Evaluation of the in vitro cytotoxicity and modulation of the inflammatory response by the bioresorbable polymers poly(D,L-lactide-co-glycolide) and poly(L-lactide-co-glycolide)

被引:11
|
作者
Geddes, Lucy [1 ]
Themistou, Efrosyni [2 ]
Burrows, James F. [3 ]
Buchanan, Fraser J. [1 ]
Carson, Louise [3 ]
机构
[1] Queens Univ Belfast, Sch Mech & Aerosp Engn, Ashby Bldg, Belfast BT9 5AG, Antrim, North Ireland
[2] Queens Univ Belfast, Sch Chem & Chem Engn, David Keir Bldg, Belfast BT9 5AG, Antrim, North Ireland
[3] Queens Univ Belfast, Sch Pharm, Belfast BT9 7BL, Antrim, North Ireland
关键词
Poly(lactide-co-glycolide); Biocompatibility; Cytotoxicity; Quasi Vivo; Lactate; Hydroxycarboxylic acid receptor 1; HCA1; FOREIGN-BODY REACTION; BIOABSORBABLE INTERFERENCE SCREWS; CRUCIATE LIGAMENT RECONSTRUCTION; PATELLAR TENDON GRAFT; L-LACTIDE; TISSUE-RESPONSE; DEGRADATION; LACTATE; IMPLANTS; BIOCOMPATIBILITY;
D O I
10.1016/j.actbio.2021.07.049
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Bioresorbable polymers composed of poly(D,L-lactide-co-glycolide) (PDLLGA) and poly(L-lactide-co-glycolide) (PLLGA) have become increasingly popular for the preparation of bone substitute constructs. However, there are reports of a delayed inflammatory reaction occurring months or years after implanta-tion. Due to the long polymer degradation times, in vitro tests carried out at physiological temperature, 37 degrees C, tend to assess only the short-term biocompatibility of these materials. The aim of this work is to de-velop an in vitro protocol that can be used to assess the long-term cytotoxicity of bioresorbable polymers in a time efficient manner. This study used a previously developed and validated accelerated degradation protocol to obtain samples of PDLLGA and PLLGA at increasing levels of degradation. Samples were then applied to standard ISO 10993-5 direct contact cytotoxicity testing and it was found that PDLLGA samples showed increasing levels of cytotoxicity at the later stages of degradation, with PLLGA samples demon-strating significantly less cytotoxic behaviour. Following concern that accumulation of acidic degradation products in a closed multi-well culture environment could overestimate cytotoxicity, we developed and validated a new dynamic flow culture methodology, for testing the cytotoxicity of these degradable materials, by adapting a commercial "organ on a chip" flow culture system, Quasi Vivo (R). In addition to cytotoxicity testing, we have carried out profiling of inflammatory cytokines released by cells in response to degraded PDLLGA and PLLGA, and have suggested mechanism by which lactide-based bioresorbable materials could modulate the inflammatory response through the G-protein coupled receptor (GPCR), hy-droxycarboxylic acid receptor 1 (HCA1). Statement of significance Bioresorbable materials naturally disintegrate over time when implanted into the body. They are often used to make screws and clips for repair of broken bones. Unfortunately, some patients can react badly to the material, resulting in painful inflammation. Biomaterials scientists are interested in developing materials that are more compatible with the body. However, it is very difficult to predict the long-term compatibility of bioresorbable materials in the lab. In our study, we have developed a method that will allow us to study the effects of the materials as they continue to break down. This will help us understand why the materials may cause inflammation, and will support research into the development of new and improved materials for bone repair. (c) 2021 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
引用
下载
收藏
页码:261 / 275
页数:15
相关论文
共 50 条
  • [21] Dimensional stability of electrospun membranes of poly(l-lactide-co-glycolide)/poly(l-lactide-co-glycolide)-b-polyethylene glycol blends under stretch
    Chi Ma
    Bing Wang
    Cheng-Dong Xiong
    Dong-Liang Chen
    Zuo-Chun Xiong
    Journal of Polymer Research, 2012, 19
  • [22] Structure and cytotoxicity of biodegradable poly(D,l-lactide-co-glycolide) nanoparticles loaded with oxaliplatin
    Razuvaeva, Ekaterina, V
    Kalinin, Kirill T.
    Sedush, Nikita G.
    Nazarov, Alexey A.
    Volkov, Dmitry S.
    Chvalun, Sergei N.
    MENDELEEV COMMUNICATIONS, 2021, 31 (04) : 512 - 514
  • [23] Dimensional stability of electrospun membranes of poly(L-lactide-co-glycolide)/poly(L-lactide-co-glycolide)-b-polyethylene glycol blends under stretch
    Ma, Chi
    Wang, Bing
    Xiong, Cheng-Dong
    Chen, Dong-Liang
    Xiong, Zuo-Chun
    JOURNAL OF POLYMER RESEARCH, 2012, 19 (12)
  • [24] Measurement of protein diffusion through poly(D,L-lactide-co-glycolide)
    Fredenberg, S
    Reslow, M
    Axelsson, A
    PHARMACEUTICAL DEVELOPMENT AND TECHNOLOGY, 2005, 10 (02) : 299 - 307
  • [25] Biocompatibility of poly(D,L-lactide-co-glycolide) nanoparticles conjugated with alendronate
    Cenni, Elisabetta
    Granchi, Donatella
    Avnet, Sofia
    Fotia, Caterina
    Salerno, Manuela
    Micieli, Dorotea
    Sarpietro, Maria G.
    Pignatello, Rosario
    Castelli, Francesco
    Baldini, Nicola
    BIOMATERIALS, 2008, 29 (10) : 1400 - 1411
  • [26] Clonazepam microencapsulation in poly-D,L-lactide-co-glycolide microspheres
    Benelli, P
    Conti, B
    Genta, I
    Costantini, M
    Montanari, L
    JOURNAL OF MICROENCAPSULATION, 1998, 15 (04) : 431 - 443
  • [27] Formulation and In vitro Evaluation of Ibuprofen-Loaded Poly(D,L-lactide-co-glycolide) Microparticles
    Momoh, M. A.
    Adedokun, M. O.
    Lawal, S. B.
    Ubochi, G. O.
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2014, 13 (10) : 1571 - 1576
  • [28] Biodegradation of poly(L-lactide-co-glycolide) tube stents in bile
    Xu, Xiaoyi
    Liu, Tongiun
    Zhang, Kai
    Liu, Shaohui
    Shen, Zhen
    Li, Yuxin
    Jing, Xiabin
    POLYMER DEGRADATION AND STABILITY, 2008, 93 (04) : 811 - 817
  • [29] In vitro degradation behavior of L-lactide/trimethylene carbonate/glycolide terpolymers and a composite with poly(L-lactide-co-glycolide) fibers
    Liao, Lan
    Dong, Jianting
    Shi, Li
    Fan, Zhongyong
    Li, Suming
    Lu, Zhiqian
    POLYMER DEGRADATION AND STABILITY, 2015, 111 : 203 - 210
  • [30] Thermosensitive poly-(D,L-lactide-co-glycolide)-block-poly(ethylene glycol)-block-poly-(D, L-lactide-co-glycolide) hydrogels for multi-drug delivery
    Cho, Hyunah
    Kwon, Glen S.