Porosity determination of ceramic materials by digital image analysis - A critical evaluation

被引:0
|
作者
Von Bradke, M
Gitzhofer, F
Henne, R
机构
[1] Univ Sherbrooke, Fac Engn, Dept Chem Engn, Sherbrooke, PQ PQJ1 K2R1, Canada
[2] Inst Tech Thermodynam, German Aerosp Ctr, Stuttgart, Germany
关键词
scanning electron microscopy; image analysis; porosity determination; metallographic preparation; grey level histogram;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Measuring the porosity of materials by digital image analysis of micrographs is a well-established and convenient method for the testing of metallic samples. However, when applied to ceramic materials, this method has been shown to be much less reliable and poorly reproducible. The purpose of this present work is to clarify the reason for this deficiency, involving many porosity measurements, performed on plasma-sprayed zirconia, under systematically varied microscopic imaging conditions, and the porosities being calculated using various evaluation methods. Comparison between of the results has shown that the present state of the image analysis method is not satisfactory for absolute porosity measurements on ceramic materials. It can be useful as a convenient tool for comparative measurements, however, if the imaging conditions maintained in the microscope and the evaluation method are held to be exactly identical.
引用
收藏
页码:132 / 135
页数:4
相关论文
共 50 条
  • [31] Silvering of High-Porosity Cellular Ceramic Materials
    N. A. Asnis
    O. A. Vasilenko
    M. D. Gasparyan
    I. O. Speshilov
    T. A. Vagramyan
    V. Kh. Aleshina
    Russian Journal of Applied Chemistry, 2020, 93 : 1518 - 1524
  • [32] Study on porosity of plasma-sprayed coatings by digital image analysis method
    Hao Du
    Soo Wohn Lee
    Jae Heyg Shin
    Journal of Thermal Spray Technology, 2005, 14 : 453 - 461
  • [33] Study on porosity of plasma-sprayed coatings by digital image analysis method
    Du, H
    Shin, JH
    Lee, SW
    JOURNAL OF THERMAL SPRAY TECHNOLOGY, 2005, 14 (04) : 453 - 461
  • [34] APPEARANCE EVALUATION BY DIGITAL IMAGE-ANALYSIS
    LUO, C
    BRESEE, RR
    TEXTILE CHEMIST AND COLORIST, 1990, 22 (02): : 17 - 19
  • [35] Analysis and evaluation of digital image compression techniques
    Gao, H
    Pan, J
    Qi, GS
    Zhao, LR
    OPTICAL RECORDING, STORAGE, AND RETRIEVAL SYSTEMS, 1996, 2890 : 124 - 128
  • [36] Determination of the properties of composite materials thanks to digital image correlation measurements
    Laurin, F.
    Charrier, J. -S.
    Leveque, D.
    Maire, J. -F.
    Mavel, A.
    Nunez, P.
    IUTAM SYMPOSIUM ON FULL-FIELD MEASUREMENTS AND IDENTIFICATION IN SOLID MECHANICS, 2011, 2012, 4 : 106 - 115
  • [37] Digital image analysis as a means of determination of urodynamic parameters
    Mathioulakis, DS
    Fidas, A
    Dik, P
    Tsangaris, S
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1996, 34 (02) : 181 - 184
  • [38] DETERMINATION OF MILLING YIELD BY DIGITAL IMAGE-ANALYSIS
    SYMONS, SJ
    FULCHER, RG
    CEREAL FOODS WORLD, 1988, 33 (08) : 668 - 669
  • [39] Digital image analysis as a means of determination of urodynamic parameters
    Mathioulakis, D.S.
    Fidas, A.
    Dik, P.
    Tsangaris, S.
    Medical and Biological Engineering and Computing, 1996, 34 (02): : 181 - 184
  • [40] Analysis of Asymmetrical Creep of a Ceramic at 1350°C by Digital Image Correlation
    Leplay, Paul (paul.leplay@saint-gobain.com), 1600, Blackwell Publishing Inc., Postfach 10 11 61, 69451 Weinheim, Boschstrabe 12, 69469 Weinheim, Deutschland, 69469, Germany