Optimization and validation of a rapid high-resolution T1-w 3D FLASH water excitation MRI sequence for the quantitative assessment of articular cartilage volume and thickness

被引:81
|
作者
Glaser, C
Faber, S
Eckstein, F
Fischer, H
Springer, V
Heudorfer, L
Stammberger, T
Englmeier, KH
Reiser, M
机构
[1] Univ Munich, Inst Klin Radiol, D-81377 Munich, Germany
[2] Univ Munich, Anat Anstalt, Musculoskeletal Res Grp, D-80336 Munich, Germany
[3] GSF Neuherberg Ingolstadter, Medis Inst, D-85764 Oberschleissheim, Germany
[4] Fa Siemens, Erlangen, Germany
关键词
cartilage; quantification; MRI; osteoarthritis; follow up;
D O I
10.1016/S0730-725X(01)00292-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In view of follow up. survey and development of therapeutic strategies for osteoarthritis where cartilage deterioration plays an important role, a non invasive, reliable and quantitative assessment of the articular cartilage is desirable. The currently available high resolution T-1-weighted (T1-w) 3D FLASH pulse sequences with frequency selective fat suppression are very time consuming. We have I)optimized a high resolution T1-w 3D FLASH water excitation (WE) sequence for short acquisition time and cartilage visualization, and 2) validated this sequence for cartilage volume and thickness quantification. The spectral fat presaturation was replaced by selective water excitation. The flip angle of the WE sequence was optimized for the contrast to noise (C/N-cart) ratio of cartilage. Sagittal datasets (voxel size: 0.31 x 0.31 x 2 mm(3)) of the knees of nine healthy volunteers were acquired both, with the 3D FLASH WE (17.2/6.6/30 degrees) sequence (WE) and a previously validated 3D FLASH fat saturated (42/11/30 degrees) sequence (FS). For validation of the WE sequence, cartilage volume, mean and maximal cartilage thickness of the two sequences were compared. Reproducibility was assessed by calculating the coefficient of variation (COV %) of 4 consecutive WE data sets in the volunteers. The acquisition rime was reduced from 16 ' 30 " (FS) down to 7 ' 14 " for the WE sequence. Image contrast and visualization of the cartilage was very similar, but delineation of the basal layer of the cartilage was slightly improved with the WE sequence. A flip angle of 30 degrees provided the best C/N-cart ratios (WE). Reproducibility (COV) was between 1.9 and 5.9%. Cartilage volume and thickness agreed within 4% between FS and WE sequence. The WE sequence allows for rapid, valid and reproducible quantification of articular cartilage volume and thickness, prerequisites for follow-up examinations. The reduced acquisition time (50% of FS) enables routine clinical application and thus may contribute to a broader assessment of osteoarthritis. (C) 2001 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 30 条
  • [21] High-Resolution 3D versus Standard-Resolution 2D T2-Weighted Turbo Spin Echo MRI for the Assessment of Lumbar Nerve Root Compromise
    Sartoretti, Elisabeth
    Sartoretti, Thomas
    Schwenk, Arpad
    Alfieri, Alex
    Czell, David
    Wyss, Michael
    Wildi, Lukas
    Binkert, Christoph A.
    Sartoretti-Schefer, Sabine
    TOMOGRAPHY, 2022, 8 (01) : 257 - 266
  • [22] Comparison of high-resolution T1W 3D GRE (LAVA) with 2-point Dixon fat/water separation (FLEX) to T1W fast spin echo (FSE) in prostate cancer (PCa)
    Samji, Karim
    Alrashed, Abdulmohsen
    Shabana, Wael M.
    McInnes, Matthew D. F.
    Bayram, Ersin
    Schieda, Nicola
    CLINICAL IMAGING, 2016, 40 (03) : 407 - 413
  • [23] High-Resolution MRI of the Intraparotid Facial Nerve Based on a Microsurface Coil and a 3D Reversed Fast Imaging with Steady-State Precession DWI Sequence at 3T
    Chu, J.
    Zhou, Z.
    Hong, G.
    Guan, J.
    Li, S.
    Rao, L.
    Meng, Q.
    Yang, Z.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (08) : 1643 - 1648
  • [24] Accelerated 3D high-resolution T2-weighted breast MRI with deep learning constrained compressed sensing, comparison with conventional T2-weighted sequence on 3.0 T
    Yang, Fan
    Pan, Xuelin
    Zhu, Ke
    Xiao, Yitian
    Yue, Xun
    Peng, Pengfei
    Zhang, Xiaoyong
    Huang, Juan
    Chen, Jie
    Yuan, Yuan
    Sun, Jiayu
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 156
  • [25] Magnetization-prepared 2 Rapid Gradient-Echo MRI for B1 Insensitive 3D T1 Mapping of Hip Cartilage: An Experimental and Clinical Validation
    Schmaranzer, Florian
    Afacan, Onur
    Lerch, Till D.
    Kim, Young-Jo
    Siebenrock, Klaus A.
    Ith, Michael
    Cullmann, Jennifer L.
    Kober, Tobias
    Klarhoefer, Markus
    Tannast, Moritz
    Bixby, Sarah D.
    Novais, Eduardo N.
    Jung, Bernd
    RADIOLOGY, 2021, 299 (01) : 150 - 158
  • [26] High-Resolution Vessel Wall Magnetic Resonance Imaging of the Middle Cerebral Artery: Comparison of 3D CUBE T1-Weighted Sequence with and without Fat Suppression
    Wu, Yejun
    Li, Fangbing
    Wang, Yilin
    Hu, Tianxiang
    Xiao, Liang
    MEDICAL SCIENCE MONITOR, 2020, 26
  • [27] High-resolution multi-breath-held 3D volumetric T1 mapping acquisition: analysis of volume measurements of small structures using a respiratory motion phantom
    Keigo Kawaji
    Sui-Cheng Wang
    Akiko Tanaka
    Hui Wang
    Roberto Lang
    Amit R Patel
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [28] High-resolution contrast-enhanced vessel wall imaging in patients with suspected cerebral vasculitis: Prospective comparison of whole-brain 3D T1 SPACE versus 2D T1 black blood MRI at 3 Tesla
    Eiden, Sebastian
    Beck, Christopher
    Venhoff, Nils
    Elsheikh, Samer
    Ihorst, Gabriele
    Urbach, Horst
    Meckel, Stephan
    PLOS ONE, 2019, 14 (03):
  • [29] MR protocol optimization for hepatobiliary phase imaging with Gd-EOB-DTPA at 1.5 T: comparison between breath-hold T1-weighted and high-resolution navigated 3D T1-weighted sequences
    Picchi, Eliseo
    Ferrazzoli, Valentina
    Liberto, Valeria
    Toti, Luca
    Da Ros, Valerio
    Pucci, Noemi
    Minosse, Silvia
    Garaci, Francesco
    Di Giuliano, Francesca
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2024, 55 (01):
  • [30] Improved Blood Suppression of Motion-Sensitized Driven Equilibrium in High-Resolution Whole-Brain Vessel Wall Imaging: Comparison of Contrast-Enhanced 3D T1-Weighted FSE with Motion-Sensitized Driven Equilibrium and Delay Alternating with Nutation for Tailored Excitation
    Kim, D. J.
    Lee, H. -j.
    Baik, J.
    Hwang, M. J.
    Miyoshi, M.
    Kang, Y.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2022, 43 (12) : 1713 - 1718