Blood glucose control using an artificial pancreas reduces the workload of ICU nurses

被引:19
|
作者
Mibu, Kiyo [1 ]
Yatabe, Tomoaki [2 ]
Hanazaki, Kazuhiro [3 ]
机构
[1] Kochi Med Sch Hosp, Dept Nursing, Nankoku, Kochi 7838505, Japan
[2] Kochi Med Sch, Dept Anesthesiol & Crit Care Med, Nankoku, Kochi 7838505, Japan
[3] Kochi Med Sch, Dept Surg, Nankoku, Kochi 7838505, Japan
关键词
Artificial pancreas; Workload; Intensive care unit; INTENSIVE INSULIN THERAPY; ERRORS;
D O I
10.1007/s10047-011-0611-7
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Blood glucose management is one of the important therapies in the intensive care unit (ICU). However, blood glucose management using the sliding-scale method increases the workload of ICU nurses. An artificial pancreas, STG-22, has been developed to continuously monitor blood glucose levels and to maintain them at appropriate levels. In this study, we examined the hypothesis that compared to conventional methods, blood glucose management using the STG-22 reduces the workload of ICU nurses and has a positive impact on awareness regarding the management of blood glucose. This study included 45 patients who underwent elective surgery and were treated at the ICU postoperatively. The patients were separated into the following two groups: (1) blood glucose was maintained using the STG-22 (AP group) and (2) blood glucose was maintained using the sliding-scale method (SS group). In addition, a questionnaire was developed for an awareness survey of ICU nurses (N = 20). The frequency of blood sampling and number of double checks were significantly lower in the AP group (1.3 +/- 1.4 vs. 8.9 +/- 8.1 times/admission, P < 0.001; 1.0 +/- 1.4 vs. 9.8 +/- 8.5 times/admission, P < 0.001). The time needed for glucose management per admission was significantly shorter in the AP group (9 +/- 13 vs. 27 +/- 24 min/admission; P = 0.003). Use of STG-22 for glucose management in the ICU increased the degree of attention given by nurses to glucose management and contributed to an improved sense of security. In conclusion, using the STG-22 in the ICU reduces the workload of ICU nurses compared to using the sliding-scale method. It also contributed to the reduction of the ICU nurses' anxiety related to the management of blood glucose.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 50 条
  • [1] Blood glucose control using an artificial pancreas reduces the workload of ICU nurses
    Kiyo Mibu
    Tomoaki Yatabe
    Kazuhiro Hanazaki
    Journal of Artificial Organs, 2012, 15 : 71 - 76
  • [2] CONTROL OF BLOOD-GLUCOSE IN DIABETICS USING AN ARTIFICIAL PANCREAS
    KRAEGEN, EW
    CAMPBELL, LV
    CHIA, YO
    MELER, H
    LAZARUS, L
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1977, 7 (03): : 280 - 286
  • [3] Blood Glucose Regulation using an Implantable Artificial Pancreas
    Chui, Chee-Kong
    2015 IEEE 13TH INTERNATIONAL SYMPOSIUM ON APPLIED MACHINE INTELLIGENCE AND INFORMATICS (SAMI), 2015, : 11 - 11
  • [4] EVALUATING REWARD FUNCTIONS FOR BLOOD GLUCOSE CONTROL USING REINFORCEMENT LEARNING IN THE ARTIFICIAL PANCREAS
    Hernandez, M. Tejedor
    Myhre, J.
    Launonen, I.
    Godtliebsen, F.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2020, 22 : A86 - A86
  • [5] EFFECTIVENESS OF A NOVEL ARTIFICIAL PANCREAS STG-55 ON THE WORKLOAD OF NURSES
    Mibu, K.
    Kitagawa, H.
    Munekage, M.
    Yatabe, T.
    Yamasaki, F.
    Hanazaki, K.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2013, 15 : A96 - A97
  • [6] Reducing Risk of Closed Loop Control of Blood Glucose in Artificial Pancreas using Fractional Calculus
    Ghorbani, Mahboobeh
    Bogdan, Paul
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 4839 - 4842
  • [7] BLOOD-GLUCOSE CONTROL BY AN ARTIFICIAL ENDOCRINE PANCREAS IN A PATIENT WITH PHEOCHROMOCYTOMA
    HAMAJI, M
    MIYATA, M
    KAWAMORI, R
    SHICHIRI, M
    MASHIMO, T
    NAKAO, K
    KAWASHIMA, Y
    CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1985, 32 (05) : 538 - 542
  • [8] Feasibility of Automated Ambulatory Blood Glucose Control in Type 1 Diabetes Using a Wearable Artificial Pancreas
    Renard, Eric
    Cobelli, Claudio
    Kovatchev, Boris P.
    Keith-Hynes, Patrick
    Ben Brahim, Najib
    Place, Jerome
    Simone, Del Favero
    Breton, Marc
    Farret, Anne
    Bruttomesso, Daniela
    Patek, Stephen D.
    Avogaro, Angelo
    DIABETES, 2012, 61 : A231 - A231
  • [9] Comparison of control algorithms for the blood glucose concentration in a virtual patient with an artificial pancreas
    Semizer, E.
    Yuceer, M.
    Atasoy, I.
    Berber, R.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2012, 90 (07): : 926 - 937
  • [10] An artificial pancreas for automated blood glucose control in patients with Type 1 diabetes
    Schmidt, Signe
    Boiroux, Dimitri
    Ranjan, Ajenthen
    Jorgensen, John Bagterp
    Madsen, Henrik
    Norgaard, Kirsten
    THERAPEUTIC DELIVERY, 2015, 6 (05) : 609 - 619