Cochlear implant device failure after cardioversion

被引:3
|
作者
Schild, C. [1 ]
Beck, R. [1 ]
Boedeker, C. C. [1 ]
Wesarg, T. [1 ]
Arndt, S. [1 ]
Aschendorff, A. [1 ]
Laszig, R. [1 ]
机构
[1] Univ Freiburg, Hals Nasen Ohren Klin, D-79106 Freiburg, Germany
关键词
Cochlear implant; Cardioversion; Defibrillation; Dysfunction; Reimplantation;
D O I
10.1007/s00106-011-2298-8
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Cochlear implantation has become the standard procedure for the treatment of severe to profound hearing loss, even in patients with underlying diseases. We report the case of a CI patient who underwent cardiac defibrillation, following which he reported a reduction in sound quality, a worsening of tinnitus, as well as headaches. An integrity test showed multiple electrode anomalies which could not be directly attributed to the cardioversion. We performed explantation and reimplantation of the CI. During the course of rehabilitation, the patient showed good results in speech comprehension. Since cardioversion, like any electrical monopolar treatment, may damage CI, it should be avoided in CI patients wherever possible. If it cannot be avoided, we strongly recommend removing the sound processor during treatment sessions. When device-related problems occur, the treatment of choice is reimplantation.
引用
收藏
页码:461 / +
页数:3
相关论文
共 50 条
  • [21] Cochlear Implant Reliability: Reporting of Device Failures
    O'Neill, Graham
    Tolley, Neil S.
    [J]. INDIAN JOURNAL OF OTOLARYNGOLOGY AND HEAD & NECK SURGERY, 2020, 72 (03) : 326 - 328
  • [22] RETRACTION: Cochlear implant device activation after 7 days in cochlear implant recipients (Retraction of Vol 35, Pg E 130, 2014)
    Diao, Mingfang
    Sun, Jianjun
    Tian, Fangjie
    Ding, Yili
    Wang, Yuqing
    [J]. EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2019, 276 (01) : 281 - 281
  • [23] Cochlear Implant Electrode Failure Secondary to Silicone Touch-Up During Device Manufacturing
    Shao, Weiru
    [J]. OTOLOGY & NEUROTOLOGY, 2013, 34 (07) : E72 - E75
  • [24] Hidden Electrode Failure in a Cochlear Implant User
    Gaertner, Lutz
    Buechner, Andreas
    Illg, Angelika
    Lenarz, Thomas
    [J]. LARYNGOSCOPE, 2021, 131 (04): : E1275 - E1278
  • [25] A case of cochlear implant with internal mechanical failure
    Ohno, Tsunehisa
    Iki, Takehiro
    Taniguchi, Aiko
    Fujiki, Nobuya
    Ohta, Kouzou
    Ito, Juichi
    [J]. ACTA OTO-LARYNGOLOGICA, 2007, 127 : 15 - 16
  • [26] Impedance Change as an Indicator of Cochlear Implant Failure
    Pisa, Justyn F. D.
    Almutairi, Walleed H.
    Mackie, Kristy
    Stangherlin, Daniela
    Sulkers, Jacob
    Hochman, Jordan B.
    [J]. OTOLOGY & NEUROTOLOGY, 2023, 44 (04) : E211 - E215
  • [27] Language outcomes after cochlear implant
    McGregor, Sophie
    Goldman, Ran D.
    [J]. CANADIAN FAMILY PHYSICIAN, 2022, 68 (10) : 737 - 738
  • [28] Outpatient rehabilitation after cochlear implant
    Fischer, M
    Bachor, E
    Bagus, H
    Bauschulte, S
    Greis, K
    Kampmann, D
    Streicher, B
    Jahnke, K
    [J]. HNO, 2000, 48 (11) : 832 - 838
  • [29] COCHLEAR IMPLANT AFTER RADICAL MASTOIDECTOMY
    SCRIVENER, BP
    GIBSON, WPR
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1987, 96 (01): : 19 - 20
  • [30] Cochlear implant after bacterial meningitis
    Bille, Jesper
    Ovesen, Therese
    [J]. PEDIATRICS INTERNATIONAL, 2014, 56 (03) : 400 - 405