Research on Non-contact Angle Measurement Based on AMR Effect

被引:1
|
作者
Huang, Yinguo [1 ]
Zhuang, Shuya [1 ]
Wang, Zhiyi [1 ]
Zhang, Xiaomei [1 ]
Zhao, Meirong [1 ]
机构
[1] Tianjin Univ, State Key Lab Precis Measuring Technol & Instrume, Tianjin, Peoples R China
关键词
Angle measurement; Non-contact; AMR; Wheatstone bridge;
D O I
10.1007/978-981-10-6571-2_245
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A non-contact angle measuring method based on AMR effect is proposed in this paper. The method improves the measurement sensitivity and resolution with a Wheatstone bridge. In this paper, the function of the output voltage of the Wheatstone bridge is derived, which is on the angle between the direction of the external magnetic field and the bridge. Besides, the magnetic field distribution of a radially magnetized permanent magnet is analyzed. A device for measuring the angle in the range of +/- 10 degrees is designed, and the sensitivity of the device is about 15 mV/arcminute. The method introduced in this paper has advantages of simple structure, low cost, high sensitivity and free from space limitation.
引用
收藏
页码:2013 / 2019
页数:7
相关论文
共 50 条
  • [31] Research on a Novel Non-contact Metrology Technology of Stress Measurement Based on Deflection Method
    Lv, N.
    Hu, Y.
    Liu, D.
    Yang, Y.
    Wang, J.
    EXPERIMENTAL TECHNIQUES, 2021, 45 (06) : 809 - 825
  • [32] Research on non-contact torque measurement based on screw-type differential transformer
    Yu, CB
    Zhan, L
    Chen, XJ
    Zhai, F
    ICEMS 2005: Proceedings of the Eighth International Conference on Electrical Machines and Systems, Vols 1-3, 2005, : 2366 - 2368
  • [33] Non-contact and contact measurement Quick Vision
    不详
    AIRCRAFT ENGINEERING AND AEROSPACE TECHNOLOGY, 2001, 73 (04): : 423 - 423
  • [34] Non-contact and fast measurement of small roll angle using digital shearography
    Wu, Sijin
    Li, Xin
    Li, Weixian
    Si, Juanning
    Optics and Lasers in Engineering, 2022, 150
  • [35] Non-contact measurement of angle of view between the inspected surface and the thermal imager
    Muniz, Pablo Rodrigues
    Magalhaes, Robson da Silva
    Neves Cani, Shirley Peroni
    Donadel, Clainer Bravin
    INFRARED PHYSICS & TECHNOLOGY, 2015, 72 : 77 - 83
  • [36] Non-contact and fast measurement of small roll angle using digital shearography
    Wu, Sijin
    Li, Xin
    Li, Weixian
    Si, Juanning
    OPTICS AND LASERS IN ENGINEERING, 2022, 150
  • [37] Non-contact direct measurement of the magnetocaloric effect in thin samples
    Cugini, F.
    Porcari, G.
    Solzi, M.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2014, 85 (07):
  • [38] Novel non-contact torque measurement using the magnetomechanical effect
    Zhang, Xiaomei
    Zhao, Meirong
    Huang, Yinguo
    Zheng, Yelong
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2019, 47 (01) : 107 - 116
  • [39] NON-CONTACT METHOD FOR LENGTH MEASUREMENT USING DOPPLER EFFECT
    ZERVOS, P
    PTB-MITTEILUNGEN, 1978, 88 (03): : 193 - 197
  • [40] Research of an Absolute Encoding Method for Non-contact Linear Displacement Measurement
    Yan, Xuewen
    Sun, Qianlai
    2008 7TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-23, 2008, : 5858 - 5861