Calculating the Strength of Concrete Filled Steel Tube Columns of Solid and Ring Cross-Section

被引:5
|
作者
Krishan, A. L. [1 ]
Chernyshova, E. P. [1 ]
Sabirov, R. R. [1 ]
机构
[1] Nosov Magnitogorsk State Tech Univ, 38 Lenin Ave, Magnitogorsk 455000, Russia
关键词
concrete filled steel tube; preliminary pressed; nonlinear deformation model; three-axis tensely; concrete core; external steel holder;
D O I
10.1016/j.proeng.2016.07.186
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The authors have carried out experimental and theoretical studies of a new design of concrete filled steel tube (CFST) columns with pressed structure of concrete. The proposed design improvement idea is to make CFST columns with preliminary pressed concrete core. The bearing capacity of centrally compressed samples of CFST has increased by 20 divided by 25%. The obtained results are explained by a significant increase in the strength of concrete core in such preliminary compressed CFST samples due to the simultaneous manifestation of three effects: long-term compression of concrete mix, preliminary lateral compression of the concrete core and its work under the conditions of volume compression. The calculation of strength of CFST should be carried out on the basis of nonlinear reinforced concrete deformation model. Three-axis tensely-deformed conditions are assumed for the analytical description of work of the concrete core and the external steel holder. The basic dependencies, which allow to carry out such approximate calculations of the ultimate stress of compressed CFST, are resulted, too. (C) 2016 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:1878 / 1884
页数:7
相关论文
共 50 条
  • [21] Compressive strength of concrete-filled stainless steel tube stub columns
    Dai, Peng
    Yang, Lu
    Wang, Jie
    Zhou, Yuhang
    ENGINEERING STRUCTURES, 2020, 205
  • [22] Concrete filled steel tubes: determination and visualization of cross-section behavior
    Anwar, N
    Junaid, MT
    ADVANCES IN STRUCTURES, VOLS 1 AND 2, 2003, : 883 - 889
  • [23] Static test on axially compressed concrete filled CFRP-steel tubular columns with square cross-section
    Wang, Qingli
    Zhao, Weijuan
    Li, Jia
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2013, 34 (SUPPL.1): : 267 - 273
  • [24] Load-Bearing Capacity of Short Concrete-Filled Steel Tube Columns of Circular Cross Section
    Krishan, Anatolii Leonidovich
    Troshkina, Evgenia Anatolievna
    Rimshin, Vladimir Ivanovich
    Rahmanov, Viktor Alekseevich
    Kurbatov, Vladimir Leonidovich
    RESEARCH JOURNAL OF PHARMACEUTICAL BIOLOGICAL AND CHEMICAL SCIENCES, 2016, 7 (03): : 2518 - 2529
  • [25] Numerical analysis on fire performance of steel-reinforced concrete-filled steel tubular columns with square cross-section
    Mao, Wen-Jing
    Wang, Wen-Da
    Xian, Wei
    STRUCTURES, 2020, 28 : 1 - 16
  • [26] The interaction of steel tube and concrete core in concrete-filled steel tube columns
    Starossek, U.
    Falah, N.
    TUBULAR STRUCTURES XII, 2009, : 75 - +
  • [27] Strength of Concrete Filled Steel Tubular Columns
    Muhammad Naseem Baig
    樊健生
    聂建国
    Tsinghua Science and Technology, 2006, (06) : 657 - 666
  • [28] Strength of concrete filled steel tubular columns
    Department of Civil Engineering, Tsinghua University, Beijing 100084, China
    Tsinghua Sci. Tech., 2006, 6 (657-666):
  • [29] Finite Element Analysis on the Seismic Performance of Concrete-Filled Steel Tube Columns with a Multiple-Chamber Round-Ended Cross-Section
    Liu, Jing
    Yu, Wenzhuo
    Fang, Yawei
    Pan, Zimao
    Cao, Guohui
    BUILDINGS, 2024, 14 (04)