Perfusate Metabolomics Content and Expression of Tubular Transporters During Human Kidney Graft Preservation by Hypothermic Machine Perfusion

被引:6
|
作者
Faucher, Quentin [1 ]
Alarcan, Hugo [1 ,2 ]
Sauvage, Francois-Ludovic [1 ]
Forestier, Lionel [3 ]
Miquelestorena-Standley, Elodie [4 ,5 ]
Nadal-Desbarats, Lydie [6 ]
Arnion, Helene [1 ]
Venhard, Jean-Christophe [7 ]
Brichart, Nicolas [8 ]
Bruyere, Franck [9 ]
Marquet, Pierre [1 ,10 ]
Barin-Le Guellec, Chantal [1 ,2 ]
机构
[1] Univ Limoges, INSERM, P&T UMR1248, Limoges, France
[2] CHRU Tours, Serv Biochim & Biol Mol, 2 Blvd Tonnelle, F-37044 Tours, France
[3] Univ Limoges, US 042 INSERM UMS 2015 CNRS, BISCEm, Limoges, France
[4] CHRU Tours, Serv Anat & Cytol Pathol, Hop Trousseau, Tours, France
[5] Univ Tours, EA4245, Transplantat Immunobgie Inflammat, Tours, France
[6] Univ Tours, INSERM, iBrain, UMR 1253, Tours, France
[7] CHRU Tours, Coordinat Hosp Prelevements Organes & Tissus, Tours, France
[8] CHR Orleans, Serv Chirurg Urol, Orleans, France
[9] CHRU Tours, Serv Urol, Hop Bretonneau, Tours, France
[10] CHRU Limoges, Serv Pharmacol Toxicol & Pharmacovigilance, Limoges, France
关键词
DOWN-REGULATION; PCR DATA; TIME; IDENTIFY; CELLS;
D O I
10.1097/TP.0000000000004129
中图分类号
R392 [医学免疫学]; Q939.91 [免疫学];
学科分类号
100102 ;
摘要
Background. Ischemia-related injury during the preimplantation period impacts kidney graft outcome. Evaluating these lesions by a noninvasive approach before transplantation could help us to understand graft injury mechanisms and identify potential biomarkers predictive of graft outcomes. This study aims to determine the metabolomic content of graft perfusion fluids and its dependence on preservation time and to explore whether tubular transporters are possibly involved in metabolomics variations. Methods. Kidneys were stored on hypothermic perfusion machines. We evaluated the metabolomic profiles of perfusion fluids (n = 35) using liquid chromatography coupled with tandem mass spectrometry and studied the transcriptional expression of tubular transporters on preimplantation biopsies (n = 26), both collected at the end of graft perfusion. We used univariate and multivariate analyses to assess the impact of perfusion time on these parameters and their relationship with graft outcome. Results. Seventy-two metabolites were found in preservation fluids at the end of perfusion, of which 40% were already present in the native conservation solution. We observed an increase of 23 metabolites with a longer perfusion time and a decrease of 8. The predictive model for time-dependent variation of metabolomics content showed good performance (R-2 = 76%, Q(2) = 54%, accuracy = 41%, and permutation test significant). Perfusion time did not affect the mRNA expression of transporters. We found no correlation between metabolomics and transporters expression. Neither the metabolomics content nor transporter expression was predictive of graft outcome. Conclusions. Our results call for further studies, focusing on both intra- and extratissue metabolome, to investigate whether transporter alterations can explain the variations observed in the preimplantation period.
引用
收藏
页码:1831 / 1843
页数:13
相关论文
共 50 条
  • [31] Normothermic Ex-Vivo Kidney Perfusion Preservation Consistently Improves Extreme Marginal Graft Function Compared to Hypothermic Machine Perfusion.
    Urbanellis, P.
    Hamar, M.
    Linares, I.
    Kollmann, D.
    Ganesh, S.
    Oquendo, F.
    Sharma, M.
    John, R.
    Ghanekar, A.
    Mucsi, I.
    Bagli, D.
    Konvalinka, A.
    Robinson, L.
