MASS TRANSFER COEFFICIENTS IN PULSED PERFORATED-PLATE EXTRACTION COLUMNS

被引:87
|
作者
Torab-Mostaedi, M. [1 ]
Safdari, J. [1 ]
Ghaemi, A. [1 ]
机构
[1] Nucl Sci & Technol Res Inst, Nucl Fuel Cycle Res Sch, Tehran, Iran
关键词
Pulsed perforated-plate column; Mass transfer coefficient; Axial diffusion model; Effective diffusivity; Enhancement factor; LIQUID-LIQUID-EXTRACTION; EFFECTIVE DIFFUSIVITY; PREDICTION; DROPS; DESIGN;
D O I
10.1590/S0104-66322010000200003
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
This study examined the mass transfer performance in a pulsed perforated-plate extraction column with diameter of 50 mm using two different liquid systems. Mass transfer coefficients have been interpreted in terms of the axial diffusion model. The effects of pulsation intensity and dispersed and continuous phase velocities on the mass transfer performance have been investigated. Three different operating regimes, namely mixer-settler, transition, and emulsion regimes, were observed when the input energy was changed. Effective diffusivity is substituted for molecular diffusivity in the Gibber equation for prediction of dispersed phase overall mass transfer coefficients. A single correlation is derived in terms of Reynolds number, Eotvos number and dispersed phase holdup for prediction of the enhancement factor in all operating regimes. The prediction of overall mass transfer coefficients from the presented model is in good agreement with experimental results.
引用
收藏
页码:243 / 251
页数:9
相关论文
共 50 条
  • [41] MASS TRANSFER PERFORMANCE IN PULSED DISC AND DOUGHNUT EXTRACTION COLUMNS
    Torab-Mostaedi, M.
    Ghaemi, A.
    Asadollahzadeh, M.
    Pejmanzad, P.
    BRAZILIAN JOURNAL OF CHEMICAL ENGINEERING, 2011, 28 (03) : 447 - 456
  • [42] Mass transfer performance in Karr reciprocating plate extraction columns
    Stella, Angela
    Mensforth, Kathryn H.
    Bowser, Tim
    Stevens, Geoffrey W.
    Pratt, H. R. Clive
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2008, 47 (11) : 3996 - 4007
  • [43] Enhancement of single liquid drop mass transfer coefficients in a perforated plate column
    Hashem, MA
    El-Bassuoni, AA
    COMPUTATIONAL METHODS IN MULTIPHASE FLOW, 2001, 29 : 109 - 118
  • [44] INFLUENCE OF MASS-TRANSFER DIRECTION ON EFFICIENCY OF A PULSED PERFORATED PLATE COLUMN
    KHEMANGKORN, V
    MOLINIER, J
    ANGELINO, H
    CHEMICAL ENGINEERING SCIENCE, 1978, 33 (04) : 501 - 508
  • [45] Steady state modeling of perforated plate extraction columns
    Ettouney, R. S.
    El-Rifai, M. A.
    Ghallab, A. O.
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2007, 46 (08) : 713 - 720
  • [46] Composition dynamics in perforated plate liquid extraction columns
    Ettouney, R. S.
    El-Rifai, M. A.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2011, 89 (11A): : 2228 - 2235
  • [47] Flow dynamics in perforated plate liquid extraction columns
    Ettouney, R. S.
    El-Rifai, M. A.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2012, 90 (10): : 1417 - 1424
  • [48] AXIAL HOLDUP IN PULSED PERFORATED-PLATE COLUMN OF PULSER FEEDER TYPE .1. NOZZLE PLATE AND SIEVE PLATE
    IKEDA, H
    SUZUKI, A
    KIYOSE, R
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1987, 29 (01): : 72 - 80
  • [49] Population Balance Modeling of Pulsed (Packed and Sieve-Plate) Extraction Columns: Coupled Hydrodynamic and Mass Transfer
    Jaradat, Moutasem
    Attarakih, Menwer
    Bart, Hans-Joerg
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2011, 50 (24) : 14121 - 14135
  • [50] THE DYNAMICS OF PULSED PLATE EXTRACTION COLUMNS .2. DROPLET SIZE STUDIES IN THE ABSENCE OF MASS-TRANSFER
    BATEY, W
    LONIE, SJ
    THOMPSON, PJ
    THORNTON, JD
    SOLVENT EXTRACTION AND ION EXCHANGE, 1987, 5 (04) : 573 - 596