Gabapentin quantification in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study

被引:52
|
作者
Ifa, DR
Falci, M
Moraes, ME
Bezerra, FAF
Moraes, MO
de Nucci, G
机构
[1] Univ Sao Paulo, Cartesius Analyt Unit, Dept Pharmacol, ICB, BR-05508900 Sao Paulo, Brazil
[2] Fed Univ Ceara, Dept Pharmacol, BR-60431970 Ceara, Brazil
来源
JOURNAL OF MASS SPECTROMETRY | 2001年 / 36卷 / 02期
关键词
gabapentin; human plasma; chromatography; mass spectrometry;
D O I
10.1002/jms.120
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid, sensitive and specific analytical method was developed and validated to quantify gabapentin in human plasma using acetaminophen as an internal standard. The method employs a single plasma protein precipitation. The analytes are chromatographed on a C-4 reversed-phase chromatographic column and analyzed by mass spectrometry in the multiple reaction monitoring (MRM) mode. The method has a chromatographic run time of 4 min and a linear calibration curve over the range 50-10000 ng ml(-1) (I. > 0.999). The between-run precision, based on the relative standard deviation for replicate quality controls, was less than or equal to 14.8 % (200 ng ml(-1)), 6.0% (1000 ng ml(-l)) and 4.4% (5000 ng ml-l). The between-run accuracy was +/-2.6, 4.4 and 0.5% for the above-mentioned concentrations, respectively. This method was employed in a bioequivalence study of two gabentin capsule formulations (Progresse from Biosintetica, Brazil, as a test formulation, and Neurotin from Parke-Davis, as a reference formulation) in 24 healthy volunteers of both sexes who received a single 300 mg dose of each formulation. The study was conducted using an open, randomized, two-period crossover design with a 7-day washout interval. The 90% confidence interval (CI) of the individual ratio geometric mean for Progresse/Neurotin was 87.9-115.6% for AUC((0-36) (h)) and 88.6-111.7% for C-max. Since both 90% CI for AUC((0-36 h)) and C-max were included in the 80-125% interval proposed by the US Food and Drug Administration, Progresse was considered bioequivalent to Neurotin according to both the rate and extent of absorption. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:188 / 194
页数:7
相关论文
共 50 条
  • [31] Quantification of dapaconazole in human plasma using high-performance liquid chromatography coupled to tandem mass spectrometry: Application to a phase I study
    de Moraes, Fernanda C.
    Bittencourta, Samara F.
    Perissutti, Elisa
    Frencentese, Francesco
    Arruda, Andre M. M.
    Chen, Lu Shi
    Babadopulos, Tainah
    De Nucci, Gilberto
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 958 : 102 - 107
  • [32] High-throughput quantification of perindopril in human plasma by liquid chromatography/tandem mass spectrometry: application to a bioequivalence study
    Nirogi, RVS
    Kandikere, VN
    Shukla, M
    Mudigonda, K
    Maurya, S
    Komarneni, P
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (12) : 1864 - 1870
  • [33] Determination of bromazepam in human plasma by high-performance liquid chromatography with electrospray ionization tandem mass spectrometric detection: application to a bioequivalence study
    Andraus, MH
    Wong, A
    Silva, OA
    Wada, CY
    Toffleto, O
    Azevedo, CP
    Salvadori, MC
    [J]. JOURNAL OF MASS SPECTROMETRY, 2004, 39 (11): : 1348 - 1355
  • [34] Determination of levocetirizine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study
    Morita, M. R.
    Berton, D.
    Boldin, R.
    Barros, F. A. P.
    Meurer, E. C.
    Amarante, A. R.
    Campos, D. R.
    Calafatti, S. A.
    Pereira, R.
    Abib, E., Jr.
    Pedrazolli, J., Jr.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 132 - 139
  • [35] Determination of memantine in human plasma by liquid chromatography-electrospray tandem mass spectrometry: Application to a bioequivalence study
    Almeida, A. A.
    Campos, D. R.
    Bernasconi, G.
    Calafatti, S.
    Barros, F. A. P.
    Eberlin, M. N.
    Meurer, E. C.
    Paris, E. G.
    Pedrazzoli, J.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 848 (02): : 311 - 316
  • [36] Determination of clindamycin in human plasma by liquid chromatography electrospray tandem mass spectrometry: application to the bioequivalence study of clindamycin
    Yu, LL
    Chao, CK
    Liao, WJ
    Twu, TY
    Liu, CM
    Yang, TH
    Lin, ET
    [J]. JOURNAL OF CHROMATOGRAPHY B, 1999, 724 (02): : 287 - 294
  • [37] Determination of 21-hydroxydeflazacort in human plasma by high-performance liquid chromatography/atmospheric pressure chemical ionization tandem mass spectrometry. Application to bioequivalence study
    Ifa, DR
    Moraes, ME
    Moraes, MO
    Santagada, V
    Caliendo, G
    de Nucci, G
    [J]. JOURNAL OF MASS SPECTROMETRY, 2000, 35 (03): : 440 - 445
  • [38] Quantification of an alkylphosphocholine antitumor agent in plasma by pneumatically assisted electrospray: Tandem mass spectrometry coupled with high-performance liquid chromatography
    Knebel, NG
    Locher, M
    [J]. DRUGS OF TODAY, 1998, 34 : 141 - 152
  • [39] Quantification of Paroxetine in Human Plasma by Liquid Chromatography Coupled with Electrospray Ionization Tandem Mass Spectrometry
    Shah, Hiten J.
    Kundlik, Mohan L.
    Kakad, Abhijit
    Patel, Nitesh K.
    Pandya, Ankit
    Khatri, Vanita
    Prajapati, Shivkumat
    Subbaiah, Gunta
    Patel, Chhagan N.
    [J]. JOURNAL OF AOAC INTERNATIONAL, 2010, 93 (01) : 141 - 149
  • [40] Atenolol quantification in human plasma by high-performance liquid chromatography: Application to bioequivalence study
    de Abreu, LRP
    de Castro, SAC
    Pedrazzoli, J
    [J]. AAPS PHARMSCI, 2003, 5 (02):