Reproducibility of functional aortic analysis using magnetic resonance imaging: the MESA

被引:29
|
作者
Noda, Chikara [1 ]
Venkatesh, Bharath Ambale [2 ]
Ohyama, Yoshiaki [1 ]
Liu, Chia-Ying [3 ]
Chamera, Elzbieta [1 ]
Redheuil, Alban [4 ,5 ]
Teixido-Tura, Gisela [6 ]
Chugh, Atul R. [7 ]
Wu, Colin O. [8 ]
Hundley, Gregory W. [9 ]
Bluemke, David A. [3 ]
Lima, Joao A. C. [1 ,10 ]
机构
[1] Johns Hopkins Univ, Dept Cardiol, Baltimore, MD 21287 USA
[2] Johns Hopkins Univ, Dept Radiol, Baltimore, MD 21287 USA
[3] NIH, Ctr Clin, Radiol & Imaging Sci, Bethesda, MD 20892 USA
[4] UPMC, Sorbonne Univ, Grp Hosp La Pitie Salpetriere, Paris, France
[5] ICAN Imaging Core Lab, Lab Dimagerie Fonct LIB INSERM UMR S 1146, Paris, France
[6] Vall Hebron Hosp, Barcelona, Spain
[7] Jewish Hosp, Dept Cardiol, Louisville, KY 40202 USA
[8] NHLBI, Off Biostat Res, NIH, Bethesda, MD 20892 USA
[9] Wake Forest Univ Hlth Sci, Dept Internal Med Cardiol, Winston Salem, NC 27157 USA
[10] Johns Hopkins Univ Hosp, Dept Med & Radiol, 600 North Wolfe St,Blalock 524D1, Baltimore, MD 21287 USA
关键词
aorta; reproducibility; pulse wave velocity; strain; MRI; phase contrast; PULSE-WAVE VELOCITY; CONTRAST MR-IMAGES; ARTERIAL STIFFNESS; HYPERTENSIVE PATIENTS; ATHEROSCLEROSIS MESA; GENERAL-POPULATION; HEART-FAILURE; DISTENSIBILITY; DISEASE; RISK;
D O I
10.1093/ehjci/jev215
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To assess the test-retest, intra- and inter-reader reliability of thoracic aorta measurements by magnetic resonance imaging (MRI). Methods and results Twenty-five participants underwent aortic MRI twice over 13 +/- 7 days. All aortic variables from baseline and repeat MR were analysed using a semi-automated method by the ARTFUN software. To assess the inter-study reproducibility of aortic variables, we calculated intraclass correlation coefficient (ICC) for individual aortic measurements. Intra-and inter-observer variability was also assessed using the baseline MR data. Mean ascending aortic strain had moderate inter-study reproducibility (11.53 +/- 6.44 vs. 10.55 +/- 6.64, P = 0.443, ICC = 0.53, P < 0.01). Mean descending aortic strain and arch pulse wave velocity (PWV) had good inter-study reproducibility (descending aortic strain: 8.65 +/- 5.30 vs. 8.35 +/- 5.26, P = 0.706, ICC = 0.74, P < 0.001; PWV: 9.92 +/- 4.18 vs. 9.94 +/- 4.55, P = 0.968, ICC = 0.77, P < 0.001, respectively). All aortic variables had excellent intra-and inter-observer reproducibility (intra-: ICC range, 0.87-0.99, inter-: ICC range, 0.56-0.99, respectively). Conclusion Inter-study reproducibility of all aortic variables was acceptable. Intra-and inter-observer reproducibility of all aortic variables was excellent. MRI can provide a repeatable method of measuring aortic structural and functional parameters.
引用
收藏
页码:909 / 917
页数:9
相关论文
共 50 条
  • [1] Improving functional magnetic resonance imaging reproducibility
    Pernet, Cyril
    Poline, Jean-Baptiste
    [J]. GIGASCIENCE, 2015, 4
  • [2] Reproducibility of aortic root measurements using cardiac magnetic resonance imaging: is this aortic root dilating?
    Mortensen, K. H.
    Taylor, A.
    Hughes, M. L.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 : 879 - 880
  • [3] REPRODUCIBILITY OF COMPLEX FUNCTIONAL MAGNETIC RESONANCE IMAGING EFFECTS
    Toepper, Max
    Sammer, Gebhard
    Bauer, Eva
    [J]. JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2016, 64 (09) : E62 - E62
  • [4] Scan reproducibility of magnetic resonance imaging assessment of aortic atherosclerosis burden
    Chan, SK
    Jaffer, FA
    Botnar, RM
    Kissinger, KV
    Goepfert, L
    Chuang, ML
    O'Donnell, CJ
    Levy, D
    Manning, WJ
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2001, 3 (04) : 331 - 338
  • [5] Reproducibility of a Ramping Protocol to Measure Cerebral Vascular Reactivity Using Functional Magnetic Resonance Imaging
    Evanoff, Nicholas G.
    Marlatt, Kara L.
    Geijer, Justin R.
    Mueller, Bryon A.
    Lim, Kelvin O.
    Dengel, Donald R.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 542 - 542
  • [6] Reproducibility of a ramping protocol to measure cerebral vascular reactivity using functional magnetic resonance imaging
    Evanoff, Nicholas G.
    Mueller, Bryon A.
    Marlatt, Kara L.
    Geijer, Justin R.
    Lim, Kelvin O.
    Dengel, Donald R.
    [J]. CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2020, 40 (03) : 183 - 189
  • [7] Reproducibility of human brain activity evoked by esophageal stimulation using functional magnetic resonance imaging
    Coen, Steven J.
    Gregory, Lloyd J.
    Yaguez, Lidia
    Amaro, Edson, Jr.
    Brammer, Mick
    Williams, Steven C. R.
    Aziz, Qasim
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-GASTROINTESTINAL AND LIVER PHYSIOLOGY, 2007, 293 (01): : G188 - G197
  • [8] Feasibility and reproducibility of functional magnetic resonance imaging in Medetomidine sedated rodents
    Kounev, Venelin J.
    Hyde, James
    Kern, Mark
    Sengupta, Jyoti
    Pawela, Christopher
    Prah, Douglas
    Paulson, Eric
    Shaker, Reza
    [J]. GASTROENTEROLOGY, 2006, 130 (04) : A441 - A442
  • [9] Agreement and reproducibility in identification of endometriosis using magnetic resonance imaging
    Saba, Luca
    Guerriero, Stefano
    Sulcis, Rosa
    Ajossa, Silvia
    Melis, Gianbenedetto
    Mallarini, Giorgio
    [J]. ACTA RADIOLOGICA, 2010, 51 (05) : 573 - 580
  • [10] Reproducibility of Magnetic Resonance Perfusion Imaging
    Zhang, Xiaomeng
    Pagel, Mark D.
    Baker, Amanda F.
    Gillies, Robert J.
    [J]. PLOS ONE, 2014, 9 (02):