Optimization and validation of a rapid high-resolution T1-w 3D FLASH water excitation MRI sequence for the quantitative assessment of articular cartilage volume and thickness

被引:81
|
作者
Glaser, C
Faber, S
Eckstein, F
Fischer, H
Springer, V
Heudorfer, L
Stammberger, T
Englmeier, KH
Reiser, M
机构
[1] Univ Munich, Inst Klin Radiol, D-81377 Munich, Germany
[2] Univ Munich, Anat Anstalt, Musculoskeletal Res Grp, D-80336 Munich, Germany
[3] GSF Neuherberg Ingolstadter, Medis Inst, D-85764 Oberschleissheim, Germany
[4] Fa Siemens, Erlangen, Germany
关键词
cartilage; quantification; MRI; osteoarthritis; follow up;
D O I
10.1016/S0730-725X(01)00292-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In view of follow up. survey and development of therapeutic strategies for osteoarthritis where cartilage deterioration plays an important role, a non invasive, reliable and quantitative assessment of the articular cartilage is desirable. The currently available high resolution T-1-weighted (T1-w) 3D FLASH pulse sequences with frequency selective fat suppression are very time consuming. We have I)optimized a high resolution T1-w 3D FLASH water excitation (WE) sequence for short acquisition time and cartilage visualization, and 2) validated this sequence for cartilage volume and thickness quantification. The spectral fat presaturation was replaced by selective water excitation. The flip angle of the WE sequence was optimized for the contrast to noise (C/N-cart) ratio of cartilage. Sagittal datasets (voxel size: 0.31 x 0.31 x 2 mm(3)) of the knees of nine healthy volunteers were acquired both, with the 3D FLASH WE (17.2/6.6/30 degrees) sequence (WE) and a previously validated 3D FLASH fat saturated (42/11/30 degrees) sequence (FS). For validation of the WE sequence, cartilage volume, mean and maximal cartilage thickness of the two sequences were compared. Reproducibility was assessed by calculating the coefficient of variation (COV %) of 4 consecutive WE data sets in the volunteers. The acquisition rime was reduced from 16 ' 30 " (FS) down to 7 ' 14 " for the WE sequence. Image contrast and visualization of the cartilage was very similar, but delineation of the basal layer of the cartilage was slightly improved with the WE sequence. A flip angle of 30 degrees provided the best C/N-cart ratios (WE). Reproducibility (COV) was between 1.9 and 5.9%. Cartilage volume and thickness agreed within 4% between FS and WE sequence. The WE sequence allows for rapid, valid and reproducible quantification of articular cartilage volume and thickness, prerequisites for follow-up examinations. The reduced acquisition time (50% of FS) enables routine clinical application and thus may contribute to a broader assessment of osteoarthritis. (C) 2001 Elsevier Science Inc. All rights reserved.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 30 条
  • [1] High-resolution 3D arteriography of chronic total peripheral occlusions using a T1-W turbo spin-echo sequence with inner-volume Imaging
    Sampath, Smita
    Raval, Amish N.
    Lederman, Robert J.
    McVeigh, Elliot R.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (01) : 40 - 49
  • [2] Validation of high-resolution water-excitation magnetic resonance imaging for quantitative assessment of thin cartilage layers
    Graichen, H
    Springer, V
    Flaman, T
    Stammberger, T
    Glaser, C
    Englmeier, KH
    Reiser, M
    Eckstein, F
    OSTEOARTHRITIS AND CARTILAGE, 2000, 8 (02) : 106 - 114
  • [3] Multiaxial 3D MRI of the Ankle Advanced High-Resolution Visualization of Ligaments, Tendons, and Articular Cartilage
    Fritz, Benjamin
    Netto, Cesar de Cesar
    Fritz, Jan
    CLINICS IN PODIATRIC MEDICINE AND SURGERY, 2024, 41 (04) : 685 - 706
  • [4] Multiaxial 3D MRI of the Ankle Advanced High-Resolution Visualization of Ligaments, Tendons, and Articular Cartilage
    Fritz, Benjamin
    de Cesar Netto, Cesar
    Fritz, Jan
    FOOT AND ANKLE CLINICS, 2023, 28 (03) : 529 - 550
  • [5] High-Resolution Maps of Magnetization Transfer with Inherent Correction for RF Inhomogeneity and T1 Relaxation Obtained from 3D FLASH MRI
    Helms, Gunther
    Dathe, Henning
    Kallenberg, Kai
    Dechent, Peter
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) : 1396 - 1407
  • [6] Intracranial Vessel Segmentation in 3D High-Resolution T1 Black-Blood MRI
    Elsheikh, S.
    Urbach, H.
    Reisert, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2022, 43 (12) : 1719 - 1721
  • [7] Articular cartilage grading of the knee: diagnostic performance of fat-suppressed 3D volume isotropic turbo spin-echo acquisition (VISTA) compared with 3D T1 high-resolution isovolumetric examination (THRIVE)
    Lee, Young Han
    Hahn, Seok
    Lim, Daekeon
    Suh, Jin-Suck
    ACTA RADIOLOGICA, 2017, 58 (02) : 190 - 196
  • [8] 3D grating-based X-ray phase-contrast computed tomography for high-resolution quantitative assessment of cartilage: An experimental feasibility study with 3T MRI, 7T MRI and biomechanical correlation
    Herzen, Julia
    Karampinos, Dimitrios C.
    Foehr, Peter
    Birnbacher, Lorenz
    Viermetz, Manuel
    Burgkart, Rainer
    Baum, Thomas
    Lohoefer, Fabian
    Wildgruber, Moritz
    Schilling, Franz
    Willner, Marian
    Marschner, Mathias
    Noel, Peter B.
    Rummeny, Ernst J.
    Pfeiffer, Franz
    Jungmann, Pia M.
    PLOS ONE, 2019, 14 (02):
  • [9] Phase-based fast 3D high-resolution quantitative T2 MRI in 7 T human brain imaging
    Seginer, Amir
    Schmidt, Rita
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [10] Phase-based fast 3D high-resolution quantitative T2 MRI in 7 T human brain imaging
    Amir Seginer
    Rita Schmidt
    Scientific Reports, 12