Programming implantable cardioverter-defibrillator in primary prevention: Guideline concordance and outcomes

被引:14
|
作者
Ananwattanasuk, Teetouch [1 ,2 ]
Tanawuttiwat, Tanyanan [3 ]
Chokesuwattanaskul, Ronpichai [1 ]
Lathkar-Pradhan, Sangeeta [1 ]
Barham, Waseem [4 ,5 ]
Oral, Hakan [1 ]
Thakur, Ranjan K. [4 ,5 ]
Jongnarangsin, Krit [1 ]
机构
[1] Univ Michigan Hlth Syst, Cardiac Electrophysiol, 1500 E Med Ctr Dr,SPC 5856, Ann Arbor, MI 48109 USA
[2] Navamindradhiraj Univ, Vajira Hosp, Cardiol Div, Dept Internal Med, Bangkok, Thailand
[3] Univ Mississippi, Med Ctr, Dept Med, Div Cardiol, Jackson, MS 39216 USA
[4] Michigan State Univ, Cardiac Electrophysiol, Lansing, MI USA
[5] Sparrow Thorac & Cardiovasc Inst, Lansing, MI USA
关键词
Implantable cardioverter-defibrillator; Implantable cardioverter; defibrillator programming guidelines; defibrillator shock; Implantable cardioverter-defibrillator therapy; Primary prevention; RAPID VENTRICULAR-TACHYCARDIA; INAPPROPRIATE THERAPY; HIGH-RISK; SHOCKS; MORTALITY; TRIAL; REDUCTION;
D O I
10.1016/j.hrthm.2020.02.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Inappropriate therapy is a common adverse effect in patients with an implantable cardioverter-defibrillator (ICD) that may be prevented by appropriate programming. OBJECTIVE The purpose of this study was to assess the outcomes of device programming based on a 2015 HRS/EHRA/APHRS/SOLAECE expert consensus statement and a 2019 focused update on optimal ICD programming and testing. METHODS Consecutive patients who underwent ICD insertion for primary prevention from 2014-2016 at 3 centers were included in the retrospective analysis. Patients were classified into 2 groups based on the tachycardia programming at the time of implant: guideline concordant group (GC) and non-guideline concordant group (NGC). Kaplan-Meier analysis and Cox proportional hazard models were used to estimate freedom from ICD therapy (antitachycardia pacing or shock), ICD shock, and death. RESULTS A total of 772 patients were included in the study (mean age 63.3 +/- 13.8 years). Of this total, 258 patients (33.4%) were in the GC group and 514 patients (66.6%) were in the NGC group. During mean follow-up of 2.02 +/- 0.91 years, guideline concordant programming was associated with a 53% reduction in ICD therapy (P < .01) and 50% reduction in ICD shock (P = .02). There were no significant differences in mortality (6% in GC group vs11% in NGC group; P = .22). CONCLUSION Only one-third of the studied population had an ICD device programmed in concordance with current guidelines. ICD programming based on the current guidelines was associated with a significantly lower rate of ICD therapy and shock without changes in mortality during intermediate-term follow-up. Published by Elsevier Inc. on behalf of Heart Rhythm Society.
引用
收藏
页码:1101 / 1106
页数:6
相关论文
共 50 条
  • [31] A prophylactic implantable cardioverter-defibrillator?
    Brugada, P
    Wellens, F
    Andries, E
    AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 : 128 - 133
  • [32] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    LATTUCA, J
    VELTRI, EP
    AMERICAN HEART JOURNAL, 1989, 118 (06) : 1359 - 1359
  • [33] Implantable cardioverter-defibrillator advances
    Lerman, RD
    Cannom, DS
    CURRENT OPINION IN CARDIOLOGY, 1996, 11 (01) : 16 - 22
  • [34] Outcomes in patients with cardiac amyloidosis and implantable cardioverter-defibrillator
    Kim, Eun-Jeong
    Holmes, Benjamin B.
    Huang, Shi
    Lugo, Ricardo
    Al Aboud, Asad
    Goodman, Stacey
    Hung, Rebecca R.
    Slosky, David
    Stevenson, William G.
    Michaud, Gregory F.
    John, Roy M.
    EUROPACE, 2020, 22 (08): : 1216 - 1223
  • [35] Indications for implantable Cardioverter-Defibrillator
    Tebbenjohanns, J
    Niehaus, M
    Korte, T
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2002, 127 (41) : 2120 - 2124
  • [36] AUTOMATIC IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR
    EPSTEIN, AE
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1991, 102 (01): : 160 - 161
  • [37] Implantable cardioverter-defibrillator utilization
    Camm, John
    EUROPACE, 2011, 13 (03): : 448 - 448
  • [38] Erosion of an Implantable Cardioverter-Defibrillator
    Elmouchi, Darryl
    Woelfel, Alan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (24) : E47 - E47
  • [39] The implantable cardioverter-defibrillator: An update
    Miller, Jared D.
    Yousuf, Omair
    Berger, Ronald D.
    TRENDS IN CARDIOVASCULAR MEDICINE, 2015, 25 (07) : 606 - 611
  • [40] Twiddling with an implantable cardioverter-defibrillator
    McCann, Conor J.
    Beelen, Roel
    Geelen, Peter