    Selzner, M.
    AMERICAN JOURNAL OF TRANSPLANTATION, 2019, 19 : 578 - 579
  • [32] Metabolomic Perfusate Analysis during Kidney Machine Perfusion: The Pig Provides an Appropriate Model for Human Studies
    Nath, Jay
    Guy, Alison
    Smith, Thomas B.
    Cobbold, Mark
    Inston, Nicholas G.
    Hodson, James
    Tennant, Daniel A.
    Ludwig, Christian
    Ready, Andrew R.
    PLOS ONE, 2014, 9 (12):
  • [33] TRIMETAZIDINE IS PROTECTIVE DURING KIDNEY PRESERVATION WITH MACHINE PERFUSION
    Codas, R.
    Kasil, A.
    Cau, J.
    Thierry, A.
    Hauet, T.
    Badet, L.
    TRANSPLANT INTERNATIONAL, 2016, 29 : 4 - 4
  • [34] TRIMETAZIDINE IS PROTECTIVE DURING KIDNEY PRESERVATION WITH MACHINE PERFUSION
    Codas, R.
    Kasil, A.
    Cau, J.
    Thierry, A.
    Hauet, T.
    Badet, L.
    TRANSPLANT INTERNATIONAL, 2016, 29 : 9 - 9
  • [35] Effect of continuous hypothermic machine perfusion transport system (Airdrive™) on canine kidney preservation
    Hu Xiaopeng
    Xue Wenrui
    Zhang Qiang
    Wang Wei
    Zhang Jiqing
    Zhang Xiaodong
    CHINESE MEDICAL JOURNAL, 2014, 127 (06) : 1105 - 1109
  • [36] Application of machine perfusion preservation as a viability test for marginal kidney graft
    Matsuno, Naoto
    Konno, Osamu
    Mejit, Abudushukur
    Jyojima, Yoshimaro
    Akashi, Isao
    Nakamura, Yuki
    Iwamoto, Hitoshi
    Hama, Koichiro
    Iwahori, Toru
    Ashizawa, Tatsuhito
    Nagao, Takeshi
    TRANSPLANTATION, 2006, 82 (11) : 1425 - 1428
  • [37] EFFECT OF CONTINUOS HYPOTHERMIC MACHINE PRESERVATION AND TIME OF PERFUSION IN THE OUTCOMES OF MARGINAL KIDNEY GRAFTS
    Ruiz Hernandez, Mercedes
    Gomez Dos Santos, Victoria
    Sanchez-Guerrero, Clara
    Elias-Rivino, Sandra
    Burgos Revilla, Javier
    TRANSPLANT INTERNATIONAL, 2019, 32 : 302 - 303
  • [38] Optimizing porcine donor kidney preservation with normothermic or hypothermic machine perfusion: A systematic review
    Bouari, Sarah
    Eryigit, Ozgur
    de Bruin, Ron W. F.
    IJzermans, Jan N. M.
    Minnee, Robert C.
    ARTIFICIAL ORGANS, 2021, 45 (11) : 1308 - 1316
  • [39] Quantified FMN perfusate levels correlate with early allograft dysfunction during hypothermic liver machine perfusion
    Kacar, S.
    Poumpouridou, E.
    Weijler, A.
    Horodynski, F.
    Dingfelder, J.
    Spasic, M.
    Tyercha, A.
    Krdzalic, O.
    Salat, A.
    Mathe, Z.
    Soliman, T.
    Kollman, D.
    Gyoeri, G.
    Berlakovich, G.
    TRANSPLANTATION, 2023, 107 (09) : 182 - 182
  • [40] Analysis of Perfusates During Hypothermic Machine Perfusion by NMR Spectroscopy: A Potential Tool for Predicting Kidney Graft Outcome
    Bon, Delphine
    Claire, Billault
    Thuillier, Raphael
    Hebrard, William
    Boildieu, Nadege
    Celhay, Olivier
    Irani, Jacques
    Seguin, Francois
    Hauet, Thierry
    TRANSPLANTATION, 2014, 97 (08) : 810 - 816