AV
    WATSON, DC
    ANNALS OF THORACIC SURGERY, 1989, 48 (05): : 731 - 732
  • [27] Hemodynamic profile after the Norwood procedure with right ventricle to pulmonary artery conduit
    Maher, KO
    Pizarro, C
    Gidding, SS
    Januszewska, K
    Malec, E
    Norwood, WI
    Murphy, JD
    CIRCULATION, 2003, 108 (07) : 782 - 784
  • [28] HEMODYNAMICS AFTER SURGICAL REPAIR WITH RIGHT VENTRICLE TO PULMONARY-ARTERY CONDUIT
    ROSENTHAL, A
    ROCCHINI, AP
    KEANE, JF
    CASTANEDA, AR
    NADAS, AS
    CIRCULATION, 1975, 52 (04) : 102 - 102
  • [29] Right ventricle-to-pulmonary artery conduit in Norwood operation: a work in progress
    Briceno-Medina, Mario
    Kumar, T. K. Susheel
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2021, 59 (02) : 511 - 511
  • [30] Is stent placement effective for palliation of right ventricle to pulmonary artery conduit stenosis?
    Aggarwal, Sanjeev
    Garekar, Swati
    Forbes, Thomas J.
    Turner, Daniel R.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (04) : 480 - 484