Detection of L-nicotine with dissipation mode quartz crystal microbalance using molecular imprinted polymers

被引:9
|
作者
Alenus, Jan [1 ]
Galar, Pavel [2 ]
Ethirajan, Anitha [1 ]
Horemans, Frederik [1 ]
Weustenraed, Ans [1 ]
Cleij, Thomas J. [1 ]
Wagner, Patrick [1 ,3 ]
机构
[1] Hasselt Univ, Inst Mat Res IMO, B-3590 Diepenbeek, Belgium
[2] Charles Univ Prague, Fac Math & Phys, CR-12116 Prague 2, Czech Republic
[3] IMEC Div IMOMEC, B-3590 Diepenbeek, Belgium
关键词
aqueous fluids; dissipation detection; L-nicotine; molecular imprinted polymer; quartz crystal microbalance; SENSOR; HISTAMINE;
D O I
10.1002/pssa.201100768
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Synthetic materials with imprinted nanocavities can act as highly selective tailor-made artificial receptors. Implementing these materials in a piezoelectric sensing device can offer fast and straightforward detection together with high sensitivity. L-nicotine, a major addictive substance in cigarettes is used as target molecule. The synthetic receptors for L-nicotine are made via the molecular imprinting technique. The target molecule is added to a monomer mixture containing initiator and this mixture is polymerized with heat. Subsequently, microparticles are obtained by crushing the bulk molecular imprinted polymers (MIPs), which are then immobilized on thin films of polyvinyl chloride. Using Quartz crystal microbalance, L-nicotine could be detected in the submicromolar range and the selectivity of the sensors was verified by reference measurements with L-cotinine. The effectiveness of the sensor was also tested for different aqueous fluids at different pH. It was found that MIPs bind 4.03 times more L-nicotine than non-imprinted polymer in water and 1.99 times more in 0.1 x phosphate buffer saline at pH 9. (c) 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim
引用
收藏
页码:905 / 910
页数:6
相关论文
共 50 条
  • [21] Acoustic Immunosensing of Exosomes Using a Quartz Crystal Microbalance with Dissipation Monitoring
    Suthar, Jugal
    Parsons, Edward S.
    Hoogenboom, Bart W.
    Williams, Gareth R.
    Guldin, Stefan
    ANALYTICAL CHEMISTRY, 2020, 92 (05) : 4082 - 4093
  • [22] Viscoelastic study of conducting polymers using Quartz Crystal Microbalance
    Samani, Mehrdad Bahrami
    Whitten, Philip
    Spinks, Geoffrey
    Cook, Christopher
    SMART STRUCTURES AND MATERIALS 2006: ELECTROACTIVE POLYMER ACTUATORS AND DEVICES (EAPAD), 2006, 6168
  • [23] Actomyosin motility detection using Quartz Crystal Microbalance
    Hanson, KL
    Viidyanathan, V
    Nicolau, DV
    BIOMEMS AND NANOTECHNOLOGY II, 2006, 6036
  • [24] Dual-Mode and Label-Free Detection of Exosomes from Plasma Using an Electrochemical Quartz Crystal Microbalance with Dissipation Monitoring
    Suthar, Jugal
    Prieto-Simon, Beatriz
    Williams, Gareth R.
    Guldin, Stefan
    ANALYTICAL CHEMISTRY, 2022, 94 (05) : 2465 - 2475
  • [25] The detection of Pseudomonas aeruginosa using the quartz crystal microbalance
    Bovenizer, JS
    Jacobs, MB
    O'Sullivan, CK
    Guilbault, GG
    ANALYTICAL LETTERS, 1998, 31 (08) : 1287 - 1295
  • [26] Disentangling bulk polymers from adsorbed polymers using the quartz crystal microbalance
    Gillissen, Jurriaan J. J.
    Jackman, Joshua A.
    Sut, Tun Naw
    Cho, Nam-Joon
    APPLIED MATERIALS TODAY, 2020, 18
  • [27] Detection of folic acid using a quartz crystal microbalance coated with molecularly imprinted polymer thin film
    Apodaca, Dahlia C.
    Pernites, Roderick B.
    Ponnapati, Ramakrishna
    Arco, Susan Dr
    Del Mundo, Florian R.
    Advincula, Rigoberto C.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239
  • [28] IMPRINTED CHIRAL MOLECULAR RECOGNITION IN DIPEPTIDE CRYSTALS IMMOBILIZED ON A QUARTZ-CRYSTAL MICROBALANCE
    OKAHATA, Y
    YASUNAGA, K
    OGURA, K
    JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1994, (04) : 469 - 470
  • [29] Molecularly imprinted polymer based quartz crystal microbalance sensor for the clinical detection of insulin
    Kartal, Fatma
    Cimen, Duygu
    Bereli, Nilay
    Denizli, Adil
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 97 : 730 - 737
  • [30] Molecularly imprinted polymer-coated quartz crystal microbalance for detection of biological hormone
    Kugimiya, A
    Takeuchi, T
    ELECTROANALYSIS, 1999, 11 (15) : 1158 - 1160