Measurement of spinal range of motion in healthy individuals using an electromagnetic tracking device

被引:26
|
作者
Hsu, Chien-Jen [1 ,2 ]
Chang, Yi-Wen [3 ]
Chou, Wen-Ying [4 ]
Chiou, Chou-Ping [2 ]
Chang, Wei-Ning [1 ]
Wong, Chi-Yin [1 ]
机构
[1] Kaohsiung Vet Gen Hosp, Dept Orthoped, Kaohsiung 813, Taiwan
[2] I Shou Univ, Dept Nursing, Kaohsiung Hsien, Taiwan
[3] Natl Taiwan Coll Phys Educ, Dept Exercise & Hlth Sci, Taichung, Taiwan
[4] Chang Gung Univ, Coll Med, Chang Gung Mem Hosp, Dept Anesthesiol,Kaohsiung Med Ctr, Kaohsiung, Taiwan
关键词
electromagnetic tracking device; range of motion; spine;
D O I
10.3171/SPI/2008/8/2/135
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. The authors measured the range of motion (ROM) of the spine in healthy individuals by using an electromagnetic tracking device to evaluate the functional performance of the spine. Methods. The authors used the Flock of Birds electromagnetic tracking device with 4 receiver units attached to C-7, T-12, S-1, and the midthigh region. Forward/backward bending, bilateral side bending, and axial rotation of the trunk were performed in 18 healthy individuals. Results. The average ROM was calculated after 3 consecutive measurements. The thoracic spine generated the greatest angle in axial rotation and smallest angle in backward bending. The lumbar spine generated the greatest angle in forward bending and smallest angle in axial rotation. The hip joints generated the greatest angle in forward bending and smallest angle in backward bending. Additionally, 40% of forward-bending motion occurred in the lumbar spine and 40% occurred in the hip joints. Approximately 60% of backward bending occurred in the lumbar spine; 60% of axial rotation occurred in the thoracic spine; and 45% of side bending occurred in the thoracic spine. Conclusions. The Flock of Birds electromagnetic tracking device cannot only measure the ROM of spine but also easily differentiate the 6-degree contributions by different segments.
引用
收藏
页码:135 / 142
页数:8
相关论文
共 50 条
  • [21] Functional passive range of motion of individuals with chronic cervical spinal cord injury
    Frye, Sara Kate
    Geigle, Paula Richley
    York, Henry S.
    Sweatman, W. Mark
    JOURNAL OF SPINAL CORD MEDICINE, 2020, 43 (02): : 257 - 263
  • [22] Measurement of the Range of Motion of Laparoscopic Instruments Based on an Optical Tracking System
    Lu, Kunyong
    Song, Chengli
    Yang, Lixiao
    Ai, Liaoyuan
    Shi, Qin
    JOURNAL OF MEDICAL DEVICES-TRANSACTIONS OF THE ASME, 2016, 10 (02):
  • [23] Quantifying diplopia using a cevical range of motion device
    Holmes, JM
    Leske, DA
    Kupersmith, MJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [24] Study on Motion Measurement of Human Upper Limb Based on Electromagnetic Tracking System
    Zhang, Jianguo
    Song, Haiyan
    Xue, Qiang
    IEEM: 2008 INTERNATIONAL CONFERENCE ON INDUSTRIAL ENGINEERING AND ENGINEERING MANAGEMENT, VOLS 1-3, 2008, : 768 - +
  • [25] Calibration of the "Flock of Birds" electromagnetic tracking device and its application in shoulder motion studies
    Meskers, CGM
    Fraterman, H
    van der Helm, FCT
    Vermeulen, HM
    Rozing, PM
    JOURNAL OF BIOMECHANICS, 1999, 32 (06) : 629 - 633
  • [26] Calibration of the 'Flock of Birds' electromagnetic tracking device and its application in shoulder motion studies
    Orthopaedic Laboratory, Dept. Orthoped. Surg., Leiden U., Leiden, Netherlands
    不详
    不详
    J. Biomech., 6 (629-633):
  • [27] People tracking using a robot in motion with laser range finder
    Lee, Jae Hoon
    Tsubouchi, Takashi
    Yamamoto, Kenjiro
    Egawa, Saku
    2006 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS, VOLS 1-12, 2006, : 2936 - +
  • [28] Development of an Objective Portable Measurement Device for Spinal Joint Accessory Motion Testing
    Wu, Hsiao-Kuan
    Lai, Hung-Jen
    Teng, Ting
    Yu, Chung-Huang
    SENSORS, 2020, 20 (01)
  • [29] Video based measurement of sagittal range of spinal motion in young and older adults
    Kuo, Yi-Liang
    Tully, Elizabeth A.
    Galea, Mary P.
    MANUAL THERAPY, 2009, 14 (06) : 618 - 622
  • [30] Evaluation of a long-range transmitter for use with a magnetic tracking device in motion analysis
    Day, JS
    Dumas, GA
    Murdoch, DJ
    JOURNAL OF BIOMECHANICS, 1998, 31 (10) : 957 - 961