Shutdown dose rate assessment of the interspace components of wide angle viewing system diagnostic for ITER

被引:3
|
作者
Mota, F. [1 ]
Peneliau, Y. [2 ]
Catalan, J. P. [4 ]
Alguacil, J. [4 ]
Medrano, M. [1 ]
Rincon, E. [1 ]
Cabrera, S. [1 ]
Carrasco, R. [1 ]
Lapayese, F. [1 ]
Pastor, C. [1 ]
de la Pena, A. [1 ]
Pereira, A. [1 ]
Queral, V. [1 ]
Ramos, F. [1 ]
Rodriguez, C. [1 ]
Soleto, A. [1 ]
Letellier, L. [2 ]
Le Guern, F. [3 ]
Piqueras, J. J. [3 ]
机构
[1] CIEMAT, Lab Nacl Fus, Madrid 28040, Spain
[2] IRFM, CEA, F-13108 St Paul Les Durance, France
[3] F4E, Josep Pla 2,Torres Diagonal Litoral B3, Barcelona 08019, Spain
[4] ETSII UNED, Dept Ingn Energet, Calle Juan Rosal 12, Madrid 28040, Spain
关键词
ITER; WAVS; Diagnostic; Nuclear analysis; D1SUNED; VARIANCE REDUCTION; DESIGN;
D O I
10.1016/j.fusengdes.2021.112916
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Shutdown dose rate (SDDR) calculations have been performed to give support to the design of the Interspace (IS) VIS/IR WAVS diagnostic components of the Equatorial Port 12 (EP12), in the framework of the F4E-FPA-407 SG04 project. The Vis/IR WAVS comprises the viewing systems in four Equatorial Ports: 3, 9, 12 and 17, reminding that the present results are relative to the EP12 specifically. The Vis/IR WAVS is an optical diagnostic aimed at monitoring in visible and infrared radiation the ITER plasma facing components for machine protection. This paper describes the methodology used and shows the results obtained. The objective of the assessment is to evaluate whether the design meets the ALARA criteria in the IS area. In this work, once the materials have been selected to contribute as less as possible to the activation, the main criterion is that the contribution of all diagnostics installed in the port should not overcome the target of the biological dose rate of 100 mu Sv/h in the IS area after 106s of decay time. The main conclusion of the analysis is that the contribution of the VIS/IR WAVS IS components to the SDDR meets with the ALARA criterion in the IS. The contribution of the VIS/IR WAVS IS components to the SDDR in the IS, concerning the contribution of the whole ITER model, is about 9.6% in the left corridor and 5.5% in the right corridor. Besides, the percentage of contribution of the SS316L structure with respect to the total SDDR induced by the IS VIS/IR WAVS components is 99.3% in the left corridor and 99.5% in the right corridor. However, it has to be taken into account that these values have been obtained using a local model, therefore these values will be lower than the realistic values. Therefore, these values should be taken only as relative values.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Scoping Nuclear Analyses of Shielding Options and Shutdown Dose Rate Contributions in ITER TBSs
    Harb, M.
    Leichtle, D.
    Kim, B-Y
    Martins, J-P
    van der Laan, J. G.
    Bergman, J.
    Polunovskiy, E.
    Serikov, A.
    FUSION SCIENCE AND TECHNOLOGY, 2023, 79 (03) : 305 - 319
  • [42] ITER oriented neutronics benchmark experiments on neutron streaming and shutdown dose rate at JET
    Villari, R.
    Batistoni, P.
    Catalan, J. P.
    Colling, B.
    Croft, D.
    Fischer, U.
    Flammini, D.
    Fonnesu, N.
    Jones, L.
    Klix, A.
    Kos, B.
    Klosowski, M.
    Kodeli, I.
    Loreti, S.
    Moro, F.
    Naish, J.
    Obryk, B.
    Packer, L.
    Pereslavtsev, P.
    Pilotti, R.
    Popovichev, S.
    Sauvan, P.
    Stamatelatos, I. E.
    Vasilopoulou, T.
    Abhangi, M.
    Abreu, P.
    Aftanas, M.
    Afzal, M.
    Aggarwal, K. M.
    Aho-Mantila, L.
    Ahonen, E.
    Aints, M.
    Airila, M.
