Diagnostics used in commissioning the IUCF Cooler Injector Synchrotron

被引:0
|
作者
Ball, MS [1 ]
Friesel, DL [1 ]
Hamilton, BJ [1 ]
机构
[1] Indiana Univ, Cyclotron Facil, Bloomington, IN 47408 USA
来源
关键词
D O I
10.1063/1.57027
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
Several new diagnostics systems were designed to aid in the commissioning of the IUCF Cooler Injection Synchrotron (CIS). Among them are a time of flight measurement system (ToF), a multi-wire profile monitor system (Harp) and a beam position monitor system (BPM). Pulsed beam from the 7 MeV linear accelerator is monitored using the ToF system. Several removable Harps are mounted in the injection beamline and ring which are instrumental for tuning ring injection and accumulation. BPMs are placed at the entrance and exit of the four ring dipole magnets to facilitate beam centering during injection and ramping. Fast and slow BPM displays are available to the operator for these functions. These diagnostics and their uses for CIS ring commissioning will be discussed.
引用
收藏
页码:428 / 431
页数:4
相关论文
共 50 条
  • [1] Design and commissioning of beam position monitors in the IUCF cooler injector synchrotron
    Ball, MS
    Hamilton, BJ
    Bilodeau, D
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 2081 - 2083
  • [2] Status of the IUCF Cooler Injector Synchrotron
    Friesel, DL
    Lee, SY
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 935 - 937
  • [3] Status of the IUCF Cooler Injector Synchrotron
    Friesel, D.L.
    Lee, S.Y.
    Proceedings of the IEEE Particle Accelerator Conference, 1998, 1 : 935 - 937
  • [4] Polarized beam for the IUCF cooler injector synchrotron
    Derenchuk, VP
    Belov, AS
    POLARIZED GAS TARGETS AND POLARIZED BEAMS - SEVENTH INTERNATIONAL WORKSHOP, 1998, (421): : 422 - 426
  • [5] A pulsed ion source for the IUCF cooler injector synchrotron
    Derenchuk, VP
    Kupper, RR
    Petri, HR
    Berg, GPA
    Brown, RJ
    Fox, WR
    Friesel, DL
    Hunt, W
    Jones, WP
    Lozowski, WR
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 2737 - 2739
  • [6] Pulsed ion source for the IUCF Cooler Injector Synchrotron
    Derenchuk, V.P.
    Kupper, R.R.
    Petri, H.R.
    Berg, G.P.A.
    Brown, R.J.
    Fox, W.R.
    Friesel, D.L.
    Hunt, W.
    Jones, W.P.
    Lozowski, W.R.
    Proceedings of the IEEE Particle Accelerator Conference, 1998, 3 : 2737 - 2739
  • [7] Beam extraction system for the cooler injector synchrotron at IUCF
    Kang, X
    Berg, GPA
    Friesel, D
    Lee, SY
    Sloan, T
    PROCEEDINGS OF THE 1997 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: PLENARY AND SPECIAL SESSIONS ACCELERATORS AND STORAGE RINGS - BEAM DYNAMICS, INSTRUMENTATION, AND CONTROLS, 1998, : 264 - 266
  • [8] PROGRESS IN COMMISSIONING THE IUCF COOLER
    ELLISON, TJ
    JONES, WP
    COLLINS, JC
    FRIESEL, DL
    SCHWANDT, P
    SLOAN, T
    PROCEEDINGS OF THE 1989 IEEE PARTICLE ACCELERATOR CONFERENCE, VOLS 1-3: ACCELERATOR SCIENCE AND TECHNOLOGY, 1989, : 1608 - 1610
  • [9] Beam diagnostics in the Indiana University Cooler Injector Synchrotron
    Ball, M
    Derenchuk, V
    Hamilton, BJ
    BEAM INSTRUMENTATION - PROCEEDINGS OF THE SEVENTH WORKSHOP, 1997, (390): : 544 - 548
  • [10] CIS, a low energy injector for the IUCF cooler
    Friesel, DL
    Lee, SY
    PROCEEDINGS OF THE 1995 PARTICLE ACCELERATOR CONFERENCE, VOLS 1-5, 1996, : 336 - 338