Scan reproducibility of magnetic resonance imaging assessment of aortic atherosclerosis burden

被引:43
|
作者
Chan, SK
Jaffer, FA
Botnar, RM
Kissinger, KV
Goepfert, L
Chuang, ML
O'Donnell, CJ
Levy, D
Manning, WJ [1 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Harvard Thorndike Lab, Boston, MA 02215 USA
[2] Beth Israel Deaconess Med Ctr, Dept Radiol, Harvard Thorndike Lab, Boston, MA 02215 USA
[3] Massachusetts Gen Hosp, Dept Med, Div Cardiol, Boston, MA 02114 USA
[4] Philips Med Syst RMB, Best, Netherlands
[5] Natl Heart Lung & Blood Inst Framingham Heart Stu, Framingham, MA USA
关键词
aorta; atherosclerosis; magnetic resonance imaging; subclinical disease;
D O I
10.1081/JCMR-100108587
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Subclinical atherosclerosis precedes the onset of clinical disease by many years. Noninvasive magnetic resonance imaging (MRI) offers the opportunity to visualize and quantify atherosclerotic plaque. However, the reproducibility of MRI measurements of abdominal and thoracic aortic atherosclerosis has not been reported. Electrocardiogram-gated, T2-weighted, turbo spin echo MRI of the descending thoracic and abdominal aorta was performed on 16 subjects, comprising 10 subjects with multivessel coronary artery disease (CAD) and 6 subjects without angiographic CAD. Three identical MRIs were performed on each subject, with subject repositioning between the second and third scans. Aortic anatomic and plaque measurements were performed in a blinded fashion. Fourteen subjects (88%) had MRI evidence of atherosclerotic plaque on at least one image. Slice plaque burden, plaque area, and plaque perimeter were greater in the CAD group (52% vs. 9%, p = 0.002: 264 vs. 18 mm(2), p = 0.009; 159 vs. 15 mm, p = 0.006, respectively). Measurements of total aortic lumen area, lumen circumference, plaque area, and plaque perimeter correlated highly among the three scans (all r = 0.96, all p < 0.001). Measurements of slice-specific is aortic lumen area and lumen circumference also correlated highly (all r = 0.98, all p < 0.001). Correlations of slice-specific plaque area and plaque perimeter were significant (all p < 0.001) but less robust (r = 0.62-0.85). These data demonstrate that MRI is a reproducible technique for assessing aortic anatomy and total aortic atherosclerosis, but increased slice density should be considered if serial evaluation of slice-specific data is desired.
引用
收藏
页码:331 / 338
页数:8
相关论文
共 50 条
  • [1] Assessment and reproducibility of aortic atherosclerosis magnetic resonance imaging - Impact of 3-Tesla field strength and parallel imaging
    Maroules, Christopher D.
    McColl, Roderick
    Khera, Amit
    Peshock, Ronald M.
    [J]. INVESTIGATIVE RADIOLOGY, 2008, 43 (09) : 656 - 662
  • [2] Transesophageal magnetic resonance imaging of patients with aortic atherosclerosis
    Shunk, KA
    Atalar, E
    Rochitte, CE
    Lima, JAC
    [J]. CIRCULATION, 1999, 100 (18) : 24 - 24
  • [3] Reproducibility of functional aortic analysis using magnetic resonance imaging: the MESA
    Noda, Chikara
    Venkatesh, Bharath Ambale
    Ohyama, Yoshiaki
    Liu, Chia-Ying
    Chamera, Elzbieta
    Redheuil, Alban
    Teixido-Tura, Gisela
    Chugh, Atul R.
    Wu, Colin O.
    Hundley, Gregory W.
    Bluemke, David A.
    Lima, Joao A. C.
    [J]. EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2016, 17 (08) : 909 - 917
  • [4] Reproducibility of left atrial assessment in cardiac magnetic resonance imaging
    Alfuhied, A.
    Marrow, B.
    Gulsin, G.
    Steadman, C.
    McCann, G. P.
    Singh, A.
    [J]. EUROPEAN HEART JOURNAL, 2020, 41 : 240 - 240
  • [5] Cardiac magnetic resonance imaging for the assessment of aortic stenosis
    Singh, Anvesha
    McCann, Gerry P.
    [J]. HEART, 2019, 105 (06) : 489 - 497
  • [6] Reproducibility of aortic root measurements using cardiac magnetic resonance imaging: is this aortic root dilating?
    Mortensen, K. H.
    Taylor, A.
    Hughes, M. L.
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 : 879 - 880
  • [7] Imaging of atherosclerosis: magnetic resonance imaging
    Corti, Roberto
    Fuster, Valentin
    [J]. EUROPEAN HEART JOURNAL, 2011, 32 (14) : 1709 - U149
  • [8] Combined transesophageal and surface magnetic resonance imaging provides optimal imaging of aortic atherosclerosis
    Warren, WP
    Heath, S
    Lima, J
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 458A - 458A
  • [9] Magnetic resonance imaging of atherosclerosis
    Leiner, T
    Gerretsen, S
    Botnar, R
    Lutgens, E
    Cappendijk, V
    Kooi, E
    van Engelshoven, J
    [J]. EUROPEAN RADIOLOGY, 2005, 15 (06) : 1087 - 1099
  • [10] Magnetic resonance imaging of atherosclerosis
    T. Leiner
    S. Gerretsen
    R. Botnar
    E. Lutgens
    V. Cappendijk
    E. Kooi
    J. van Engelshoven
    [J]. European Radiology, 2005, 15 : 1087 - 1099