摘要
The response of an NE213 scintillator has been determined for photons induced in the detector assembly by neutrons with energies between 1 MeV and 16 MeV. Coupled MCNP4A/EGS4 Monte Carlo simulations were compared and adjusted to experimental data. The complete set of response matrices for neutrons, photons and neutron induced photons was then used to determine the spectral neutron and photon fluence of Pu-239/C-13 and Am-241/Be-9 sources.
引用
下载
收藏
页码:627 / 630
页数:4
相关论文
共 50 条
  • [21] Unfolding the neutron spectrum of a NE213 scintillator using artificial neural networks
    Ido, A. Sharghi
    Bonyadi, M. R.
    Etaati, G. R.
    Shahriari, M.
    APPLIED RADIATION AND ISOTOPES, 2009, 67 (10) : 1912 - 1918
  • [22] Compact NE213 neutron spectrometer with high energy resolution for fusion applications
    Zimbal, A
    Reginatto, M
    Schuhmacher, H
    Bertalot, L
    Esposito, B
    Poli, F
    Adams, JM
    Popovichev, S
    Kiptily, V
    Murari, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2004, 75 (10): : 3553 - 3555
  • [23] TESTS ON A DIGITAL NEUTRON-GAMMA PULSE SHAPE DISCRIMINATOR WITH NE213
    BELL, ZW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1981, 188 (01): : 105 - 109
  • [24] On timing response improvement of an NE213 scintillator attached to two PMTs
    Zare, S.
    Ghal-Eh, N.
    Bayat, E.
    RADIATION PHYSICS AND CHEMISTRY, 2013, 90 : 6 - 10
  • [25] THE TEMPERATURE-DEPENDENCE OF PULSE SHAPE-DISCRIMINATION WITH NE213 SCINTILLATION-COUNTERS
    GALLOWAY, RB
    SHARAF, JM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 224 (1-2): : 181 - 184
  • [26] n-γ discrimination of NE213 scintillator
    Ye, Bangjiao
    Nanjyo, H.
    Kobayashi, T.
    Tsuno, S.
    Hasuko, K.
    He Jishu/Nuclear Techniques, 2003, 26 (07):
  • [27] GAMMA-RAY PULSE-HEIGHT RESPONSE OF AN NE-213 SCINTILLATION DETECTOR
    INGERSOLL, DT
    WEHRING, BW
    NUCLEAR INSTRUMENTS & METHODS, 1977, 147 (03): : 551 - 561
  • [28] THE LIGHT YIELD RESPONSE OF NE213 ORGANIC SCINTILLATORS TO CHARGED-PARTICLES RESULTING FROM NEUTRON INTERACTIONS
    MOUATASSIM, S
    COSTA, GJ
    GUILLAUME, G
    HEUSCH, B
    HUCK, A
    MOSZYNSKI, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 359 (03): : 530 - 536
  • [29] CHARACTERISTICS OF LARGE VOLUME NE213 NEUTRON COUNTERS FOR MUON CATALYZED FUSION INVESTIGATIONS
    BYSTRITSKY, VM
    WOZNIAK, J
    ZINOV, VG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 241 (2-3): : 532 - 538
  • [30] High count rate performance of NE213 scintillation detectors with associated pulse shape discrimination electronics
    Howarth, PJA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 376 (01): : 67 - 81