The Limits of Reproducibility in Numerical Simulation

被引:15
|
作者
Diethelm, Kai
机构
关键词
numerical analysis; Parallel algorithms; scientific computing;
D O I
10.1109/MCSE.2011.21
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Modern computational simulation's increasing and mainly speed-oriented use of HPC systems often conflicts with the goal of making research reproducible. Indeed, the simulations that result from HPC use often behave reproducibly in only a limited way As a discussion of this phenomenon's technical background describes, the problems entailed will be very difficult to overcome.
引用
收藏
页码:64 / 71
页数:8
相关论文
共 50 条
  • [21] Limits of reproducibility and hydrodynamic noise in atmospheric regional modelling
    Geyer, Beate
    Ludwig, Thomas
    von Storch, Hans
    COMMUNICATIONS EARTH & ENVIRONMENT, 2021, 2 (01):
  • [22] Limits to robustness and reproducibility in the demarcation of operational taxonomic units
    Schmidt, Thomas S. B.
    Rodrigues, Joao F. Matias
    von Mering, Christian
    ENVIRONMENTAL MICROBIOLOGY, 2015, 17 (05) : 1689 - 1706
  • [23] FACTORS AFFECTING REPRODUCIBILITY OF NUMERICAL CLASSIFICATIONS
    LOCKHART, WR
    JOURNAL OF BACTERIOLOGY, 1967, 94 (04) : 826 - &
  • [24] Estimation of numerical reproducibility on CPU and GPU
    Jezequel, Fabienne
    Lamotte, Jean-Luc
    Said, Issam
    PROCEEDINGS OF THE 2015 FEDERATED CONFERENCE ON COMPUTER SCIENCE AND INFORMATION SYSTEMS, 2015, 5 : 675 - 680
  • [25] LIMITS OF BIOLOGICAL SIMULATION
    CONRAD, M
    JOURNAL OF THEORETICAL BIOLOGY, 1974, 45 (02) : 585 - 590
  • [26] Revisiting reproducibility in transportation simulation studies
    Kevin Riehl
    Anastasios Kouvelas
    Michail A. Makridis
    European Transport Research Review, 17 (1)
  • [27] Validity limits for the van Genuchten-Mualem model and implications for parameter estimation and numerical simulation
    Ippisch, O.
    Vogel, H. -J.
    Bastian, P.
    ADVANCES IN WATER RESOURCES, 2006, 29 (12) : 1780 - 1789
  • [28] LIMITS OF REPRODUCIBILITY OF BLOOD-FLOW MEASUREMENTS BY DOPPLER ECHOCARDIOGRAPHY
    MEIJBOOM, EJ
    RIJSTERBORGH, H
    BOT, H
    DEBOO, JAJ
    ROELANDT, JRTC
    BOM, N
    PEDIATRIC CARDIOLOGY, 1987, 8 (03) : 224 - 224
  • [29] LIMITS OF REPRODUCIBILITY OF BLOOD-FLOW MEASUREMENTS BY DOPPLER ECHOCARDIOGRAPHY
    MEIJBOOM, EJ
    RIJSTERBORGH, H
    BOT, H
    DEBOO, JAJ
    ROELANDT, JRTC
    BOM, N
    AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (01): : 133 - 137
  • [30] A Discussion on the Limits to Coating Reproducibility Based on Heat Transfer Instabilities
    Robert B. Heimann
    Journal of Thermal Spray Technology, 2019, 28 : 327 - 332