Diagnostics used in commissioning the IUCF Cooler Injector Synchrotron

被引:0
|
作者
Ball, MS [1 ]
Friesel, DL [1 ]
Hamilton, BJ [1 ]
机构
[1] Indiana Univ, Cyclotron Facil, Bloomington, IN 47408 USA
来源
关键词
D O I
10.1063/1.57027
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
Several new diagnostics systems were designed to aid in the commissioning of the IUCF Cooler Injection Synchrotron (CIS). Among them are a time of flight measurement system (ToF), a multi-wire profile monitor system (Harp) and a beam position monitor system (BPM). Pulsed beam from the 7 MeV linear accelerator is monitored using the ToF system. Several removable Harps are mounted in the injection beamline and ring which are instrumental for tuning ring injection and accumulation. BPMs are placed at the entrance and exit of the four ring dipole magnets to facilitate beam centering during injection and ramping. Fast and slow BPM displays are available to the operator for these functions. These diagnostics and their uses for CIS ring commissioning will be discussed.
引用
收藏
页码:428 / 431
页数:4
相关论文
共 50 条
  • [21] MULTIWIRE PROPORTIONAL CHAMBER FOR THE IUCF COOLER RING
    SOLBERG, K
    EADS, A
    GOODWIN, J
    PANCELLA, P
    MEYER, HO
    RINCKEL, T
    ROSS, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 281 (02): : 283 - 290
  • [22] Performance of a CW RFQ injector for the IUCF cyclotron
    Derenchuk, VP
    Anferov, V
    East, G
    Friesel, DL
    Hamm, RW
    Jones, WP
    Staples, J
    2005 IEEE PARTICLE ACCELERATOR CONFERENCE (PAC), VOLS 1-4, 2005, : 216 - 218
  • [23] H- operation of the cyclotron JULIC as injector for the cooler synchrotron COSY-Julich
    Bräutigam, W
    Brings, R
    Gebel, R
    Maier, R
    Schnase, A
    Jungwirth, H
    CYCLOTRONS AND THEIR APPLICATIONS 1998, 1999, : 654 - 657
  • [24] STATUS-REPORT ON THE IUCF COOLER STORAGE RING
    FRIESEL, DL
    ELLISON, TJ
    SCHWANDT, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1989, 40-1 : 927 - 933
  • [25] Commissioning of the 7 MeV H- linac injector for a 200 MeV proton synchrotron
    Wang, Zhongming
    Yang, Ye
    Liu, Wolong
    Wang, Baichuan
    Wang, Minwen
    Wang, Di
    Wang, Maocheng
    Lv, Wei
    Yan, Yihua
    Zhao, Mingtong
    Chen, Wei
    Qiu, Mengtong
    Ma, Pengfei
    Yu, Xudong
    Lei, Yu
    Zheng, Shuxin
    Du, Changtong
    Bi, Chongbo
    Zhang, Huayi
    Guan, Xialing
    Wang, Xuewu
    Xing, Qingzi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2022, 1040
  • [26] First tests of a CW RFQ injector for the IUCF cyclotrons
    Derenchuk, VP
    Anferov, V
    Friesel, DL
    Hamm, RW
    Jones, WP
    Staples, WP
    PROCEEDINGS OF THE 2003 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 2003, : 1563 - 1565
  • [27] Commissioning of the IUCF 7 MeV H- linac
    Friesel, DL
    Hamm, RW
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 2811 - 2813
  • [28] 12 MEV MICROTRON USED AS INJECTOR OF FRASCATI ELECTRON-SYNCHROTRON
    BIZZARRI, U
    VIGNATI, A
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A-NUCLEI PARTICLES AND FIELDS, 1970, 68 (03): : 513 - +
  • [29] Cooler synchrotron COSY
    Nucl Phys Sect A, 1-2 (395c):
  • [30] Cooler synchrotron COSY
    Maier, R
    Bechstedt, U
    Dietrich, J
    Martin, S
    Prasuhn, D
    Schnase, A
    Schneider, H
    Stockhorst, H
    Tolle, R
    NUCLEAR PHYSICS A, 1997, 626 (1-2) : 395C - 403C