A novel paper-based assay for the simultaneous determination of Rh typing and forward and reverse ABO blood groups

被引:48
|
作者
Noiphung, Julaluk [1 ]
Talalak, Kwanrutai [1 ]
Hongwarittorrn, Inn [1 ]
Pupinyo, Naricha [2 ]
Thirabowonkitphithan, Pannawich [2 ]
Laiwattanapaisal, Wanida [3 ]
机构
[1] Chulalongkorn Univ, Fac Allied Hlth Sci, Grad Program Clin Biochem & Mol Med, Bangkok 10330, Thailand
[2] Chulalongkorn Univ, Fac Allied Hlth Sci, Undergrad Program Med Technol, Bangkok 10330, Thailand
[3] Chulalongkorn Univ, Fac Allied Hlth Sci, Dept Clin Chem, Bangkok 10330, Thailand
来源
关键词
ABO blood group; Forward and reverse typing; Haemagglutination; Paper-based analytical devices (PADs); Rh typing; Wax dipping; LOW-COST; DEVICE; WAX; MICROFLUIDICS; SYSTEM;
D O I
10.1016/j.bios.2014.09.011
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
We propose a new, paper-based analytical device (PAD) for blood typing that allows for the simultaneous determination of ABO and Rh blood groups on the same device. The device was successfully fabricated by using a combination of wax printing and wax dipping methods. A 1:2 blood dilution was used for forward grouping, whereas whole blood could be used for reverse grouping. A 30% cell suspension of A-cells or B-cells was used for haemagglutination on the reverse grouping side. The total assay time was 10 min. The ratio between the distance of red blood cell movement and plasma separation is the criterion for agglutination and indicates the presence of the corresponding antigen or antibody. The proposed PAD has excellent reproducibility in that the same blood groups, namely A, AB, and 0, were reported by using different PADs that were fabricated on the same day (n=10). The accuracy for detecting blood group A (n=12), B (n=13), AB (n=9), 0 (n=14), and Rh (n=48) typing were 92%, 85%, 89%, 93%, and 96%, respectively, in comparison with the conventional slide test method. The haematocrit of the sample affects the accuracy of the results, and appropriate dilution is suggested before typing. In conclusion, this study proposes a novel method that is straightforward, time-saving, and inexpensive for the simultaneous determination of ABO and Rh blood groups, which is promising for use in developing countries. (C) 2014 Elsevier B.V. All rights reserved.
引用
下载
收藏
页码:485 / 489
页数:5
相关论文
共 50 条
  • [31] Microfluidic paper-based chemiluminescence biosensor for simultaneous determination of glucose and uric acid
    Yu, Jinghua
    Ge, Lei
    Huang, Jiadong
    Wang, Shoumei
    Ge, Shenguang
    LAB ON A CHIP, 2011, 11 (07) : 1286 - 1291
  • [32] Paper-Based Assay for Quantification of HbS in Blood of Sickle Cell Disease Patients
    Piety, Nathaniel Z.
    Yang, Xiaoxi
    Dinu, Bogdan R.
    George, Alex
    Shevkoplyas, Sergey S.
    BLOOD, 2014, 124 (21)
  • [33] The Potential and Pitfalls of a Dye-Assisted Paper-Based Assay for Blood Grouping
    Sloan, Steven R.
    CLINICAL CHEMISTRY, 2018, 64 (03) : 429 - 430
  • [34] A Paper-Based Assay for the Determination of Total Antioxidant Capacity in Human Serum Samples
    Tran, Michelle T.
    Gomez, Sophia V.
    Alenicheva, Vera
    Remcho, Vincent T.
    Biosensors, 2024, 14 (11):
  • [35] Integrated microfluidic paper-based system for determination of whole blood albumin
    Yang, Ruey-Jen
    Tseng, Chin-Chung
    Ju, Wei-Jhong
    Fu, Lung-Ming
    Syu, Meng-Ping
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 273 : 1091 - 1097
  • [36] Paper-based colorimetric enzyme linked immunosorbent assay fabricated by laser induced forward transfer
    Katis, Ioannis N.
    Holloway, Judith A.
    Madsen, Jens
    Faust, Saul N.
    Garbis, Spiros D.
    Smith, Peter J. S.
    Voegeli, David
    Bader, Dan L.
    Eason, Robert W.
    Sones, Collin L.
    BIOMICROFLUIDICS, 2014, 8 (03):
  • [37] Portable paper-based device for ABO and RhD typing using smartphone interpretation: Optical answer sheet reading concept
    Chomean, Sirinart
    Ingkananth, Suparada
    Kiatchaipar, Methasit
    Kaset, Chollanot
    ANALYTICA CHIMICA ACTA, 2021, 1180
  • [38] Simultaneous Determination Of BUN-Creatinine as Kidney Function Biomarkers in Blood using a Microfluidic Paper-based Analytical Devices
    Mahdiasanti, I. W.
    Sabarudin, Akhmad
    Sulistyarti, Hermin
    9TH ANNUAL BASIC SCIENCE INTERNATIONAL CONFERENCE 2019 (BASIC 2019), 2019, 546
  • [39] A novel paper-based colorimetry device for the determination of the albumin to creatinine ratio
    Chaiyo, Sudkate
    Kalcher, Kurt
    Apilux, Amara
    Chailapakul, Orawon
    Siangproh, Weena
    ANALYST, 2018, 143 (22) : 5453 - 5460
  • [40] A novel wireless paper-based potentiometric platform for monitoring glucose in blood
    Canovas, Rocio
    Parrilla, Marc
    Blondeau, Pascal
    Andrade, Francisco J.
    LAB ON A CHIP, 2017, 17 (14) : 2500 - 2507