Sensitivity of design parameters on energy, system and comfort performances for radiant cooled office buildings in the tropics

被引:1
|
作者
Talami, Riccardo [1 ]
Jakubiec, J. Alstan [2 ]
机构
[1] Loughborough Univ, Sch Architecture Bldg & Civil Engn, Loughborough, Leics, England
[2] Univ Toronto, Daniels Fac Architecture Landscape & Design, Toronto, ON, Canada
基金
新加坡国家研究基金会;
关键词
MODELS;
D O I
10.26868/25222708.2019.210315
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The research community has worked on optimizing the design, performance, and operation of radiant system technologies; however, the holistic interactions between architectural design decisions and radiant cooling systems design in the tropics have been left unexplored. Morris sensitivity analysis is used to analyze the design performance impact, interactions, variability and nonlinear effects of 13 building and systems design parameters on energy, system and comfort performances for 3 radiant systems typologies applied to a parametric office building in the tropical climate of Singapore. It is found that window solar heat gain coefficient, window-to-wall ratio, and system set-point temperature play a key role to ensure building's high multi-objective performance and have an almost monotonic behavior with respective values falling below or equal to 54% and 57% and high room dry bulb air temperatures between 24.8 degrees C and 27 degrees C.
引用
收藏
页码:1786 / 1793
页数:8
相关论文
共 50 条
  • [21] Design of low energy office buildings
    Gratia, E
    De Herde, A
    [J]. ENERGY AND BUILDINGS, 2003, 35 (05) : 473 - 491
  • [22] Influence of design parameters on the night ventilation performance in office buildings based on sensitivity analysis
    Guo, Rui
    Hu, Yue
    Liu, Mingzhe
    Heiselberg, Per
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2019, 50
  • [23] Thermal comfort and IAQ analysis of a decentralized DOAS system coupled with radiant cooling for the tropics
    Saber, Esmail M.
    Iyengar, Rupesh
    Mast, Matthias
    Meggers, Forrest
    Tham, Kwok Wai
    Leibundgut, Hansjuerg
    [J]. BUILDING AND ENVIRONMENT, 2014, 82 : 361 - 370
  • [24] A Simplified Thermal Comfort Calculation Method of Radiant Floor Cooling Technology for Office Buildings in Northern China
    Wang, Xiaolong
    Mu, Tian
    Zhang, Lili
    Zhang, Wenke
    Zhang, Linhua
    [J]. BUILDINGS, 2022, 12 (04)
  • [25] On the Application of Clustering Techniques for Office Buildings' Energy and Thermal Comfort Classification
    Nikolaou, Triantafyllia G.
    Kolokotsa, Dionysia S.
    Stavrakakis, George S.
    Skias, Ioannis D.
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2012, 3 (04) : 2196 - 2210
  • [26] Energy efficient thermal comfort in open-plan office buildings
    Nagarathinam, Srinarayana
    Doddi, Harish
    Vasan, Arunchandar
    Sarangan, Venkatesh
    Ramakrishna, Venkata P.
    Sivasubramaniam, Anand
    [J]. ENERGY AND BUILDINGS, 2017, 139 : 476 - 486
  • [27] Effects of weather forecasting on indoor comfort and energy savings in office buildings
    Chen, Tai-Jen George
    Liu, Yi-Ting
    Lee, Chia-Yi
    Chang, Yang-Chien Wim
    Cheng, Chia-Ping
    Lee, Ming-Hao
    Chan, Yi-Chieh
    Huang, Jen-Chieh
    Chao, Kung-Yueh Camyale
    [J]. BUILDING AND ENVIRONMENT, 2022, 221
  • [28] Energy consequences of Comfort-driven temperature setpoints in office buildings
    Aryal, Ashrant
    Becerik-Gerber, Burcin
    [J]. ENERGY AND BUILDINGS, 2018, 177 : 33 - 46
  • [29] Energy efficient design of large office buildings
    Radford, J
    Addison, MS
    Smith, T
    [J]. BUILDING FOR THE 21ST CENTURY: ENERGY & THE ENVIRONMENT, 2000, : 125 - 130
  • [30] Energy efficiency and thermal comfort characteristics of convection-radiation combined cooling system in office buildings
    Liu, Dong
    Liu, Na
    Li, Guanyu
    Wu, Xiaozhou
    Wang, Jun
    Tian, Yabin
    Zhang, Qing
    Hu, Anjie
    Wen, Jialan
    [J]. JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2024, 38 (05) : 2649 - 2660