Is surgical closure of patent foramen ovale the gold standard for treating interatrial shunts? An echocardiographic follow-up study

被引:19
|
作者
Schneider, B
Bauer, R
机构
[1] Kardiol Klin, Sana Kliniken Lubeck, D-23560 Lubeck, Germany
[2] Allgemeines Krankenhaus St Georg, Med Abt 2, Hamburg, Germany
关键词
D O I
10.1016/j.echo.2005.03.037
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Surgical closure of patent foramen ovale (PFO) has been considered definitive and the gold standard for preventing recurrent paradoxical embolism. However, in contrast to transcatheter PFO closure, patients undergoing operation have not systematically been re-evaluated for residual shunting. This study aimed to assess the efficacy of surgical PFO closure during follow-up by transesophageal echocardiography (TEE). Methods: Eleven adult patients with diagnosis of a PFO by contrast and/or color Doppler TEE underwent PFO closure by thoracotomy and direct suturing because of paradoxical embolism (n = 4), because of impending paradoxical embolism (n = 1), or during valve operation (n = 6). Results: TEE performed 5 days to 7 months after PFO closure revealed residual shunting in 8 of 11 patients (73%). The shunt size was unchanged in two patients. According to the color Doppler jet width across the atrial septum, the postoperative PFO diameter was smaller in 5 of the remaining 6 patients. Right-to-left shunting by contrast TEE, however, had newly developed (n = 1) or increased (n = 2) for patients with concomitant valve operation. Despite therapeutic anticoagulation a cerebrovascular event occurred in one patient 4 weeks after attempted PFO closure. The mechanism for persistent shunting was incomplete sealing of septum primum and septum secundum by the suture fine (n = 6) or a new iatrogenic defect of the fossa ovalis caused by surgical manipulation (n = 2). in two patients a second TEE after 12 and 41 months revealed enlargement of the PFO diameter. Conclusions: Surgical PFO closure can not be regarded as the gold standard for definitive treatment of interatrial shunts. Residual shunting present in a high proportion of patients may partly explain the recurrence of embolic events.
引用
收藏
页码:1385 / 1391
页数:7
相关论文
共 50 条
  • [11] Transcatheter closure of the patent foramen ovale in children: intermediate-term follow-up results
    Sel, Kutay
    Aykan, Hakan H.
    Duman, Derya
    Aypar, Ebru
    Ozkutlu, Suheyla
    Alehan, Dursun
    Karagoz, Tevfik
    CARDIOLOGY IN THE YOUNG, 2017, 27 (08) : 1545 - 1549
  • [12] Long term follow-up in a real-world study cohort after patent foramen ovale closure
    Hamm, C.
    Doerr, O.
    Haas, M.
    Schulz, L.
    Koerschgen, T.
    Nef, H. M.
    Keller, T.
    Fischer-Rasokat, U.
    Hamm, C. W.
    Liebetrau, C.
    EUROPEAN HEART JOURNAL, 2019, 40 : 2310 - 2310
  • [13] Follow-up in stroke patients with patent foramen ovale (PFO)
    Bayerle, U
    Brill, G
    Goerge, G
    Grotemeyer, KH
    STROKE, 2003, 34 (01) : 294 - 294
  • [14] Intracardiac echocardiographic guidance in transcatheter closure of patent foramen ovale: a feasibility study
    Girod, G.
    Meier, J. M.
    Delabays, A.
    Eeckhout, E.
    EUROPEAN HEART JOURNAL, 2005, 26 : 528 - 528
  • [15] Long term follow-up after percutaneous closure of patent foramen ovale for secondary prevention of stroke
    Guedeney, P.
    Hauguel-Moreau, M.
    Hage, G.
    Sabben, C.
    Deltour, S.
    Hammoudi, N.
    Molho, A.
    Mesnier, J.
    Alamowitch, S.
    Silvain, J.
    Montalescot, G.
    EUROPEAN HEART JOURNAL, 2019, 40 : 2333 - 2333
  • [16] Long-Term Follow-Up After Closure of Patent Foramen Ovale in Patients With Cryptogenic Embolism
    Wintzer-Wehekind, Jerome
    Alperi, Alberto
    Houde, Christine
    Cote, Jean-Marc
    Asmarats, Lluis
    Cote, Melanie
    Rodes-Cabau, Josep
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (03) : 278 - 287
  • [17] Transcatheter Patent Foramen Ovale Closure Is Effective in Alleviating Migraine in a 5-Year Follow-Up
    He, Yao-De
    Yan, Xiu-Li
    Qin, Chen
    Zhang, Peng
    Guo, Zhen-Ni
    Yang, Yi
    FRONTIERS IN NEUROLOGY, 2019, 10
  • [18] Prevention of recurrent cryptogenic stroke with percutaneous closure of patent foramen ovale; a follow-up study with magnetic resonance imaging
    Sunman, H.
    Ates, A.
    Yorgun, H.
    Canpolat, U.
    Sahiner, L.
    Kaya, B.
    Aytemir, K.
    Tokgozoglu, L.
    Kabakci, G.
    Oto, A.
    EUROPEAN HEART JOURNAL, 2013, 34 : 1002 - 1002
  • [19] Patent Foramen Ovale Closure Using a Bioabsorbable Closure Device Safety and Efficacy at 6-Month Follow-Up
    Van den Branden, Ben J.
    Post, Martijn C.
    Plokker, Herbert W.
    ten Berg, Jurrien M.
    Suttorp, Maarten J.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2010, 3 (09) : 968 - 973
  • [20] Longterm follow-up in patients with cerebral ischemia and patent foramen ovale
    Kunze, AK
    Wronka, T
    Lichy, C
    Ringleb, PA
    Winter, R
    Grau, AJ
    Brandt, T
    STROKE, 2000, 31 (01) : 299 - 299