A virtual supply airflow rate meter for rooftop air-conditioning units

被引:46
|
作者
Yu, Daihong [1 ]
Li, Haorong [1 ]
Yang, Mo [1 ]
机构
[1] Univ Nebraska Lincoln, Dept Architectural Engn, Omaha, NE 68182 USA
关键词
Virtual sensing technology; Virtual calibration methodology; Rooftop air-conditioning units; Airflow rate; Fault detection and diagnosis; FAULT-DETECTION; SENSORS; TEMPERATURE;
D O I
10.1016/j.buildenv.2010.12.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A proper amount of supply airflow is critical in all kinds of air-based HVAC systems to maintain desired control effectiveness, energy efficiency and indoor air quality (IAQ). Although knowledge of supply airflow rate (SCFM) is certainly very important, measuring and monitoring SCFM in rooftop air-conditioning units (RTUs) by using the conventional SCFM metering devices are very costly and more than often problematic. This paper proposes a low-cost but accurate virtual SCFM meter to solve the dilemma for RTUs. The SCFM values are indirectly derived from a first-principle model in combination with accurate measurements of low-cost virtual or virtually calibrated temperature sensors. Modeling, uncertainty analysis and experimental evaluation through a wide range of laboratory testing for both cooling- and heating-based approaches are performed respectively in the development. The study reveals that the heating-based method surpasses the other in terms of its simplicity, accuracy (uncertainty is +/- 6.9% vs +/- 13.8%) and reliability and is chosen to be the virtual SCFM meter in RTUs. This cost-effective application is promising with a number of merits, such as easy to implement, economical for use, and generic in RTUs with the same constructed gas furnaces. For applications, it could be applied as a permanently installed monitoring tool to indicate the SCFM and/or to automatically detect and diagnose improper quantity of SCFM for RTUs. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1292 / 1302
页数:11
相关论文
共 50 条
  • [31] A procedure to analyse airflow in automotive air-conditioning systems in an early stage of design
    Hofhaus, J
    Didandeh, H
    VTMS 4: VEHICLE THERMAL MANAGEMENT SYSTEMS, 1999, : 81 - 90
  • [32] Impact of nasal septal perforation on the airflow and air-conditioning characteristics of the nasal cavity
    Na, Yang
    Kwon, Kyung Won
    Jang, Yong Ju
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [33] Numerical simulation of airflow and concentration fields in air-conditioning vehicle passenger compartment
    Xiang, Li-Ping
    Wang, Han-Qing
    Zhongnan Daxue Xuebao (Ziran Kexue Ban)/Journal of Central South University (Science and Technology), 2010, 41 (05): : 2017 - 2021
  • [34] AIR-CONDITIONING UNIT HEATS DOMESTIC WATER-SUPPLY
    BAK, DJ
    DESIGN NEWS, 1979, 35 (09) : 22 - 22
  • [35] Interaction Analysis Investigations of Multiple Supply Duct Split-type Air-conditioning units in an Open Space
    Widsonkun, W.
    Woradechjumroen, D.
    Vongbunyong, S.
    9TH THAI SOCIETY OF MECHANICAL ENGINEERS, INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING (TSME-ICOME 2018), 2019, 501
  • [36] Aggregated large-scale air-conditioning load: Modeling and response capability evaluation of virtual generator units
    Wang, Jingjie
    Qiu, Rujia
    Xu, Bin
    Wu, Hongbin
    Tang, Longjiang
    Zhang, Mingxing
    Ding, Ming
    ENERGY, 2023, 276
  • [37] Ant-nest corrosion of copper tubing in air-conditioning units
    Bastidas, D.M.
    Cayuela, I.
    Bastidas, J.M.
    Revista de Metalurgia (Madrid), 2006, 42 (05): : 367 - 381
  • [38] Study of Air-Conditioning Load: Comparison of Steel and RC Residence Units
    Wang, Yupeng
    Fukuda, Hiroatsu
    Kuma, Yuko
    Ozaki, Akihito
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2010, 9 (02) : 571 - 576
  • [39] Early corrosion failure of copper tubing used in air-conditioning units
    Cano, E
    Simancas, J
    Polo, JL
    Torres, CL
    Bastidas, JM
    Alcolea, J
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 1999, 50 (02): : 103 - 110
  • [40] Ant-nest corrosion of copper tubing in air-conditioning units
    Bastidas, D. M.
    Cayuela, I.
    Bastidas, J. M.
    REVISTA DE METALURGIA, 2006, 42 (05) : 367 - 381