Consequences of different diagnostic 'gold standards' in test accuracy research:: Carpal Tunnel Syndrome as an example

被引:35
|
作者
Bachmann, LM
Jüni, P
Reichenbach, S
Ziswiler, HR
Kessels, AG
Vögelin, E
机构
[1] Univ Bern, Dept Social & Prevent Med, Bern, Switzerland
[2] Univ Zurich, Horten Ctr, Zurich, Switzerland
[3] Univ Bern, Inselspital, Dept Rheumatol & Clin Immunol, CH-3010 Bern, Switzerland
[4] Univ Bristol, Dept Social Med, MRC, Hlth Serv Res Collaborat, Bristol, Avon, England
[5] Maastricht Univ Hosp, Dept Clin Epidemiol, Maastricht, Netherlands
[6] Univ Bern, Inselspital, Dept Hand Surg, CH-3010 Bern, Switzerland
关键词
sensitivity and specificity; ROC curve; reference standards; carpal tunnel syndrome; ultrasonography;
D O I
10.1093/ije/dyi105
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Test accuracy studies assume the existence of a well-defined illness definition and clear-cut diagnostic gold standards or reference standards. However, in clinical reality illness definitions may be vague or a mere description of a set of manifestations, mostly clinical signs and symptoms. This can lead to disagreements among experts about the correct classification of an illness and the adequate reference standard. Using data from a diagnostic accuracy study in carpal tunnel syndrome, we explored the impact of different definitions on the estimated test accuracy and found that estimated test performance characteristics varied considerably depending on the chosen reference standard. In situations without a clear-cut illness definition, randomized controlled trials may be preferable to test accuracy studies for the evaluation of a novel test. These studies do not determine the diagnostic accuracy, but the clinical impact of a novel test on patient management and outcome.
引用
收藏
页码:953 / 955
页数:3
相关论文
共 50 条
  • [31] Evaluating the diagnostic utility of the flexion-compression test for carpal tunnel syndrome
    Denduluri, Sahitya K.
    Ford, Samuel
    Odum, Susan
    Geary, Michael B.
    Gaston, R. Glenn
    Loeffler, Bryan J.
    JOURNAL OF HAND AND MICROSURGERY, 2025, 17 (01)
  • [32] Diagnostic accuracy of sensory and motor tests for the diagnosis of carpal tunnel syndrome: a systematic review
    Armaghan Dabbagh
    Joy C. MacDermid
    Joshua Yong
    Tara L. Packham
    Luciana G. Macedo
    Maryam Ghodrati
    BMC Musculoskeletal Disorders, 22
  • [33] Diagnostic accuracy of sensory and motor tests for the diagnosis of carpal tunnel syndrome: a systematic review
    Dabbagh, Armaghan
    MacDermid, Joy C.
    Yong, Joshua
    Packham, Tara L.
    Macedo, Luciana G.
    Ghodrati, Maryam
    BMC MUSCULOSKELETAL DISORDERS, 2021, 22 (01)
  • [34] DIAGNOSTIC PARAMETERS OF SONOGRAPHY IN CARPAL TUNNEL SYNDROME
    Park, D. D.
    MUSCLE & NERVE, 2011, 44 (04) : 661 - 661
  • [35] Diagnostic testing in carpal tunnel syndrome - In reply
    Szabo, RM
    Slater, RR
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (01): : 184 - 184
  • [36] Diagnostic validity of ultrasonography in carpal tunnel syndrome
    Bueno-Gracia, Elena
    Haddad-Garay, Maria
    Tricas-Moreno, Jose M.
    Fanlo-Mazas, Pablo
    Malo-Urries, Miguel
    Estebanez-de-Miguel, Elena
    Hidalgo-Garcia, Cesar
    Ruiz de Escudero-Zapico, Alazne
    REVISTA DE NEUROLOGIA, 2015, 61 (01) : 1 - 6
  • [37] Evaluation of diagnostic procedures for carpal tunnel syndrome
    Tuck, NR
    Simper, D
    Schliesser, J
    Cramer, GD
    JNMS-JOURNAL OF THE NEUROMUSCULOSKELETAL SYSTEM, 2000, 8 (01): : 1 - 9
  • [38] The use of diagnostic ultrasound in carpal tunnel syndrome
    Wiesler, ER
    Chloros, GD
    Cartwright, MS
    Smith, BP
    Rushing, J
    Walker, FO
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2006, 31A (05): : 726 - 732
  • [39] The diagnostic conundrum of carpal tunnel syndrome - Reply
    Hadler, NM
    JOURNAL OF RHEUMATOLOGY, 1997, 24 (12) : 2485 - 2487
  • [40] The value of diagnostic testing in carpal tunnel syndrome
    Szabo, RM
    Slater, RR
    Farver, TB
    Stanton, DB
    Sharman, WK
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1999, 24A (04): : 704 - 714