Analysis of time series for non-invasive characterization of blood components and circulation patterns

被引:6
|
作者
Kraitl, J. [1 ]
Ewald, H. [1 ]
Gehring, H.
机构
[1] Univ Rostock, Inst Gen Elect Engn, D-18055 Rostock, Germany
关键词
Non-invasive; Photo-plethysmography; Hemoglobin; Wavelet transformation;
D O I
10.1016/j.nahs.2006.05.007
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Photo-plethysmography (PPG) is frequently used in research on microcirculation of blood. Usually PPG time series are analyzed by conventional linear methods, mainly Fourier analysis. These methods may not be optimal for the investigation of nonlinear effects of the heart circulation system like vasomotion, autoregulation, thermoregulation, breathing, heartbeat and vessels. PPG is a non-invasive procedure and takes minimal time to be carried out. The wavelet analysis of the PPG time series is a specific, sensitive nonlinear method for the in vivo identification of heart circulation patterns and human health status. This nonlinear analysis of PPG signals provides additional information which cannot be detected using conventional approaches. The wavelet analysis has been used to study healthy subjects and to characterize the health status of patients with a functional cutaneous microangiopathy which was associated with diabetic neuropathy. Additionally the fact that the absorption-coefficients mu(a) and scattering-coefficients mu(s) for blood differ at different wavelengths has been exploited and is used for calculation of the optical absorbability characteristics of human blood yielding information on blood components like hemoglobin and oxygen saturation. The measured PPG time signals and the ratio between the peak to peak pulse amplitudes are used for a measurement of these parameters. A newly developed PMD device has been introduced. The non-invasive in-vivo multi-spectral method is based on the radiation of monochromatic light, emitted by laser diodes, through an area of skin on the finger. Delays between the proportions of hemoglobin and plasma in the intravasal volume should be detected photo-electrically by signal-analytic evaluation of the signals. The computed nonlinear coefficients are used for the measurement and calculation of the relative hemoglobin concentration change. Results with this photometric method to measure changes in the hemoglobin concentration were demonstrated during measurements with a hemodynamic model and healthy subjects. The PMD is suitable for non-invasive continuous on-line monitoring of one or more biologic constituent values. The objective of this development is to reduce the dependence on measurement techniques which require that a sample of blood be withdrawn from the patient for in-vitro analysis. Any invasive method used on the patient to obtain blood is accompanied by problems of inconvenience, stress, and discomfort. The patient is also exposed to the normal risks of infection associated with such invasive methods. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:441 / 455
页数:15
相关论文
共 50 条
  • [21] Analysis of Invasive and Non-Invasive Meningiomas
    Croul, Sidney
    Salehi, Fateme
    Jalali, Shahrzad
    Burrell, Kelly
    Zadeh, Gelareh
    JOURNAL OF NEUROPATHOLOGY AND EXPERIMENTAL NEUROLOGY, 2011, 70 (06): : 537 - 537
  • [22] Design and Analysis of Non-Invasive Blood Glucose Levels Monitoring
    Sari, Marti Widya
    Luthfi, Muhtar
    2016 1ST INTERNATIONAL SEMINAR ON APPLICATION FOR TECHNOLOGY OF INFORMATION AND COMMUNICATION (ISEMANTIC): SCIENCE AND TECHNOLOGY FOR A BETTER FUTURE, 2016, : 134 - 137
  • [23] Non-invasive estimation of hemoglobin in blood using color analysis
    Srinivasan, K. S.
    Lakshmi, D.
    Ranganathan, H.
    Gunasekaran, N.
    2006 INTERNATIONAL CONFERENCE ON INDUSTRIAL AND INFORMATION SYSTEMS, VOLS 1 AND 2, 2006, : 547 - +
  • [24] Recording and analysis on non-invasive blood pressure in sleep studies
    Penzel, T
    Kohler, V
    Podszus, T
    Voigt, KH
    HOMEOSTASIS IN HEALTH AND DISEASE, 1995, 36 (5-6): : 304 - 315
  • [25] Derivative Spectroscopy in Non-Invasive Blood-Glucose Analysis
    Dontu, Vishnu
    2016 IEEE FIRST INTERNATIONAL CONFERENCE ON CONNECTED HEALTH: APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES (CHASE), 2016, : 350 - 351
  • [26] PTT Based Continuous Time Non-invasive Blood Pressure System
    Atef, Mohamed
    Li Xiyan
    Wang, Guoxing
    Lian, Yong
    2016 IEEE 59TH INTERNATIONAL MIDWEST SYMPOSIUM ON CIRCUITS AND SYSTEMS (MWSCAS), 2016, : 329 - 332
  • [27] Time series analysis of non-invasive hemodynamic monitoring data in neonates with hypoxic-ischemic encephalopathy
    Balog, Vera
    Vatai, Barbara
    Kovacs, Kata
    Szabo, Attila J.
    Szabo, Miklos
    Jermendy, Agnes
    FRONTIERS IN PEDIATRICS, 2023, 11
  • [28] Dimensions of the posterior cerebral circulation: an analysis based on advanced non-invasive imaging
    Rai, Ansaar T.
    Rodgers, Daniel
    Williams, Eric A.
    Hogg, Jeffery P.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2013, 5 (06) : 597 - 600
  • [29] Morphological Characteristics of the Posterior Cerebral Circulation: An Analysis Based on Non-Invasive Imaging
    Vitosevic, Filip
    Rasulic, Lukas
    Medenica, Svetlana Milosevic
    TURKISH NEUROSURGERY, 2019, 29 (05) : 625 - 630
  • [30] Non-Invasive Identification of Nutrient Components in Grain
    Farber, Charles
    Islam, A. S. M. Faridul
    Septiningsih, Endang M.
    Thomson, Michael J.
    Kurouski, Dmitry
    MOLECULES, 2021, 26 (11):