Use of 99Tcm-MIBI in the assessment of patients with suspected recurrent breast cancer

被引:18
|
作者
Cwikla, JB [1 ]
Buscombe, JR [1 ]
Parbhoo, SP [1 ]
Kelleher, SM [1 ]
Thakrar, DS [1 ]
Hinton, J [1 ]
Crow, J [1 ]
Deery, A [1 ]
Hilson, AJW [1 ]
机构
[1] CMKP Warszawa, Dept Nucl Med, PL-05400 Otwock, Poland
关键词
D O I
10.1097/00006231-199807000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A prospective trial was performed to assess the accuracy of Tc-99(m)-methoxyisobutyl isonitrile (Tc-99(m)-MIBI) scintimammography and X-ray mammography in 18 patients (mean age 58 years, range 46-79 years) with suspected recurrent breast cancer in the breast and/or loco-regional tissues. All patients had been diagnosed to have breast cancer 1-23 years before scintimammography. Two patients had undergone mastectomy, so that a total of 34 breasts were studied with X-ray mammography and with prone-lateral and anterior scintimammography. Any abnormalities on X-ray mammograms and scintimammograms were noted, as was any additional local or nodal uptake of Tc-99(m)-MIBI. The nature of any lesion seen with either modality, or in which there was a clinical suspicion of recurrence, was confirmed by cytological or histological examination of tissue samples. There were nine breasts with recurrent cancer in eight patients. X-ray mammography identified six of these cancers. Tc-99(m)-MIBI scintimammography identified eight of nine recurrent breast cancers (the one cancer not seen was positive on X-ray mammography). in the 26 breasts without cancer, two were reported as having changes consistent with cancer and one was reported equivocal. There were three false-positive and one equivocal scintimammograms. The accuracy of Tc-99(m)-MIBI scintimammography within the breast (85%) was similar to X-ray mammography (82%). Axillary lymph node recurrence occurred in five patients, four of whom were positive with Tc-99(m)-MIBI. An additional patient had focal uptake of Tc-99(m)-MIBI at the site of recurrent cancer on the anterior chest wall. In conclusion Tc-99(m)-MIBI scintimammography may provide useful complementary information in patients with suspected recurrence of cancer in the breast or loco-regional tissues. ((C) 1998 Lippincott-Raven Publishers).
引用
收藏
页码:649 / 655
页数:7
相关论文
共 50 条
  • [41] 甲旁亢患者99Tcm-MIBI显像异常二例
    朱瑞森
    陆汉魁
    马寄晓
    朱继芳
    陈立波
    罗全勇
    中华核医学杂志, 2005, (01) : 56 - 56
  • [42] Clinical value of 99Tcm-MIBI gated myocardial perfusion imaging in evaluating sarcoglycanopathy
    Fu, Peng
    Wei, Ling-Ge
    Hu, Jing
    Gao, Jian-Qing
    Jing, Jian-Min
    Liu, Xiao-Mei
    Huang, Jian-Min
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2019, 53 (04) : 265 - 270
  • [43] 定量99Tcm-MIBI心肌断层显像评估左室重构
    孙晓蓉
    乔俏
    李亚明
    韩春启
    中国临床医学影像杂志, 2001, (01) : 15 - 17
  • [44] 乳腺肿瘤摄取99Tcm-MIBI与预后因子的关系
    朱汇庆
    林祥通
    陈忠清
    张学平
    中华核医学杂志, 2002, (01) : 15 - 17
  • [45] 99Tcm-MIBI在检测乳腺癌中的作用
    川玲
    赵文锐
    国外医学(放射医学核医学分册), 2000, (04) : 155 - 157
  • [46] 99Tcm-MIBI心肌门控断层显像评价左室重构
    韩清华
    张承刚
    张中正
    胡光
    张水旺
    王陆建
    闫晓梅
    刘建中
    李思进
    韩树杰
    中华核医学杂志, 1999, (01) : 44 - 45
  • [47] 99Tcm-MIBI显像评价脑胶质瘤恶性程度
    李娜
    李亚明
    中华核医学杂志, 2004, (06) : 19 - 19
  • [48] 99Tcm-MIBI肿瘤显像对肺结节的诊断价值
    唐明灯
    佘志廉
    倪雷春
    林端瑜
    金星
    林爱珠
    中华核医学杂志, 2003, (06) : 39 - 40+78
  • [49] 99Tcm-MIBI平面显像诊断盆腔包块的价值
    张锦明
    田嘉禾
    焦鲁霞
    李亚里
    刘雁玲
    徐白萱
    刘自来
    张永贤
    张书文
    中华核医学杂志, 2000, (03) : 43 - 43
  • [50] 新型心肌灌注显像剂99Tcm-CO-MIBI与99Tcm-MIBI的药理学比较
    赵健东
    王金城
    米宏志
    郝桂阳
    朱霖
    同位素, 2005, (04) : 220 - 224