Correcting physiological noise in whole-head functional near-infrared spectroscopy

被引:25
|
作者
Zhang, Fan [1 ]
Cheong, Daniel [1 ]
Khan, Ali F. [1 ]
Chen, Yuxuan [2 ]
Ding, Lei [1 ,3 ]
Yuan, Han [1 ,3 ]
机构
[1] Univ Oklahoma, Stephenson Sch Biomed Engn, Norman, OK USA
[2] Univ Oklahoma, Sch Elect & Comp Engn, Norman, OK USA
[3] Univ Oklahoma, Inst Biomed Engn Sci & Technol, Norman, OK USA
基金
美国国家科学基金会;
关键词
Functional near-infrared spectroscopy; Physiological noise; Short-separation channels; Principal component analysis; General linear model; Contrast-to-noise ratio; HIGH-RESOLUTION EEG; HEMODYNAMIC-RESPONSE; GLOBAL INTERFERENCE; CONCURRENT FNIRS; BRAIN ACTIVATION; MOTOR CORTEX; FMRI SIGNAL; BLOOD-FLOW; CONNECTIVITY; BOLD;
D O I
10.1016/j.jneumeth.2021.109262
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Functional near-infrared spectroscopy (fNIRS) has been increasingly employed to monitor cerebral hemodynamics in normal and diseased conditions. However, fNIRS suffers from its susceptibility to superficial activity and systemic physiological noise. The objective of the study was to establish a noise reduction method for fNIRS in a whole-head montage. New Method: We have developed an automated denoising method for whole-head fNIRS. A high-density montage consisting of 109 long-separation channels and 8 short-separation channels was used for recording. Auxiliary sensors were also used to measure motion, respiration and pulse simultaneously. The method incorporates principal component analysis and general linear model to identify and remove a globally uniform superficial component. Our denoising method was evaluated in experimental data acquired from a group of healthy human subjects during a visually cued motor task and further compared with a minimal preprocessing method and three established denoising methods in the literature. Quantitative metrics including contrast-to-noise ratio, withinsubject standard deviation and adjusted coefficient of determination were evaluated. Results: After denoising, whole-head topography of fNIRS revealed focal activations concurrently in the primary motor and visual areas. Comparison with Existing Methods: Analysis showed that our method improves upon the four established preprocessing methods in the literature. Conclusions: An automatic, effective and robust preprocessing pipeline was established for removing physiological noise in whole-head fNIRS recordings. Our method can enable fNIRS as a reliable tool in monitoring largescale, network-level brain activities for clinical uses.
引用
收藏
页数:12
相关论文
共 50 条
  • [31] Superficial Fluctuations in Functional Near-Infrared Spectroscopy
    Zhang, Fan
    Cheong, Daniel
    Chen, Yuxuan
    Khan, Ali
    Ding, Lei
    Yuan, Han
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 4779 - 4782
  • [32] Functional imaging studies with near-infrared spectroscopy
    Kato, T
    INTERNATIONAL JOURNAL OF NEUROPSYCHOPHARMACOLOGY, 2004, 7 : S40 - S40
  • [33] Functional Near-Infrared Spectroscopy in HumanRobot Interaction
    Canning, Cody
    Scheutz, Matthias
    JOURNAL OF HUMAN-ROBOT INTERACTION, 2013, 2 (03): : 62 - U111
  • [34] Effects of whole-head 810 nm near-infrared therapy on cognitive and neuropsychiatric symptoms in Alzheimer's disease: A pilot study
    Guo, Rong
    Li, Deyu
    Li, Fang
    Ji, Linna
    Liu, Hongying
    Qiao, Huiting
    Lv, Zeping
    Tang, Yi
    Wang, Daifa
    JOURNAL OF ALZHEIMERS DISEASE, 2025, 104 (01) : 52 - 60
  • [35] Behaviour of near-infrared light in the adult human head: implications for clinical near-infrared spectroscopy
    Young, AER
    Germon, TJ
    Barnett, NJ
    Manara, AR
    Nelson, RJ
    BRITISH JOURNAL OF ANAESTHESIA, 2000, 84 (01) : 38 - 42
  • [36] NEAR-INFRARED OXIMETRY AND NEAR-INFRARED SPECTROSCOPY
    OWENREECE, H
    ELWELL, CE
    FALLON, P
    GOLDSTONE, J
    SMITH, M
    ANAESTHESIA, 1994, 49 (12) : 1102 - 1103
  • [37] Visualization of light propagation in visible Chinese human head for functional near-infrared spectroscopy
    Li, Ting
    Gong, Hui
    Luo, Qingming
    JOURNAL OF BIOMEDICAL OPTICS, 2011, 16 (04)
  • [38] Contribution of speckle noise in near-infrared spectroscopy measurements
    Ortega-Martinez, Antonio
    Zimmermann, Bernhard
    Cheng, Xiaojun
    Li, Xinge
    Yucel, Meryem Ayse
    Boas, David A.
    JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (10)
  • [39] Method for leveling the signal-to-noise ratio in multichannel functional near-infrared spectroscopy
    Yamada, Toru
    Umeyama, Shinji
    Kamoshida, Atsushi
    NEURAL IMAGING AND SENSING, 2017, 10051
  • [40] The utility of near-infrared spectroscopy in the regression of low-frequency physiological noise from functional magnetic resonance imaging data
    Cooper, R. J.
    Gagnon, Louis
    Goldenholz, Daniel M.
    Boas, David A.
    Greve, Douglas N.
    NEUROIMAGE, 2012, 59 (04) : 3128 - 3138