Durability of reinforced concrete beams strengthened by galvanized steel mesh-epoxy systems under harsh environmental conditions

被引:26
|
作者
Al Nuaimi, Nasser [1 ]
Sohail, Muazzam Ghous [1 ]
Hawileh, Rami A. [2 ]
Abdalla, Jamal A. [2 ]
Douier, Kais [2 ]
机构
[1] Qatar Univ, Ctr Adv Mat, POB 2713, Doha, Qatar
[2] Amer Univ Sharjah, Dept Civil Engn, POB 26666, Sharjah, U Arab Emirates
关键词
Galvanized steel mesh; Epoxy; Durability; Reinforced concrete; Infrastructure strengthening; Rehabilitation; RC BEAMS; POLYMER COMPOSITES; FLEXURAL BEHAVIOR; TEMPERATURE; PERFORMANCE; ISSUES;
D O I
10.1016/j.compstruct.2020.112547
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Strengthening and rehabilitation of reinforced concrete (RC) structural elements are being efficiently carried out by fiber-reinforced polymer (FRP) composite materials. However, their long-term durability is still causing concerns for the repairing industry. Recently, the use of steel wire mesh-epoxy systems for strengthening is gaining the attention of researchers and engineers and their long-term durability warrants investigation. This paper presents the results of an extensive experimental study carried out on 60 RC beams strengthened in flexure by medium and high cord density galvanized steel mesh (MSM, HSM). In order to evaluate the dura-bility of these strengthening systems, the RC beams were exposed to direct sunlight and immersed under saline water for 6,12, and 24 months. The beams were tested under four-point bending till failure after each exposure period. The MSM and HSM strengthened beams showed up to 51 and 62% higher load-carrying capacity than that of the control beams at 28 days, respectively, and up to 82% after two years of sun and saline water expo-sure. Furthermore, the exposed beams showed significant delay in crack initiation, no pronounced degradation in strength or stiffness, and no delamination of epoxy. On the contrary, there was significant improvement in the strength of the exposed beams, especially that of the MSM. Based on ACI 440.2R-17 Guidelines, environ-mental reduction factors were proposed for the exposed beams. This study showed that galvanized MSM and HSM laminates could be promising and durable alternative materials for rehabilitation, retrofitting, and strengthening of RC members under harsh climatic conditions of elevated temperature, high salinity, and high humidity.
引用
收藏
页数:17
相关论文
共 46 条
  • [41] Repair technique of pre-cracked reinforced concrete (RC) beams with transverse openings strengthened with steel plate under sustained load
    Osman, Bashir H.
    Wu, Erjun
    Bohai, Ji
    Abdallah, Mohammad
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2017, 31 (21) : 2360 - 2379
  • [42] Behavior of High-Strength Concrete Columns Reinforced with Galvanized Steel Equal-Angle Sections under Different Loading Conditions
    Hadi, Muhammad N. S.
    Ibrahim, Ayoob A.
    Sheikh, M. Neaz
    JOURNAL OF STRUCTURAL ENGINEERING, 2018, 144 (07)
  • [43] Experimental study of the mechanical properties of steel fiber stainless-steel reinforced concrete (SFSRC) beams under low velocity impact conditions
    Zhou, Xiwu
    Zhang, Wen
    Wang, Xiangyu
    ADVANCES IN MECHANICAL ENGINEERING, 2021, 13 (09)
  • [44] Experimental Study on the Impact Resistance of Steel Fiber Reinforced All-Lightweight Concrete Beams under Single and Hybrid Mixing Conditions
    Wang, Xiuli
    Wu, Qinyuan
    Chen, Wenlong
    BUILDINGS, 2023, 13 (05)
  • [45] Experimental Study on Shear Capacities of Reinforced Concrete Beams Strengthened by Direct-shearbolted Side-plates near Beam Ends Under Different Interfacial Conditions
    Quan X.
    Luo C.
    Liu J.
    Huang H.
    Tongji Daxue Xuebao/Journal of Tongji University, 2024, 52 (01): : 59 - 67
  • [46] Bond behavior and ultimate capacity of notched concrete beams with externally-bonded FRP and PBO-FRCM systems under different environmental conditions
    De Domenico, Dario
    Urso, Santi
    Borsellino, Chiara
    Spinella, Nino
    Recupero, Antonino
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 265