Analysis of time series for non-invasive characterization of blood components and circulation patterns

被引:6
|
作者
Kraitl, J. [1 ]
Ewald, H. [1 ]
Gehring, H.
机构
[1] Univ Rostock, Inst Gen Elect Engn, D-18055 Rostock, Germany
关键词
Non-invasive; Photo-plethysmography; Hemoglobin; Wavelet transformation;
D O I
10.1016/j.nahs.2006.05.007
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Photo-plethysmography (PPG) is frequently used in research on microcirculation of blood. Usually PPG time series are analyzed by conventional linear methods, mainly Fourier analysis. These methods may not be optimal for the investigation of nonlinear effects of the heart circulation system like vasomotion, autoregulation, thermoregulation, breathing, heartbeat and vessels. PPG is a non-invasive procedure and takes minimal time to be carried out. The wavelet analysis of the PPG time series is a specific, sensitive nonlinear method for the in vivo identification of heart circulation patterns and human health status. This nonlinear analysis of PPG signals provides additional information which cannot be detected using conventional approaches. The wavelet analysis has been used to study healthy subjects and to characterize the health status of patients with a functional cutaneous microangiopathy which was associated with diabetic neuropathy. Additionally the fact that the absorption-coefficients mu(a) and scattering-coefficients mu(s) for blood differ at different wavelengths has been exploited and is used for calculation of the optical absorbability characteristics of human blood yielding information on blood components like hemoglobin and oxygen saturation. The measured PPG time signals and the ratio between the peak to peak pulse amplitudes are used for a measurement of these parameters. A newly developed PMD device has been introduced. The non-invasive in-vivo multi-spectral method is based on the radiation of monochromatic light, emitted by laser diodes, through an area of skin on the finger. Delays between the proportions of hemoglobin and plasma in the intravasal volume should be detected photo-electrically by signal-analytic evaluation of the signals. The computed nonlinear coefficients are used for the measurement and calculation of the relative hemoglobin concentration change. Results with this photometric method to measure changes in the hemoglobin concentration were demonstrated during measurements with a hemodynamic model and healthy subjects. The PMD is suitable for non-invasive continuous on-line monitoring of one or more biologic constituent values. The objective of this development is to reduce the dependence on measurement techniques which require that a sample of blood be withdrawn from the patient for in-vitro analysis. Any invasive method used on the patient to obtain blood is accompanied by problems of inconvenience, stress, and discomfort. The patient is also exposed to the normal risks of infection associated with such invasive methods. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:441 / 455
页数:15
相关论文
共 50 条
  • [1] Review of Non-Invasive Analysis of Blood Components
    Cinar, Beyza
    Brueck, Rainer
    Keil, Alexander
    ADVANCES IN DIGITAL HEALTH AND MEDICAL BIOENGINEERING, VOL 1, EHB-2023, 2024, 109 : 119 - 126
  • [2] New ways of non-invasive measuring of blood circulation parameters
    Řiha, Kamil
    Chmelař, Milan
    Čiž, Radim
    WSEAS Transactions on Signal Processing, 2010, 6 (01): : 1 - 11
  • [3] Microvascular Circulation And Pulse Arrival Time Variability: Implications For Non-invasive Blood Pressure Devices
    Anderson, Cody
    Allen, Michael
    Benitez, Andres
    Jones, Matt
    Jin, Dong Gun
    Weimer, Kollyn
    Erol, Muhammet Enes
    Layec, Gwenael
    Park, Song-Young
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2024, 56 (10) : 48 - 48
  • [4] Time and frequency series combination for non-invasive regularity analysis of atrial fibrillation
    Vaya, Carlos
    Joaquin Rieta, Jose
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2009, 47 (07) : 687 - 696
  • [5] Time and frequency series combination for non-invasive regularity analysis of atrial fibrillation
    Carlos Vayá
    José Joaquín Rieta
    Medical & Biological Engineering & Computing, 2009, 47 : 687 - 696
  • [6] Linear and non-linear time series analysis in non-invasive physiological measurement.
    Carson, ER
    Leicester, HJ
    Roudsari, AV
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, : 489 - 495
  • [7] Non-invasive research of the condition of a microcirculatory channel of blood circulation system
    Korsunskij, V.M.
    Palagin, A.V.
    Romanov, V.A.
    Vojtovich, I.D.
    Upravlyayushchie Sistemy i Mashiny, 2002, (06): : 29 - 37
  • [8] Non-invasive Measurement Method of Blood Hematocrit for Management of Extracorporeal Circulation
    Ekuni, Shota
    Sankai, Yoshiyuki
    2014 IEEE/SICE INTERNATIONAL SYMPOSIUM ON SYSTEM INTEGRATION (SII), 2014, : 76 - 81
  • [9] Blood Biomarkers as a Non-Invasive Method for the Assessment of the State of the Fontan Circulation
    Wittczak, Andrzej
    Mazurek-Kula, Anna
    Banach, Maciej
    Piotrowski, Grzegorz
    Bielecka-Dabrowa, Agata
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (02)
  • [10] NON-INVASIVE ASSESSMENT OF CAROTID CIRCULATION
    WARNER, JS