Three-dimensional (3D) Printed Vestibular Schwannoma for Facial Nerve Tractography Validation

被引:1
|
作者
Epprecht, Lorenz [1 ,2 ]
Qureshi, Ahad [1 ,2 ]
Kozin, Elliott D. [1 ,2 ]
McInturff, Stephen [1 ,2 ]
Remenschneider, Aaron [1 ,3 ]
Huber, Alexander M. [4 ,5 ]
Brown, Merrit Christian [1 ,2 ]
Barker, Frederick G., II [6 ]
Reinshagen, Katherine L. [7 ,8 ]
Lee, Daniel J. [1 ,2 ]
机构
[1] Massachusetts Eye & Ear, Eaton Peabody Labs, Boston, MA USA
[2] Harvard Med Sch, Dept Otol & Laryngol, Boston, MA 02115 USA
[3] Univ Massachusetts, Sch Med, Dept Otolaryngol, Amherst, MA 01003 USA
[4] Univ Hosp Zurich, Dept Otorhinolaryngol & Head & Neck Surg, Zurich, Switzerland
[5] Univ Zurich, Zurich, Switzerland
[6] Massachusetts Gen Hosp, Dept Neurosurg, Boston, MA 02114 USA
[7] Massachusetts Eye & Ear Infirm, Dept Radiol, Boston, MA 02114 USA
[8] Harvard Med Sch, Boston, MA 02115 USA
关键词
Diffusion tensor imaging; Image guidance; Preoperative planning; Tractography; Vestibular schwannoma; DIFFUSION TENSOR TRACTOGRAPHY; IMAGING TRACTOGRAPHY; CRANIAL NERVES;
D O I
10.1097/MAO.0000000000003058
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objectives: Predicting the course of cranial nerve (CN) VII in the cerebellopontine angle (CPA) on preoperative imaging for vestibular schwannoma (VS) may help guide surgical resection and reduce complications. Diffusion MRI based tractography has been used to identify cranial nerve trajectory, but intraoperative validation of this novel approach is challenging. Currently, validation is based on operative report descriptions of the course of cranial nerves, but yields a simplified picture of the three-dimensional (3D) course of CN VII. In this study, we investigate the accuracy of tractography with detailed patient-specific 3D-printed VS tumors. Design: Retrospective case review. Setting: Tertiary referral center. Participants: Twenty adult VS surgical candidates. Main Outcome Measures: We compared tractography with intraoperative 3D course of CN VII. The surgeons were blinded to tractography and drew the intraoperative course of the CN VII on a patient specific 3D-printed tumor model for detailed comparison with tractography. Results: Of 20 patients, one was excluded due to subtotal removal and inability to assess CN VII course. In the remaining 19 patients, 84% (16/19) tractography was successful. In 94% of tumors with tractography (15/16), the intraoperative description of CN VII course matched the tractography finding. The maximum distance, however, between tractography and intraoperative course of CN VII was 3.7 mm +/- 4.2 mm. Conclusion: This study presents a novel approach to CN VII tractography validation in VS. Although descriptions of CN VII intraoperatively match tractography, caution is warranted as quantitative measures suggest a clinically significant distance between tractography and CN VII course.
引用
收藏
页码:E598 / E604
页数:7
相关论文
共 50 条
  • [21] Three-dimensional (3D) printed scaffold and material selection for bone repair
    Zhang, Lei
    Yang, Guojing
    Johnson, Blake N.
    Jia, Xiaofeng
    ACTA BIOMATERIALIA, 2019, 84 : 16 - 33
  • [22] A three-dimensional (3D) printed paediatric trachea for airway management training
    Carter, Jane C.
    Broadbent, James
    Murphy, Ella C.
    Guy, Bernard
    Baguley, Katherine E.
    Young, Jeremy
    ANAESTHESIA AND INTENSIVE CARE, 2020, 48 (03) : 243 - 245
  • [23] Integration of digital maxillary dental casts with 3D facial images in orthodontic patients: A three-dimensional validation study
    Xiao, Zhuoxing
    Liu, Zijin
    Gu, Yan
    ANGLE ORTHODONTIST, 2020, 90 (03) : 397 - 404
  • [24] Three-dimensional modeling of facial nerve VII
    Peterson, Dani
    FASEB JOURNAL, 2014, 28 (01):
  • [25] Antenna with three dimensional 3D printed substrates
    Patel, S. S.
    Zuazola, I. J. Garcia
    Whittow, W. G.
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2016, 58 (04) : 741 - 744
  • [26] Spatial relationship between vestibular schwannoma and facial nerve on three-dimensional T2-weighted fast spin-echo MR images
    Sartoretti-Schefer, S
    Kollias, S
    Valavanis, A
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2000, 21 (05) : 810 - 816
  • [27] Erratum to: Development and analysis of three-dimensional (3D) printed biomimetic ceramic ossicles
    Jung-Seob Lee
    Young-Joon Seol
    Min Sung
    Wonkyu Moon
    Sung Won Kim
    Jeong-Hoon Oh
    Dong-Woo Cho
    International Journal of Precision Engineering and Manufacturing, 2017, 18 : 141 - 141
  • [28] 3D printed three-dimensional metallic microlattices with controlled and tunable mechanical properties
    Saleh, Mohammad Sadeq
    Hu, Chunshan
    Brenneman, Jacob
    Al Mutairi, Al Muntasar
    Panat, Rahul
    ADDITIVE MANUFACTURING, 2021, 39
  • [29] The accuracy and reliability of 3D printed aortic templates: a comprehensive three-dimensional analysis
    Rynio, Pawel
    Wojtun, Maciej
    Wojcik, Lukasz
    Kawa, Milosz
    Falkowski, Aleksander
    Gutowski, Piotr
    Kazimierczak, Arkadiusz
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (02) : 1385 - 1396
  • [30] Harnessing Path Optimization to Enhance the Strength of Three-Dimensional (3D) Printed Concrete
    Jiang, Xiongzhi
    Li, Yujia
    Yang, Zhe
    Li, Yangbo
    Xiong, Bobo
    BUILDINGS, 2024, 14 (02)