Juvenile and adult congenital heart disease: Time-resolved 3D contrast-enhanced MR angiography

被引:31
|
作者
Fenchel, Michael
Saleh, Roya
Dinh, Howard
Lee, Margaret H.
Nael, Kambiz
Krishnam, Mayil
Ruehm, Stefan G.
Miller, Stephan
Child, John
Finn, J. Paul
机构
[1] Univ Tubingen, Dept Diagnost Radiol, D-72076 Tubingen, Germany
[2] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA USA
关键词
D O I
10.1148/radiol.2442061045
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the incremental diagnostic value of time-resolved three-dimensional (3D) magnetic resonance (MR) angiography over single-phase 3D MR angiography and cine MR imaging in juvenile and adult patients with congenital heart disease (CHD). Materials and Methods: The study was HIPAA compliant and was approved by the institutional review board. Written informed consent was obtained from each patient. Eighty-one consecutive patients (46 male and 35 female patients; mean age, 31.1 years +/- 13.5 [standard deviation]) with CHD were examined with a 1.5-T MR imaging unit. The imaging protocol comprised time- resolved MR angiography (repetition time msec/echo time msec, 2.01/ 0.81) after injection of 0.03 mmol gadodiamide per kilogram of body weight at 4 mL/ sec and single-phase high-spatial-resolution MR angiography (2.87/ 0.97) after injection of 0.15 mmol/ kg gadodiamide at 1.5 mL/ sec. After review of the time-resolved and conventional MR angiographic data sets, each of two independent observers listed the additional clinical information gained from timeresolved MR angiographic data. A Wilcoxon signed rank test was used to test for statistical differences between the image quality ratings of the two observers. Results: Time-resolved and single-phase high-spatial-resolution MR angiography yielded diagnostic image data in all patients. Observers 1 and 2 found functional information in time-resolved MR angiographic series in 52 and 51 patients, respectively, that was not seen at high-spatial-resolution MR angiography. Intra- and extracardiac shunts, respectively, were exclusively depicted by time-resolved MR angiography for observer 1 in 18 and two patients and for observer 2 in 15 and two patients. However, both observers reported higher confidence in the assessment of such smaller vascular structures as supraaortic vessels ( in 12 patients for observer 1 and 11 patients for observer 2) and major aortopulmonary collateral arteries (in eight patients for observer 1 and 10 patients for observer 2) at high-spatial-resolution MR angiography. No significant difference was evident in image quality scoring between the two observers (P =.32 for time- resolved and P =.47 for conventional MR angiography). Conclusion: Compared with conventional MR angiography, time-resolved MR angiography yields clinically relevant information in a substantial number of patients; hence, the two techniques should be regarded as complementary.
引用
收藏
页码:399 / 410
页数:12
相关论文
共 50 条
  • [31] Extrahepatic portosystemic shunt in congenital absence of the portal vein depicted by time-resolved contrast-enhanced MR angiography
    Hyun Woo Goo
    [J]. Pediatric Radiology, 2007, 37 : 706 - 709
  • [32] Postoperative assessment of extracranial-intracranial bypass by time-resolved 3D contrast-enhanced MR angiography using parallel imaging
    Tsuchiya, K
    Honya, K
    Fujikawa, A
    Tateishi, H
    Shiokawa, Y
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2005, 26 (09) : 2243 - 2247
  • [33] 3D Time-Resolved MR Angiography (MRA) of the Carotid Arteries with Time-Resolved Imaging with Stochastic Trajectories: Comparison with 3D Contrast-Enhanced Bolus-Chase MRA and 3D Time-Of-Flight MRA
    Lim, R. P.
    Shapiro, M.
    Wang, E. Y.
    Law, M.
    Babb, J. S.
    Rueff, L. E.
    Jacob, J. S.
    Kim, S.
    Carson, R. H.
    Mulholland, T. P.
    Laub, G.
    Hecht, E. M.
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (10) : 1847 - 1854
  • [34] The clinical utility of contrast-enhanced 3D MR angiography for cerebrovascular disease
    Okumura, A
    Araki, Y
    Nishimura, Y
    Iwama, T
    Kaku, Y
    Furuichi, M
    Sakai, N
    [J]. NEUROLOGICAL RESEARCH, 2001, 23 (07) : 767 - 771
  • [35] Time-resolved contrast-enhanced carotid MR angiography using sensitivity encoding (SENSE)
    Golay, X
    Brown, SJ
    Itoh, R
    Melhem, ER
    [J]. AMERICAN JOURNAL OF NEURORADIOLOGY, 2001, 22 (08) : 1615 - 1619
  • [36] Time-resolved three-dimensional contrast-enhanced MR angiography of the peripheral vessels
    Swan, JS
    Carroll, TJ
    Kennell, TW
    Heisey, DM
    Korosec, DM
    Frayne, R
    Mistretta, CA
    Grist, TM
    [J]. RADIOLOGY, 2002, 225 (01) : 43 - 52
  • [37] Time-resolved contrast-enhanced pulmonary MR angiography using sensitivity encoding (SENSE)
    Ohno, Y
    Kawamitsu, H
    Higashino, T
    Takenaka, D
    Watanabe, H
    van Cauteren, M
    Fujii, M
    Hatabu, H
    Sugimura, K
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) : 330 - 336
  • [38] Value of Sequential Subtraction of Time-Resolved MR Angiography in the Evaluation of Complex Adult Congenital Heart Disease
    Murphy, D.
    Murphy, B.
    McGee, A.
    Craddock, A.
    Lawler, L.
    Murray, J.
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [39] Whole-heart coronary magnetic resonance angiography - Contrast-enhanced high-resolution, time-resolved 3D imaging
    Warmuth, Carsten
    Schnorr, Joerg
    Kaufels, Nicola
    Wagner, Susanne
    Pilgrimm, Herbert
    Hamm, Bernd
    Taupitz, Matthias
    [J]. INVESTIGATIVE RADIOLOGY, 2007, 42 (08) : 550 - 557
  • [40] Low-Dose, Time-Resolved, Contrast-Enhanced 3D MR Angiography in the Assessment of the Abdominal Aorta and Its Major Branches at 3 Tesla
    Kramer, Ulrich
    Fenchel, Michael
    Laub, Gerhard
    Seeger, Achim
    Klumpp, Bernhard
    Bretschneider, Christiane
    Finn, J. Paul
    Claussen, Claus D.
    Miller, Stephan
    [J]. ACADEMIC RADIOLOGY, 2010, 17 (05) : 564 - 576