Sensor Performance Assessment for Terra and Aqua MODIS Using Unscheduled Lunar Observations

被引:4
|
作者
Wilson, Truman [1 ]
Angal, Amit [1 ]
Xiong, Xiaoxiong [2 ]
机构
[1] Sci Syst & Applicat Inc, 10210 Greenbelt Rd, Lanham, MD 20706 USA
[2] NASA, Sci & Explorat Directorate, GSFC, Greenbelt, MD 20771 USA
关键词
MODIS; lunar calibration; reflective solar bands; Moon; spatial characterization; Terra; Aqua; ON-ORBIT CALIBRATION; SCAN-ANGLE;
D O I
10.1117/12.2324873
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
The Moderate Resolution Imaging Spectroradiometer (MODIS) has been in operation for over 18 and 16 years on the Terra and Aqua spacecrafts, respectively. In order to maintain long-term calibration stability over the life of each mission, MODIS uses a set of on-board calibrators as well as observations of the Moon and selected Earth-view targets. The lunar observations nominally occur in a narrow phase angle range, 55 degrees - 56 degrees, and use scheduled spacecraft maneuvers in order to bring the Moon into alignment with the MODIS space-view port. These observations are used to help characterize the MODIS scan-mirror response versus scan-angle. In addition to these scheduled lunar observations, MODIS also views the Moon through the space-view port without a spacecraft maneuver when the geometry is appropriately aligned. This occurs over a wider phase angle range, between 51 degrees - 82 degrees degrees, than those of the scheduled moon observations. While the phase angle restriction of our scheduled observations provides consistency between the calibration events, the unscheduled Moon data can provide a valuable assessment of many calibration related investigations that use the Moon. In this paper, we compare the results of unscheduled versus scheduled lunar observations for several sensor calibration and performance assessments. These include the lunar calibration trending used to characterize the scan-mirror response versus scan angle and the electronic crosstalk correction of bands 27 - 30, which are currently used in the MODIS Level-1B data products, as well as sensor performance assessments such as band-to-band and detector-to-detector spatial registration.
引用
收藏
页数:16
相关论文
共 50 条
  • [41] Monitoring the Terra and Aqua MODIS RSB calibration using Scattered Light from the Nadir-port
    Angal, Amit
    Xiong, Xiaoxiong
    Geng, Xu
    Sun, Junqiang
    [J]. EARTH OBSERVING SYSTEMS XIX, 2014, 9218
  • [42] Validation of JAXA/MODIS Sea Surface Temperature in Water around Taiwan Using the Terra and Aqua Satellites
    Lee, Ming-An
    Tzeng, Mu-Tun
    Hosoda, Kohtaro
    Sakaida, Futoki
    Kawamura, Hiroshi
    Shieh, Wei-Juan
    Yang, Yih
    Chang, Yi
    [J]. TERRESTRIAL ATMOSPHERIC AND OCEANIC SCIENCES, 2010, 21 (04): : 727 - 736
  • [43] Terra and Aqua MODIS inter-comparison using LEO-GEO double difference method
    Chang, Tiejun
    Xiong, Xiaoxiong
    Angal, Amit
    [J]. SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XXII, 2018, 10785
  • [44] Cirrus observations using ground-based LIDAR and terra MODIS instrument
    Kulkarni, Padmavati
    Kumar, Y. Bhavani
    Prasantha, P. Vishnu
    Rao, D. Narayana
    Krishniah, M.
    [J]. REMOTE SENSING OF THE ATMOSPHERE AND CLOUDS, 2006, 6408
  • [45] Monitoring the On-Orbit Calibration of Terra MODIS Reflective Solar Bands Using Simultaneous Terra MISR Observations
    Angal, Amit
    Xiong, Xiaoxiong
    Wu, Aisheng
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2017, 55 (03): : 1648 - 1659
  • [46] Multiyear analysis of Terra/Aqua MODIS aerosol optical depth and ground observations over tropical urban region of Hyderabad, India
    Kharol, Shailesh Kumar
    Badarinath, K. V. S.
    Sharma, Anu Rani
    Kaskaoutis, D. G.
    Kambezidis, H. D.
    [J]. ATMOSPHERIC ENVIRONMENT, 2011, 45 (08) : 1532 - 1542
  • [47] Statistical analysis of diurnal variations in land surface temperature and the UHI effect using aqua and terra MODIS data
    Chauhan, Shivam
    Jethoo, Ajay Singh
    [J]. REMOTE SENSING LETTERS, 2023, 14 (05) : 503 - 511
  • [48] Urban vegetation land covers change detection using multi-temporal MODIS Terra/Aqua data
    Zoran, Maria A.
    Savastru, Roxana S.
    Savastru, Dan M.
    Dida, Adrian I.
    Ionescu, Ovidiu M.
    [J]. REMOTE SENSING FOR AGRICULTURE, ECOSYSTEMS, AND HYDROLOGY XV, 2013, 8887
  • [49] Intercomparison of On-Orbit Calibration Consistency Between Terra and Aqua MODIS Reflective Solar Bands Using the Moon
    Xiong, Xiaoxiong
    Sun, Junqiang
    Barnes, William
    [J]. IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2008, 5 (04) : 778 - 782
  • [50] Terra and Aqua MODIS Thermal Emissive Bands Calibration and RVS Stability Assessments Using an In Situ Ocean Target
    Diaz, Carlos L. Perez
    Xiong, Xiaoxiong
    Wu, Aisheng
    Chang, Tiejun
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60