摘要
Blood glucose management is one of the important therapies in the intensive care unit (ICU). However, blood glucose management using the sliding-scale method increases the workload of ICU nurses. An artificial pancreas, STG-22, has been developed to continuously monitor blood glucose levels and to maintain them at appropriate levels. In this study, we examined the hypothesis that compared to conventional methods, blood glucose management using the STG-22 reduces the workload of ICU nurses and has a positive impact on awareness regarding the management of blood glucose. This study included 45 patients who underwent elective surgery and were treated at the ICU postoperatively. The patients were separated into the following two groups: (1) blood glucose was maintained using the STG-22 (AP group) and (2) blood glucose was maintained using the sliding-scale method (SS group). In addition, a questionnaire was developed for an awareness survey of ICU nurses (N = 20). The frequency of blood sampling and number of double checks were significantly lower in the AP group (1.3 +/- 1.4 vs. 8.9 +/- 8.1 times/admission, P < 0.001; 1.0 +/- 1.4 vs. 9.8 +/- 8.5 times/admission, P < 0.001). The time needed for glucose management per admission was significantly shorter in the AP group (9 +/- 13 vs. 27 +/- 24 min/admission; P = 0.003). Use of STG-22 for glucose management in the ICU increased the degree of attention given by nurses to glucose management and contributed to an improved sense of security. In conclusion, using the STG-22 in the ICU reduces the workload of ICU nurses compared to using the sliding-scale method. It also contributed to the reduction of the ICU nurses' anxiety related to the management of blood glucose.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 50 条
  • [21] Blood Glucose Control Using a Novel Continuous Blood Glucose Monitor and Repetitive Intravenous Insulin Boluses: Exploiting Natural Insulin Pulsatility as a Principle for a Future Artificial Pancreas
    Skjaervold, Nils K.
    Ostling, Dan
    Hjelme, Dag R.
    Spigset, Olav
    Lyng, Oddveig
    Aadahl, Petter
    INTERNATIONAL JOURNAL OF ENDOCRINOLOGY, 2013, 2013
  • [22] Tight blood glucose control in the ICU - How best to measure glucose control?
    Hoo, Guy W. Soo
    CHEST, 2008, 133 (01) : 316 - 317
  • [23] A case of perioperative glucose control by using an artificial pancreas in a patient with glycogen storage disease
    Yatabe, Tomoaki
    Nakamura, Ryu
    Kitagawa, Hiroyuki
    Munekage, Masaya
    Hanazaki, Kazuhiro
    JOURNAL OF ARTIFICIAL ORGANS, 2016, 19 (01) : 100 - 103
  • [24] A case of perioperative glucose control by using an artificial pancreas in a patient with glycogen storage disease
    Tomoaki Yatabe
    Ryu Nakamura
    Hiroyuki Kitagawa
    Masaya Munekage
    Kazuhiro Hanazaki
    Journal of Artificial Organs, 2016, 19 : 100 - 103
  • [25] Analysis of perioperative glucose metabolism using an artificial pancreas
    Okazaki, Mitsuyoshi
    Hayashi, Hironori
    Gabata, Ryousuke
    Ohbatake, Yoshinao
    Shinbashi, Hiroyuki
    Nakanuma, Shinichi
    Makino, Isamu
    Tajima, Hidehiro
    Takamura, Hiroyuki
    Ohta, Tetsuo
    ARTIFICIAL ORGANS, 2021, 45 (09) : 998 - 1005
  • [26] Evaluation of a Novel Artificial Pancreas: Closed Loop Glycemic Control System With Continuous Blood Glucose Monitoring
    Tsukamoto, Yuuki
    Kinoshita, Yoshihiko
    Kitagawa, Hiroyuki
    Munekage, Masaya
    Munekage, Eri
    Takezaki, Yuka
    Yatabe, Tomoaki
    Yamashita, Koichi
    Yamazaki, Rie
    Okabayashi, Takehiro
    Tarumi, Masatoshi
    Kobayashi, Masaki
    Mishina, Suguru
    Hanazaki, Kazuhiro
    ARTIFICIAL ORGANS, 2013, 37 (04) : E67 - E73
  • [27] Tight blood glucose control in the ICU - How best to measure glucose control? Response
    Vanhorebeek, Ilse
    Van den Berghe, Greet
    CHEST, 2008, 133 (01) : 317 - 317
  • [28] Investigation of insulin clearance in septic patients with glucose intolerance: analysis under strict blood glucose control by means of artificial pancreas
    M Hoshino
    Y Haraguchi
    M Sakai
    K Hayashi
    N Miyayama
    H Saegusa
    H Ohsawa
    Critical Care, 5 (Suppl 1):
  • [29] Evaluation of artificial pancreas technology for continuous blood glucose monitoring in dogs
    Mori, Akihiro
    Lee, Peter
    Yokoyama, Takeshi
    Oda, Hitomi
    Saeki, Kaori
    Miki, Yohei
    Nozawa, Satoshi
    Azakami, Daigo
    Momota, Yutaka
    Makino, Yuki
    Matsubara, Takako
    Osaka, Motohisa
    Ishioka, Katsumi
    Arai, Toshiro
    Sako, Toshinori
    JOURNAL OF ARTIFICIAL ORGANS, 2011, 14 (02) : 133 - 139
  • [30] GLUCAGON AND BLOOD-GLUCOSE - INSIGHTS FROM ARTIFICIAL PANCREAS STUDIES
    FELIG, P
    SHERWIN, RS
    ANNALS OF INTERNAL MEDICINE, 1980, 92 (06) : 856 - 857