Review of high energy x-ray computed tomography for non-destructive dimensional metrology of large metallic advanced manufactured components

被引:21
|
作者
Sun, Wenjuan [1 ]
Symes, Daniel R. [2 ]
Brenner, Ceri M. [2 ]
Boehnel, Michael [3 ]
Brown, Stephen [1 ]
Mavrogordato, Mark N. [4 ]
Sinclair, Ian [4 ]
Salamon, Michael [3 ]
机构
[1] Natl Phys Lab, Hampton Rd, Teddington TW11 0LW, Middx, England
[2] STFC Rutherford Appleton Lab, Cent Laser Facil, Didcot OX11 0QX, Oxon, England
[3] Fraunhofer Inst Integrierte Schaltungen IIS, Lraunhofer Entwicklungszentrum Rontgentech EZRT, Flugplatzstr 75, D-90768 Furth, Germany
[4] Univ Southampton, Southampton SO17 1BJ, Hants, England
关键词
casting; high energy; x-ray computed tomography; non-destructive; dimensional metrology; additive manufacturing; MEASUREMENT UNCERTAINTY EVALUATION; SCATTER CORRECTION METHODS; NEUTRON TOMOGRAPHY; SPATIAL-RESOLUTION; GEOMETRIC CALIBRATION; POROSITY MEASUREMENTS; COMPTON-SCATTERING; GENERAL FRAMEWORK; CT; RADIATION;
D O I
10.1088/1361-6633/ac43f6
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Advanced manufacturing technologies, led by additive manufacturing, have undergone significant growth in recent years. These technologies enable engineers to design parts with reduced weight while maintaining structural and functional integrity. In particular, metal additive manufacturing parts are increasingly used in application areas such as aerospace, where a failure of a mission-critical part can have dire safety consequences. Therefore, the quality of these components is extremely important. A critical aspect of quality control is dimensional evaluation, where measurements provide quantitative results that are traceable to the standard unit of length, the metre. Dimensional measurements allow designers, manufacturers and users to check product conformity against engineering drawings and enable the same quality standard to be used across the supply chain nationally and internationally. However, there is a lack of development of measurement techniques that provide non-destructive dimensional measurements beyond common non-destructive evaluation focused on defect detection. X-ray computed tomography (XCT) technology has great potential to be used as a non-destructive dimensional evaluation technology. However, technology development is behind the demand and growth for advanced manufactured parts. Both the size and the value of advanced manufactured parts have grown significantly in recent years, leading to new requirements of dimensional measurement technologies. This paper is a cross-disciplinary review of state-of-the-art non-destructive dimensional measuring techniques relevant to advanced manufacturing of metallic parts at larger length scales, especially the use of high energy XCT with source energy of greater than 400 kV to address the need in measuring large advanced manufactured parts. Technologies considered as potential high energy x-ray generators include both conventional x-ray tubes, linear accelerators, and alternative technologies such as inverse Compton scattering sources, synchrotron sources and laser-driven plasma sources. Their technology advances and challenges are elaborated on. The paper also outlines the development of XCT for dimensional metrology and future needs.
引用
收藏
页数:39
相关论文
共 50 条
  • [1] X-ray Computed Tomography for Non-Destructive Failure Analysis in Microelectronics
    Pacheco, Mario
    Goyal, Deepak
    [J]. 2010 INTERNATIONAL RELIABILITY PHYSICS SYMPOSIUM, 2010, : 252 - 258
  • [2] Non-destructive characterization of additively manufactured components with x-ray computed tomography for part qualification: A study with laboratory and synchrotron x-rays *
    Cakmak, Ercan
    Bingham, Philip
    Cunningham, Ross W.
    Rollett, Anthony D.
    Xiao, Xianghui
    Dehoff, Ryan R.
    [J]. MATERIALS CHARACTERIZATION, 2021, 173
  • [3] High-resolution, Non-destructive X-ray Tomography
    Holler, Mirko
    Guizar-Sicairos, Manuel
    Tsai, Esther H. R.
    Odstrcil, Michal
    Dinapoli, Roberto
    Mueller, Elisabeth
    Diaz, Ana
    Bunk, Oliver
    Raab, Jorg
    Aeppli, Gabriel
    [J]. CHIMIA, 2018, 72 (05) : 339 - 339
  • [4] NEW POSSIBILITIES OF NON-DESTRUCTIVE EVALUATION BY X-RAY COMPUTED-TOMOGRAPHY
    REIMERS, P
    GOEBBELS, J
    [J]. MATERIALS EVALUATION, 1983, 41 (06) : 732 - 737
  • [5] X-ray computed tomography for non-destructive analysis of early Medieval swords
    Stelzner, Joerg
    Gauss, Florian
    Schuetz, Philipp
    [J]. STUDIES IN CONSERVATION, 2016, 61 (02) : 86 - 101
  • [6] Employing X-ray computed tomography for the non-destructive ice cores analysis
    Khairedinova, A. G.
    Kutuzov, S. S.
    Mikhalenko, V. N.
    Korost, D., V
    Khomyak, A. N.
    [J]. LED I SNEG-ICE AND SNOW, 2020, 60 (02): : 182 - 191
  • [7] Non-destructive characterization of additive manufacturing components with computed tomography and 3D X-ray microscopy
    Villarraga-Gómez, Herminso
    Frederick, Curtis
    Brackman, Paul
    Andreyev, Andriy
    Trenikhina, Yulia
    Johnson, Nathan
    Bale, Hrishikesh
    [J]. e-Journal of Nondestructive Testing, 2024, 29 (Special Issue):
  • [8] On the non-destructive measurement of local mass transfer using X-ray computed tomography
    Wang, D.
    Huang, Y.
    Ewing, D.
    Chow, T.
    Cotton, J.
    Noseworthy, M. D.
    Ching, C. Y.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 81 : 531 - 541
  • [9] X-RAY INDUCED ACOUSTIC COMPUTED TOMOGRAPHY FOR NON-DESTRUCTIVE TESTING OF AIRCRAFT STRUCTURE
    Tran, Tiffany
    Samant, Pratik
    Xiang, Liangzhong
    Liu, Yingtao
    [J]. PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 1, 2019,
  • [10] Inconsistency in 9 mm bullets measured with non-destructive X-ray computed tomography
    Kumar, Jagadeesha
    Landheer, Dirk
    Barnes-Warden, Jane
    Fenne, Paul
    Attridge, Alex
    Williams, Mark A.
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2012, 214 (1-3) : 48 - 58