Dosimetric evaluation of the INTRABEAM system for breast intraoperative radiotherapy: A single-institution experience

被引:2
|
作者
Shaikh, Mubin Y. [1 ]
Nalichowski, Adrian [2 ]
Joiner, Michael C. [3 ]
Burmeister, Jay [2 ]
机构
[1] Rochester Reg, Dept Radiat Oncol, 1425 Portland Ave, Rochester, NY 14621 USA
[2] Wayne State Univ, Gershenson Radiat Oncol Ctr, Barbara Ann Karmanos Canc Inst, Dept Oncol,Sch Med, Detroit, MI USA
[3] Wayne State Univ, Gershenson Radiat Oncol Ctr, Dept Oncol, Detroit, MI 48201 USA
关键词
INTRABEAM; IORT; Dose-volume histograms; Breast IORT; Intraoperative dosimetry; RADIOSURGERY; MINIATURE; RADIATION; CANCER; TARGIT; TRIAL;
D O I
10.1016/j.meddos.2019.09.002
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Breast intraoperative radiotherapy (IORT) with the INTRABEAM system uses a 50 kV x-ray source to deliver a single fraction of radiation therapy to the lumpectomy cavity during breast-conserving surgery. We seek to perform a dosimetric analysis of the lumpectomy cavity for rigid spherical applicators. Water phantom measurements were acquired to validate the vendor-provided x-ray calibration. The planning target volume (PTV) was defined as a 10 mm expansion beyond the spherical applicator, a dose-volume histogram (DVH) was generated and dose-volume parameters [D-min, D-1mm, V-90, V-80, V-50, HI] were reported. Additionally, the therapeutic treatment depth using the 90 and 80% isodose level was computed [R-90, R-80]. When the percent depth dose (PDD) is normalized to the surface of the applicator, smaller applicators have a steeper PDD. For a prescription dose of 20 Gy to the surface of the applicator, the range of dose-volume parameters for the PTV was: 3.15 to 6.84 Gy for D-min, 16.2 to 17.6 Gy for D-1mm, 2.6 to 6.9% for V-90, 5.5 to 15.1% for V-80, and 21.1 to 55.6% for V-50. For applicators 15 to 50 mm in diameter, the reported values were: 6.35 to 2.9 for HI, 0.53 to 0.85 mm for R-90, and 1.18 to 1.85 mm for R-80. Smaller applicators have reduced PTV coverage but elevated HI because the attenuation of the beam proximal to the source is more pronounced. Additionally, the presence of the aluminum filter for small applicators (<= 30 mm) increases PTV coverage but reduces the dose rate on the applicator surface. The delivery of IORT is performed in the OR without the use of image-based planning. To overcome this limitation, we have generated sample DVH's and report dosimetric parameters to offer clinicians a unique dosimetric perspective. (c) 2019 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:E1 / E6
页数:6
相关论文
共 50 条
  • [1] Intraoperative Radiotherapy for Breast Cancer-A Single-Institution Experience
    Donovan, Cory
    Charlotte, Kubicky
    Pommier, SuEllen
    Naik, Arpana
    Vetto, John
    Gordon, Nicole
    Pommier, Rodney
    [J]. ANNALS OF SURGICAL ONCOLOGY, 2013, 20 : 37 - 38
  • [2] Dosimetric comparison of the INTRABEAM and Axxent for intraoperative breast radiotherapy
    Shaikh, Mubin Y.
    Tanny, Sean
    [J]. BRACHYTHERAPY, 2020, 19 (02) : 234 - 240
  • [3] INTRAOPERATIVE RADIOTHERAPY FOR PAROTID CANCER: A SINGLE-INSTITUTION EXPERIENCE
    Zeidan, Youssef H.
    Shiue, Kevin
    Weed, Daniel
    Johnstone, Peter A.
    Terry, Colin
    Freeman, Stephen
    Krowiak, Edward
    Borrowdale, Robert
    Huntley, Tod
    Yeh, Alex
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 82 (05): : 1831 - 1836
  • [4] INTRAOPERATIVE ELECTRON RADIOTHERAPY IN EARLY STAGE BREAST CANCER. A SINGLE-INSTITUTION EXPERIENCE
    Dall'Oglio, S.
    Maluta, S.
    Marciai, N.
    Gabbani, M.
    Franchini, Z.
    Pietrarota, P.
    Meliado, G.
    Guariglia, S.
    Cavedon, C.
    [J]. CANCER RESEARCH, 2012, 72
  • [5] Dosimetric evaluation of incorporating the revised V4.0 calibration protocol for breast intraoperative radiotherapy with the INTRABEAM system
    Shaikh, Mubin Y.
    Burmeister, Jay
    Scott, Robin
    Kumaraswami, Lalith K.
    Nalichowski, Adrian
    Joiner, Michael C.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (02): : 50 - 59
  • [6] Intraoperative radiotherapy using the Intrabeam® device as intraoperative boost in breast conserving therapy - a single institution experience after the first 200 cases
    Kolberg, H.
    Stephanou, M.
    Akpolat-Basci, L.
    Loevey, G.
    [J]. EUROPEAN JOURNAL OF CANCER, 2013, 49 : S452 - S452
  • [7] Intraoperative Radiotherapy With INTRABEAM: Technical and Dosimetric Considerations
    Sethi, Anil
    Emami, Bahman
    Small, William, Jr.
    Thomas, Tarita O.
    [J]. FRONTIERS IN ONCOLOGY, 2018, 8
  • [8] Intraoperative radiotherapy in early breast cancer - a single institution experience
    Steiner, M.
    Biterman, A.
    Shiloni, E.
    Leviov, M.
    Goldman, J.
    Front, A.
    Cederbaum, M.
    [J]. BREAST, 2011, 20 : S63 - S63
  • [9] Dosimetric Evaluation of the Intrabeam and Axxent System for Breast IORT
    Shaikh, M.
    Tanny, S.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E578 - E578
  • [10] Intraoperative radiotherapy (IORT) for breast cancer using the Intrabeam™ system
    Kraus-Tiefenbacher, U
    Scheda, A
    Steil, V
    Hermann, B
    Kehrer, T
    Bauer, L
    Melchert, F
    Wenz, F
    [J]. TUMORI, 2005, 91 (04) : 339 - 345