Test-retest reliability of the Mandarin versions of the Hypertension Self-Care Profile instrument

被引:14
|
作者
Ngoh, Soh Heng Agnes [1 ]
Lim, Hazel Wai Ling [2 ]
Koh, Yi Ling Eileen [1 ]
Tan, Ngiap Chuan [1 ,3 ]
机构
[1] SingHlth Polyclin, Dept Res, Singapore, Singapore
[2] Ngee Ann Polytech, Sch Hlth Sci, Singapore, Singapore
[3] Duke NUS Med Sch, Singapore, Singapore
关键词
hypertension; instrument; mandarin; self-care; CHRONIC DISEASE; EFFICACY;
D O I
10.1097/MD.0000000000008568
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Self-efficacy in essential hypertension can be measured using scales, such as the Hypertension Self-Care Profile (HTN-SCP) questionnaire. It assesses Behavior, Motivation, and Self-efficacy in 3 domains, respectively. This study aimed to validate the Mandarin version of HTN-SCP instrument (HTN-SCP-Mn) targeted at patients of Chinese ethnicity with hypertension.Our study recruited Chinese patients, aged 40 years and older, with essential hypertension from a public primary healthcare clinic in Singapore. The 60-item HTN-SCP-Mn questionnaire was completed online using a tablet or smartphone on enrolment. A retest was conducted 2 weeks after the initial test. Reliability was assessed by internal consistency and test-retest reliability using Cronbach alpha and intraclass correlation coefficients (ICC). Differences between the overall HTN-SCP-Mn scores of the patients and their self-reported self-management activities were also determined using independent t test.Of the 153 patients who completed the HTN-SCP-Mn during the initial test, 79 responded to the test-retest evaluation. Reliability of the 3 domains Behavior, Motivation, and Self-efficacy obtained high internal consistency (Cronbach alpha = 0.838, 0.929, and 0.927, respectively). The item total correlation ranged from 0.058 to 0.677 for Behavior, 0.374 to 0.798 for Motivation, and 0.326 to 0.767 for self-efficacy. The ICC indicated fair to good test-retest reliability with scores of 0.643, 0.579, and 0.710 for the respective domains.The results showed face validity of the HTN-SCP-Mn instrument, indicating its potential application in mandarin-proficient patients. Further study is needed to correlate its scores with objective demonstration of self-efficacy.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Cluster analysis for test-retest Reliability
    Roy, Debdulal Dutta
    INTERNATIONAL JOURNAL OF PSYCHOLOGICAL RESEARCH, 2010, 3 (01): : 131 - 139
  • [42] THE TEST-RETEST RELIABILITY OF QUALITATIVE DATA
    Guttman, Louis
    PSYCHOMETRIKA, 1946, 11 (02) : 81 - 95
  • [43] Test-retest reliability of functional MRI
    Tallent, KA
    Ramsey, NF
    Frank, JA
    Moonen, CT
    Weinberger, DR
    INTERNATIONAL JOURNAL OF PSYCHOLOGY, 1996, 31 (3-4) : 12451 - 12451
  • [44] An Investigation of the Test-Retest Reliability of the miniPXI
    Haider, Aqeel
    Wallner, Günter
    Gerling, Kathrin
    Vanden Abeele, Vero
    Proceedings of the ACM on Human-Computer Interaction, 2024, 8 (CHI PLAY)
  • [45] SKEW REDUCES TEST-RETEST RELIABILITY
    DUNLAP, WP
    CHEN, RS
    GREER, T
    JOURNAL OF APPLIED PSYCHOLOGY, 1994, 79 (02) : 310 - 313
  • [46] A BASIS FOR ANALYZING TEST-RETEST RELIABILITY
    Guttman, Louis
    PSYCHOMETRIKA, 1945, 10 (04) : 255 - 282
  • [47] Test-retest reliability in Electroencephalographic Recordings
    Ximena Suarez-Revelo, Jazmin
    Fredy Ochoa-Gomez, John
    Duque-Grajales, Jon
    Montoya-Betancur, Alejandro
    Sanchez-Lopez, Sebastian
    2015 20TH SYMPOSIUM ON SIGNAL PROCESSING, IMAGES AND COMPUTER VISION (STSIVA), 2015,
  • [48] Test-retest reliability of loudness scaling
    Robinson, K
    Gatehouse, S
    EAR AND HEARING, 1996, 17 (02): : 120 - 123
  • [49] TEST-RETEST RELIABILITY OF THE IDEA INVENTORY
    VESTRE, ND
    PSYCHOLOGICAL REPORTS, 1984, 54 (03) : 873 - 874
  • [50] Test-Retest Reliability of Electroglottography Measurement
    Cangi, Mehmet Emrah
    Yilmaz, Goksu
    JOURNAL OF ACADEMIC RESEARCH IN MEDICINE-JAREM, 2021, 11 (02): : 126 - 136