Receive coil arrays and parallel imaging for functional magnetic resonance imaging of the human brain

被引:0
|
作者
de Zwart, Jacco A. [1 ]
van Gelderen, Peter [1 ]
Duyn, Jeff H. [1 ]
机构
[1] NINDS, Adv MRI Sect, Lab Funct & Mol Imaging, NIH, Bldg 36,Rm 4D04, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The use of multiple small receive coils has several advantages over a single larger (e.g. birdcage) coil. With an array of small receive coils, image signal-to-noise ratio (SNR) can be optimized throughout the field-of-view and the image acquisition process can be accelerated by use of parallel imaging (PI) techniques. In an accelerated PI experiment, data are undersampled during acquisition. Subsequently, artifact-free images are reconstructed based on the independently acquired signals from the elements of the receive coil array. PI techniques have recently been applied to functional MRI (fMRI) experiments of the human brain in order to improve the performance of commonly used single-shot techniques like echo-planar imaging (EPI). Potential benefits of PI-fMRI include the reduction of geometrical distortions due to oftresonance signals, the reduction of signal-loss in areas with substantial signal inhomogeneity, increases of the spatial and temporal resolution of the fMRI experiment and reduction of gradient acoustic noise. Although the loss in SNR, inherent to PI, can severely compromise MRI image quality, the effect on fMRi quality, which is governed by the temporal stability of the signal, is often not as severe. On the other hand, PlIs potential in mitigating the often severe image artifacts present in singleshot FMRI render it an important tool, in particular with the recent surge in high field MRI applications.
引用
收藏
页码:6318 / +
页数:2
相关论文
共 50 条
  • [41] An optimized quadrature RF receive coil for very-low-field (50.4 mT) magnetic resonance brain imaging
    Shen, Sheng
    Kong, Xiaohan
    Meng, Fanqin
    Wu, Jiamin
    He, Yucheng
    Guo, Pan
    Xu, Zheng
    JOURNAL OF MAGNETIC RESONANCE, 2022, 342
  • [42] Functional magnetic resonance imaging and brain functional connectivity in migraine
    Antonio Russo
    Gioacchino Tedeschi
    Alessandro Tessitore
    The Journal of Headache and Pain, 2015, 16
  • [43] Functional magnetic resonance imaging and brain functional connectivity in migraine
    Russo, Antonio
    Tedeschi, Gioacchino
    Tessitore, Alessandro
    JOURNAL OF HEADACHE AND PAIN, 2015, 16 : 1
  • [44] Surface Coil for Magnetic Resonance Imaging
    Ricardo Ferro, Beatriz Taimy
    Ramirez Aguilera, Andres
    Alvarez Guerra, Eloy Daniel
    REVISTA CUBANA DE INGENIERIA, 2015, 6 (01): : 13 - 21
  • [45] Parallel magnetic resonance imaging
    Ulrich Katscher
    Peter Börnert
    Neurotherapeutics, 2007, 4 : 499 - 510
  • [46] Parallel magnetic resonance imaging
    Katscher, Ulrich
    Boernert, Peter
    NEUROTHERAPEUTICS, 2007, 4 (03) : 499 - 510
  • [47] Parallel magnetic resonance imaging
    Larkman, David J.
    Nunes, Rita G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (07): : R15 - R55
  • [48] PARALLEL MAGNETIC RESONANCE IMAGING WITH LOCALIZED ARRAYS AND SINC INTERPOLATION (PILARS)
    Feng, Shuo
    Ji, Jim
    2011 8TH IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, 2011, : 795 - 798
  • [49] Lateralisation of nociceptive processing in the human brain: a functional magnetic resonance imaging study
    Youell, PD
    Wise, RG
    Bentley, DE
    Dickinson, MR
    King, TA
    Tracey, I
    Jones, AKP
    NEUROIMAGE, 2004, 23 (03) : 1068 - 1077
  • [50] Functional magnetic resonance imaging studies of face representation in the normal human brain
    Vincent, D
    Roberts, M
    Burkhalter, W
    NEUROIMAGE, 2001, 13 (06) : S1276 - S1276