    Albanese, R.
    Alegre, D.
    Alessi, E.
    Aleynikov, P.
    Alfier, A.
    Alkseev, A.
    Allan, P.
    Almaviva, S.
    Alonso, A.
    Alper, B.
    Alsworth, I.
    Alves, D.
    Ambrosino, G.
    Ambrosino, R.
    Amosov, V.
    Andersson, F.
    Andersson Sunden, E.
    FUSION ENGINEERING AND DESIGN, 2017, 123 : 171 - 176
  • [43] Shutdown dose-rate assessment during the replacement of in-vessel components for a fusion DEMO reactor
    Someya, Youji
    Utoh, Hiroyasu
    Hiwatari, Ryoji
    Tanigawa, Hisashi
    Tobita, Kenji
    FUSION ENGINEERING AND DESIGN, 2017, 124 : 615 - 618
  • [44] The ITER Equatorial Visible/Infra-Red Wide Angle Viewing System: Status of design and R&D
    Salasca, Sophie
    Aumeunier, Marie-Helene
    Benoit, Fabrice
    Cantone, Bruno
    Corre, Yann
    Delchambre, Elise
    Ferlet, Marc
    Gauthier, Eric
    Guillon, Christophe
    van Houtte, Didier
    Keller, Delphine
    Labasse, Florence
    Larroque, Sebastien
    Loarer, Thierry
    Micolon, Frederic
    Peluso, Bertrand
    Proust, Maxime
    Blanchet, David
    Peneliau, Yannick
    Alonso, Javier
    de la Cal, Eduardo
    Hidalgo, Carlos
    Martin, Piedad
    Medrano, Mercedes
    Mota, Fernando
    Luis de Pablos, Jose
    Rios, Luis
    Rincon, Esther
    Vila, Rafael
    Manzanares, Ana
    Martin, Vincent
    Reichle, Roger
    Le Guern, Frederic
    FUSION ENGINEERING AND DESIGN, 2015, 96-97 : 932 - 937
  • [45] Final Design and Tests of the In-Vessel Shutter of the ITER Wide Angle Viewing System (WAVS) in Equatorial Port 12
    Guillon, C.
    Vives, S.
    Aumeunier, M. H.
    Delmas, E.
    Grosy, J.
    Lapcevic, N.
    Lefevre, N.
    Letellier, L.
    Proust, M.
    Le Guern, F.
    Piqueras, J.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2024, 52 (06) : 2207 - 2212
  • [46] Thermo-mechanical analysis of ITER first mirrors and its use for the ITER equatorial visible/infrared wide angle viewing system optical design
    Joanny, M.
    Salasca, S.
    Dapena, M.
    Cantone, B.
    Travere, J. M.
    Thellier, C.
    Ferme, J. J.
    Marot, L.
    Buravand, O.
    Perrollaz, G.
    Zeile, C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2012, 83 (10):
  • [47] CALCULATIONS OF SHUTDOWN DOSE RATE FOR THE TPR SPECTROMETER OF THE HIGH-RESOLUTION NEUTRON SPECTROMETER FOR ITER
    Wojcik-Gargula, A.
    Tracz, G.
    Scholz, M.
    RADIATION PROTECTION DOSIMETRY, 2018, 180 (1-4) : 75 - 79
  • [48] Operation and shutdown dose rate analysis of CFETR ECRH system
    Lu, Peng
    Wu, Qiuran
    Zhang, Liyuan
    Zheng, Yu
    Du, Hua
    Xu, Kun
    Liu, Songlin
    Wang, Xiaojie
    Huang, Jianjun
    Yu, Bin
    FUSION ENGINEERING AND DESIGN, 2020, 159
  • [49] Shutdown dose rate analysis of European test blanket modules shields in ITER Equatorial Port #16
    Juarez, Rafael
    Sauvan, Patrick
    Perez, Lucia
    Panayotov, Dobromir
    Vallory, Joelle
    Zmitko, Milan
    Poitevin, Yves
    Sanz, Javier
    FUSION ENGINEERING AND DESIGN, 2016, 109 : 1554 - 1558
  • [50] Rigorous MCNP based shutdown dose rate calculations: computational scheme, verification calculations and application to ITER
    Chen, Y
    Fischer, U