Night Myopia Studied with an Adaptive Optics Visual Analyzer

被引:23
|
作者
Artal, Pablo [1 ]
Schwarz, Christina [1 ]
Canovas, Carmen [1 ]
Mira-Agudelo, Alejandro [1 ]
机构
[1] Univ Murcia, Lab Opt, Murcia, Spain
来源
PLOS ONE | 2012年 / 7卷 / 07期
关键词
WAVE-FRONT SENSOR; HUMAN EYE; OCULAR ABERRATIONS; ACCOMMODATION; COMPENSATION; PERFORMANCE;
D O I
10.1371/journal.pone.0040239
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose: Eyes with distant objects in focus in daylight are thought to become myopic in dim light. This phenomenon, often called "night myopia" has been studied extensively for several decades. However, despite its general acceptance, its magnitude and causes are still controversial. A series of experiments were performed to understand night myopia in greater detail. Methods: We used an adaptive optics instrument operating in invisible infrared light to elucidate the actual magnitude of night myopia and its main causes. The experimental setup allowed the manipulation of the eye's aberrations (and particularly spherical aberration) as well as the use of monochromatic and polychromatic stimuli. Eight subjects with normal vision monocularly determined their best focus position subjectively for a Maltese cross stimulus at different levels of luminance, from the baseline condition of 20 cd/m(2) to the lowest luminance of 22 x 10(-6) cd/m(2). While subjects performed the focusing tasks, their eye's defocus and aberrations were continuously measured with the 1050-nm Hartmann-Shack sensor incorporated in the adaptive optics instrument. The experiment was repeated for a variety of controlled conditions incorporating specific aberrations of the eye and chromatic content of the stimuli. Results: We found large inter-subject variability and an average of -0.8 D myopic shift for low light conditions. The main cause responsible for night myopia was the accommodation shift occurring at low light levels. Other factors, traditionally suggested to explain night myopia, such as chromatic and spherical aberrations, have a much smaller effect in this mechanism. Conclusions: An adaptive optics visual analyzer was applied to study the phenomenon of night myopia. We found that the defocus shift occurring in dim light is mainly due to accommodation errors.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] ACCOMMODATION AND NIGHT MYOPIA
    OTERO, JM
    AGUILAR, M
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1951, 41 (12) : 1061 - 1062
  • [22] ACCOMMODATION AND NIGHT MYOPIA
    TOUSEY, R
    KOOMEN, M
    SCOLNIK, R
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1953, 43 (10) : 926 - 927
  • [23] Night myopia and driving
    Charman, WN
    [J]. OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1996, 16 (06) : 474 - 485
  • [24] A STUDY OF NIGHT MYOPIA
    KOOMEN, M
    SCOLNIK, R
    TOUSEY, R
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1951, 41 (02) : 80 - 90
  • [25] Optics, evolution and myopia
    McMillan, N
    Slade, I
    [J]. Opto-Ireland 2005: Photonic Engineering, 2005, 5827 : 679 - 689
  • [26] Adaptive Illuminance Effects on Retinal Morphology and Refraction: A Comprehensive Study of Night Myopia
    Orduna-Hospital, Elvira
    Crespo-Castan, Cynthia
    Avila, Francisco J.
    Sanchez-Cano, Ana
    [J]. JOURNAL OF CLINICAL MEDICINE, 2024, 13 (01)
  • [27] CORRECTION OF NIGHT MYOPIA AND GLARE FOR NIGHT DRIVING
    FEJER, TP
    [J]. CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 1995, 30 (01): : 25 - 27
  • [28] NIGHT MYOPIA AT NIGHT AUTOMOBILE DRIVING LUMINANCES
    RICHARDS, OW
    [J]. AMERICAN JOURNAL OF OPTOMETRY AND ARCHIVES OF AMERICAN ACADEMY OF OPTOMETRY, 1967, 44 (08): : 517 - &
  • [29] EVOLUTIONARY APPROACH TO THE FORMATION OF MYOPIA: THE RESTRUCTURING OF THE VISUAL ANALYZER AS AN ADAPTATION TO THE SOCIAL AND CULTURAL CONDITIONS
    Dorosheva, E. A.
    [J]. EKSPERIMENTALNAYA PSIKHOLOGIYA, 2014, 7 (03): : 83 - 96
  • [30] AVES: an adaptive optics Visual Echelle Spectrograph for the VLT
    Pasquini, L
    Delabre, B
    Avila, G
    Bonaccini, D
    [J]. OPTICAL ASTRONOMICAL INSTRUMENTATION, PTS 1 AND 2, 1998, 3355 : 105 - 110