Use of 99Tcm-MIBI in the assessment of patients with suspected recurrent breast cancer

被引:18
|
作者
Cwikla, JB [1 ]
Buscombe, JR [1 ]
Parbhoo, SP [1 ]
Kelleher, SM [1 ]
Thakrar, DS [1 ]
Hinton, J [1 ]
Crow, J [1 ]
Deery, A [1 ]
Hilson, AJW [1 ]
机构
[1] CMKP Warszawa, Dept Nucl Med, PL-05400 Otwock, Poland
关键词
D O I
10.1097/00006231-199807000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A prospective trial was performed to assess the accuracy of Tc-99(m)-methoxyisobutyl isonitrile (Tc-99(m)-MIBI) scintimammography and X-ray mammography in 18 patients (mean age 58 years, range 46-79 years) with suspected recurrent breast cancer in the breast and/or loco-regional tissues. All patients had been diagnosed to have breast cancer 1-23 years before scintimammography. Two patients had undergone mastectomy, so that a total of 34 breasts were studied with X-ray mammography and with prone-lateral and anterior scintimammography. Any abnormalities on X-ray mammograms and scintimammograms were noted, as was any additional local or nodal uptake of Tc-99(m)-MIBI. The nature of any lesion seen with either modality, or in which there was a clinical suspicion of recurrence, was confirmed by cytological or histological examination of tissue samples. There were nine breasts with recurrent cancer in eight patients. X-ray mammography identified six of these cancers. Tc-99(m)-MIBI scintimammography identified eight of nine recurrent breast cancers (the one cancer not seen was positive on X-ray mammography). in the 26 breasts without cancer, two were reported as having changes consistent with cancer and one was reported equivocal. There were three false-positive and one equivocal scintimammograms. The accuracy of Tc-99(m)-MIBI scintimammography within the breast (85%) was similar to X-ray mammography (82%). Axillary lymph node recurrence occurred in five patients, four of whom were positive with Tc-99(m)-MIBI. An additional patient had focal uptake of Tc-99(m)-MIBI at the site of recurrent cancer on the anterior chest wall. In conclusion Tc-99(m)-MIBI scintimammography may provide useful complementary information in patients with suspected recurrence of cancer in the breast or loco-regional tissues. ((C) 1998 Lippincott-Raven Publishers).
引用
收藏
页码:649 / 655
页数:7
相关论文
共 50 条
  • [1] A comparison of 99Tcm-MDP and 99Tcm-MIBI in the detection of breast
    Wilczek, B
    von Schoultz, E
    Johansson, L
    Larsson, SA
    Jacobsson, H
    NUCLEAR MEDICINE COMMUNICATIONS, 2000, 21 (02) : 159 - 163
  • [2] 99Tcm-tetrofosmin scintimammography for detecting breast cancer:: a comparative study with 99Tcm-MIBI
    Horne, T
    Pappo, I
    Cohen-Pour, M
    Baumer, M
    Orda, R
    NUCLEAR MEDICINE COMMUNICATIONS, 2001, 22 (07) : 807 - 811
  • [3] Tc-99m MIBI in suspected recurrent breast cancer
    Cwikla, JB
    Kolasinska, AD
    Buscombe, JR
    Hilson, AJW
    CANCER BIOTHERAPY AND RADIOPHARMACEUTICALS, 2000, 15 (04) : 367 - 372
  • [4] The Impact of Tetrahydropalmatine on 99Tcm-MIBI Uptake of Human Breast Cancer MCF-7 Cell
    Yun, Jun
    Wang, Ling
    Yuan, Jia-Ying
    APPLIED MECHANICS AND MECHANICAL ENGINEERING II, PTS 1 AND 2, 2012, 138-139 : 1078 - +
  • [5] Verapamil decreases accumulation of 99Tcm-MIBI and 99Tcm-tetrofosmin in human breast cancer and soft tissue sarcoma cell lines
    Rodrigues, M
    Kalinowska, W
    Zielinski, Z
    Sinzinger, H
    NUCLEAR MEDICINE COMMUNICATIONS, 2001, 22 (06) : 645 - 650
  • [6] 99Tcm-MIBI scintimammography for the detection of breast malignancies:: The contribution of the count ratio to specificity
    Horne, T
    Pappo, I
    Cohenpour, M
    Mindlin, L
    Orda, R
    NUCLEAR MEDICINE COMMUNICATIONS, 1999, 20 (06) : 511 - 516
  • [7] 99Tcm-MIBI心肌显像检测“罪犯”血管
    栾兆生
    周雯
    彭勇
    苏玉文
    田嘉禾
    盖鲁粤
    孙志军
    中华核医学杂志, 2002, (02) : 28 - 29
  • [8] 99Tcm-MIBI与99Tcm(Ⅴ)-DMSA肺显像的对比研究
    李娟
    刘锦铭
    李经文
    刘保军
    中华核医学杂志, 2000, (05) : 38 - 39
  • [9] 99Tcm-tetrofosmin与99Tcm-MIBI心肌显像的对比研究
    赵葵
    陈鹏
    张芙荣
    沈文华
    中华核医学杂志, 2001, (04) : 37 - 39
  • [10] Investigation of perfusion reserve using 99Tcm-MIBI in the lower limbs of diabetic patients
    Çelen, YZ
    Zincirkeser, S
    Akdemir, I
    Yilmaz, M
    NUCLEAR MEDICINE COMMUNICATIONS, 2000, 21 (09) : 817 - 822