Inconsistency in 9 mm bullets measured with non-destructive X-ray computed tomography

被引:9
|
作者
Kumar, Jagadeesha [1 ]
Landheer, Dirk [2 ]
Barnes-Warden, Jane [3 ]
Fenne, Paul [3 ]
Attridge, Alex [1 ]
Williams, Mark A. [1 ]
机构
[1] Univ Warwick, WMG, Coventry CV4 7AL, W Midlands, England
[2] Simpact Engn Ltd, Royal Leamington Spa CV31 1HP, Warwick, England
[3] Metropolitan Police Serv, London SE1 0EH, England
关键词
X-ray computed tomography; Bullet geometry; Jacket thickness; Armour standards; TERMINAL BALLISTICS; IDENTIFICATION; GEOMETRY; IMPACT;
D O I
10.1016/j.forsciint.2011.07.018
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Fundamental to any ballistic armour standard is the reference projectile that is to be defeated. Typically, for certification, consistency of bullets is assumed. Therefore, practical variations in bullet jacket dimensions can have far reaching consequences. Traditionally, internal dimensions could only be analysed by cutting bullets which rules out any subsequent ballistic assessment. Therefore, the use of a non-destructive X-ray computed tomography (CT) method is explored in this paper. A set of 10 bullets (9 mm DM11) was taken for analysing both intra and inter bullet jacket thickness variation. CT measurements of jacket thickness were validated with high resolution scanning electron microscope (SEM) images. An image based analysis methodology has been developed to extract the jacket thickness map and the centre of gravity. Thickness variations of the order of 200 mu m were found commonly across all the bullets along the length and an angular variation of up to 100 mu m was found in a few bullets. Jacket thickness and centre of gravity were also calculated for the same bullets after impact and the variations between the pre- and post-impacted bullets were compared, by establishing a common physical reference. The results show that the proposed CT scanning approach and subsequent image analysis method can bring out the statistical variations in bullet geometry pre- and post impact effectively. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:48 / 58
页数:11
相关论文
共 50 条
  • [1] Inconsistency in 9 mm bullets: Correlation of jacket thickness to post-impact geometry measured with non-destructive X-ray computed tomography
    Thornby, John
    Landheer, Dirk
    Williams, Tim
    Barnes-Warden, Jane
    Fenne, Paul
    Norman, Daniel
    Attridge, Alex
    Williams, Mark A.
    FORENSIC SCIENCE INTERNATIONAL, 2014, 234 : 111 - 119
  • [2] Inconsistency in 9 mm bullets: Correlation of jacket thickness to post-impact geometry measured with non-destructive X-ray computed tomography (vol 234, pg 111, 2014)
    Thornby, John
    Landheer, Dirk
    Williams, Tim
    Barnes-Warden, Jane
    Fenne, Paul
    Norman, Danielle
    Attridge, Alex
    Williams, Mark A.
    FORENSIC SCIENCE INTERNATIONAL, 2018, 282 : 92 - 92
  • [3] X-ray Computed Tomography for Non-Destructive Failure Analysis in Microelectronics
    Pacheco, Mario
    Goyal, Deepak
    2010 INTERNATIONAL RELIABILITY PHYSICS SYMPOSIUM, 2010, : 252 - 258
  • [4] NEW POSSIBILITIES OF NON-DESTRUCTIVE EVALUATION BY X-RAY COMPUTED-TOMOGRAPHY
    REIMERS, P
    GOEBBELS, J
    MATERIALS EVALUATION, 1983, 41 (06) : 732 - 737
  • [5] X-ray computed tomography for non-destructive analysis of early Medieval swords
    Stelzner, Joerg
    Gauss, Florian
    Schuetz, Philipp
    STUDIES IN CONSERVATION, 2016, 61 (02) : 86 - 101
  • [6] Employing X-ray computed tomography for the non-destructive ice cores analysis
    Khairedinova, A. G.
    Kutuzov, S. S.
    Mikhalenko, V. N.
    Korost, D., V
    Khomyak, A. N.
    LED I SNEG-ICE AND SNOW, 2020, 60 (02): : 182 - 191
  • [7] On the non-destructive measurement of local mass transfer using X-ray computed tomography
    Wang, D.
    Huang, Y.
    Ewing, D.
    Chow, T.
    Cotton, J.
    Noseworthy, M. D.
    Ching, C. Y.
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 81 : 531 - 541
  • [8] X-RAY INDUCED ACOUSTIC COMPUTED TOMOGRAPHY FOR NON-DESTRUCTIVE TESTING OF AIRCRAFT STRUCTURE
    Tran, Tiffany
    Samant, Pratik
    Xiang, Liangzhong
    Liu, Yingtao
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION, 2019, VOL 1, 2019,
  • [9] Non-destructive PCB Reverse Engineering Using X-ray Micro Computed Tomography
    Asadizanjani, Navid
    Shahbazmohamadi, Sina
    Tehranipoor, Mark
    Forte, Domenic
    ISTFA 2015: CONFERENCE PROCEEDINGS FROM THE 41ST INTERNATIONAL SYMPOSIUM FOR TESTING AND FAILURE ANALYSIS, 2015, : 164 - 172
  • [10] High-resolution, Non-destructive X-ray Tomography
    Holler, Mirko
    Guizar-Sicairos, Manuel
    Tsai, Esther H. R.
    Odstrcil, Michal
    Dinapoli, Roberto
    Mueller, Elisabeth
    Diaz, Ana
    Bunk, Oliver
    Raab, Jorg
    Aeppli, Gabriel
    CHIMIA, 2018, 72 (05) : 339 - 339